Combined Tuned Mass Dampers for structural vibration control

被引:6
|
作者
Cao, Huong Quoc [1 ]
机构
[1] Univ Technol Sydney, Fac Engn & Informat Technol, Sch Mech & Mechatron Engn, Ultimo, NSW, Australia
关键词
Tuned mass damper; Tuned liquid column damper; Combined tuned mass damper; Passive vibration control; Multi -objective optimization; LIQUID COLUMN DAMPERS; RESPONSE CONTROL; WIND RESPONSE;
D O I
10.1016/j.ijnonlinmec.2023.104550
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
A Combined Tuned Mass Damper (CTMD), including a Tuned Liquid Column Damper (TLCD) integrated on the top of a traditional Tuned Mass Damper (TMD), is proposed to control vibrations of a Single Degree-Of-Freedom (SDOF) structure. This device can also be considered as a new hybrid type of tuned mass damper. The gained results from the parametric study indicate that the mass ratio between the TLCD and the TMD significantly affects the CTMD's effectiveness. In order to assess the structural vibration absorption capacity of this device, the effectiveness and robustness of an optimized CTMD are compared with those of optimum TMD and TLCD with the same weight as the CTMD. The numerical simulations show that the proposed CTMD provides a higher performance over a broader excitation frequency domain compared with both a conventional TMD and TLCD in mitigating structural vibration. Furthermore, the frequency response curve of the structure using the CTMD is relatively flat, whereas the frequency response curves of the structure with the TMD and TLCD remain a twopeak characteristic on the same frequency range considered. In another aspect, although the optimum CTMD is not more robust than the TMD or TLCD in resisting the change of the structural stiffness, it offers a wider range for choosing the frequency and damping ratio to aim at remaining similar efficiency to that of the optimized TMD (or TLCD). Therefore, a CTMD is much more robust than a single TMD or TLCD having equal weight to the CTMD. For parameters of the CTMD, the present research also indicates that the damping ratio of the TMD does not display an essential role in the CTMD. In contrast, although the TLCD mass is much smaller than the TMD mass, the appearance of the TLCD is very important in this device.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] TUNED MASS DAMPERS FOR BALCONY VIBRATION CONTROL
    SETAREH, M
    HANSON, RD
    [J]. JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1992, 118 (03): : 723 - 740
  • [2] Hysteretic tuned mass dampers for structural vibration mitigation
    Carpineto, Nicola
    Lacarbonara, Walter
    Vestroni, Fabrizio
    [J]. JOURNAL OF SOUND AND VIBRATION, 2014, 333 (05) : 1302 - 1318
  • [3] VIBRATION CONTROL EFFECTIVENESS OF PASSIVE TUNED MASS DAMPERS
    LIN, CC
    HU, CM
    WANG, JF
    HU, RY
    [J]. JOURNAL OF THE CHINESE INSTITUTE OF ENGINEERS, 1994, 17 (03) : 367 - 376
  • [4] Pendulum tuned mass dampers for floor vibration control
    Setareh, M
    Ritchey, JK
    Baxter, AJ
    Murray, TM
    [J]. JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2006, 20 (01) : 64 - 73
  • [5] VIBRATION CONTROL USING MULTIPLE TUNED MASS DAMPERS
    IGUSA, T
    XU, K
    [J]. JOURNAL OF SOUND AND VIBRATION, 1994, 175 (04) : 491 - 503
  • [6] Application of Tuned Mass Dampers for Structural Vibration Control: A State-of-the-art Review
    Rahimi, Fatemeh
    Aghayari, Reza
    Samali, Bijan
    [J]. CIVIL ENGINEERING JOURNAL-TEHRAN, 2020, 6 (08): : 1622 - 1651
  • [7] Optimization criteria for tuned mass dampers for structural vibration control under stochastic excitation
    Marano, Giuseppe Carlo
    Greco, Rita
    [J]. JOURNAL OF VIBRATION AND CONTROL, 2011, 17 (05) : 679 - 688
  • [8] STRUCTURAL CONTROL USING ACTIVE TUNED MASS DAMPERS
    ABDELROHMAN, M
    [J]. JOURNAL OF THE ENGINEERING MECHANICS DIVISION-ASCE, 1981, 107 (05): : 990 - 990
  • [9] VIBRATION CONTROL OF METAL SPATIAL STRUCTURES WITH TUNED MASS DAMPERS
    Yoshinaka, Susumu
    Kawaguchi, Ken'ichi
    Fujiwara, Jun
    Kishida, Akiko
    Yamakawa, Makoto
    [J]. JOURNAL OF THE INTERNATIONAL ASSOCIATION FOR SHELL AND SPATIAL STRUCTURES, 2023, 64 (02): : 95 - 108
  • [10] TUNED MASS DAMPERS TO CONTROL FLOOR VIBRATION FROM HUMANS
    SETAREH, M
    HANSON, RD
    [J]. JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1992, 118 (03): : 741 - 762