Performance Assessment of Four Grid-Connected Solar Photovoltaic Technologies under Similar Environmental Conditions in Nigeria

被引:2
|
作者
Owolabi, Abdulhameed Babatunde [1 ,2 ]
Yakub, Abdulfatai Olatunji [2 ]
Luqman, Raji [3 ,4 ]
Same, Noel Ngando [2 ]
Suh, Dongjun [2 ]
机构
[1] Kyungpook Natl Univ, Reg Leading Res Ctr Smart Energy Syst, Sangju 37224, South Korea
[2] Kyungpook Natl Univ, Dept Convergence & Fus Syst Engn, Sangju 37224, South Korea
[3] Fed Polytech Mubi, Sch Engn, Dept Mech Engn, Mubi, Adamawa State, Nigeria
[4] Fed Polytech Mubi, Ctr Entrepreneurship Dev, Mubi, Adamawa State, Nigeria
基金
新加坡国家研究基金会;
关键词
PV SYSTEM; INTERNATIONAL AIRPORT; MODULE TECHNOLOGIES; CLIMATIC CONDITIONS; POWER-PLANT; REGION; OPTIMIZATION; EFFICIENCY; VIABILITY; DRY;
D O I
10.1155/2023/9458440
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This research presents the performance of four grid-connected solar photovoltaic (PV) systems installed at the Adamawa State College of Health Technology, Mubi, Adamawa, Nigeria. The system consists of 3.5 kWp each of four different PV technologies. The mis and psi cells manufactured by China Sunergy and Conergy comprised 14 modules with a power capacity of 250 watts. The asi produced by Moser Baer consists of 10 modules, each having 350 watts, and the CIS manufactured by Solar Frontier has 20 modules, each having 175 watts. The PV was observed and recorded data from January 2022 to December 2022. The system performance was analyzed using eleven evaluation criteria. Based on the technical assessment of the systems for this location, the asi solar PV has the best annual performance. It demonstrated the most favorable performance ratio (PR) and capacity factor (CF) of 90.7% and 27.6%, respectively, when considering energy output, system yields, performance ratio, and capacity ratio. On the other hand, the msi system, manufactured by China Sunergy, exhibited significant efficiencies at both the panel and system levels, with values of 14.3% and 13.7%, respectively. This system stood out for its minimal overall losses, recorded at 7.78 hours, demonstrating superior efficiency and lower overall losses than the other systems under study. This study is critical because the result will provide valuable information to researchers in identifying the appropriate PV systems suitable for Nigeria. In addition, it will assist PV installers and manufacturers with updated information on the PV system with the best performance.
引用
收藏
页数:19
相关论文
共 50 条
  • [31] Dynamics of Grid-Connected Photovoltaic System at Fault Conditions
    Seo, H. C.
    Kim, C. H.
    Yoon, Y. M.
    Jung, C. S.
    T& D ASIA: 2009 TRANSMISSION & DISTRIBUTION CONFERENCE & EXPOSITION: ASIA AND PACIFIC, 2009, : 375 - +
  • [32] Testing the Technologies Demonstration Grid-Connected Photovoltaic Projects in Japan
    Hara, Ryoichi
    Kita, Hiroyuki
    Tanabe, Takayuki
    Sugihara, Hiroyuki
    Kuwayama, Akira
    Miwa, Shuya
    IEEE POWER & ENERGY MAGAZINE, 2009, 7 (03): : 77 - 85
  • [33] Economic assessment of grid-connected residential solar photovoltaic systems introduced under Romania's new regulation
    Cristea, Ciprian
    Cristea, Maria
    Birou, Iulian
    Tirnovan, Radu-Adrian
    RENEWABLE ENERGY, 2020, 162 : 13 - 29
  • [34] Performance Assessment of Grid-Connected Photovoltaic Inverters Based on Field Monitoring in India
    Pillai, Gobind
    Pearsall, Nicola
    Putrus, Ghanim
    Anand, R. S.
    Perumal, R. Pon
    2014 IEEE 5TH INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS FOR DISTRIBUTED GENERATION SYSTEMS (PEDG), 2014,
  • [35] Energy and economic efficiency performance assessment of a 28 kWp photovoltaic grid-connected system under desertic weather conditions in Algerian Sahara
    Sahouane, Nordine
    Dabou, Rachid
    Ziane, Abderrezzaq
    Necaibia, Ammar
    Bouraiou, Ahmed
    Rouabhia, Abdelkrim
    Mohammed, Blal
    RENEWABLE ENERGY, 2019, 143 : 1318 - 1330
  • [36] Design and Performance Analysis of Grid-Connected Solar Photovoltaic System with Performance Forecasting Approach (PFA)
    Deshmukh A.N.
    Chandrakar V.K.
    Journal of The Institution of Engineers (India): Series B, 2022, 103 (05) : 1521 - 1532
  • [37] The Technical and Economic Assessment of a Solar Rooftop Grid-Connected Photovoltaic System for a Dairy Farm
    Caglayan, Nuri
    ENERGIES, 2023, 16 (20)
  • [38] A techno-economic and environmental assessment of residential rooftop solar - Battery systems in grid-connected households in Lagos, Nigeria
    Udeani C.
    Jaramillo P.
    Williams N.J.
    Development Engineering, 2021, 6
  • [39] Experimental evaluation of the performance of grid-connected photovoltaic systems
    Chicco, G
    Napoli, R
    Spertino, F
    MELECON 2004: PROCEEDINGS OF THE 12TH IEEE MEDITERRANEAN ELECTROTECHNICAL CONFERENCE, VOLS 1-3, 2004, : 1011 - 1016
  • [40] MPPT Performance of a Grid-connected PV Inverter under Malaysian Conditions
    Azli, N. A.
    Salam, Z.
    Jusoh, A.
    Facta, M.
    Lim, B. C.
    Hossain, S.
    2008 IEEE 2ND INTERNATIONAL POWER AND ENERGY CONFERENCE: PECON, VOLS 1-3, 2008, : 457 - +