Dosimetric comparison of pencil beam scanning proton therapy with or without multi-leaf collimator versus volumetric-modulated arc therapy for treatment of malignant glioma

被引:2
|
作者
Miyata, Junya [1 ,2 ]
Tominaga, Yuki [1 ,3 ]
Kondo, Kazuto [2 ]
Sonoda, Yasuaki [2 ]
Hanazawa, Hideki [4 ]
Sakai, Mami [4 ]
Itasaka, Satoshi [4 ]
Oita, Masataka [5 ]
Kuroda, Masahiro [6 ]
机构
[1] Okayama Univ, Grad Sch Interdisciplinary Sci & Engn Hlth Syst, Okayama, Japan
[2] Kurashiki Cent Hosp, Dept Radiol Technol, Kurashiki, Okayama, Japan
[3] Osaka Proton Therapy Clin, Dept Radiotherapy, Med Co Hakuhokai, Osaka, Osaka, Japan
[4] Kurashiki Cent Hosp, Dept Radiat Oncol, Kurashiki, Okayama, Japan
[5] Okayama Univ, Fac Interdisciplinary Sci & Engn Hlth Syst, 1-1 Tsushimanaka,3 Chome,Kita Ku, Okayama, Okayama 7008530, Japan
[6] Okayama Univ, Grad Sch Hlth Sci, Okayama, Japan
关键词
Pencil beam scanning; Intensity-modulated proton therapy; Multi-leaf collimator; Volumetric-modulated arc therapy; Glioma; APERTURE SYSTEM; NORMAL TISSUE; RADIOTHERAPY; HEAD; DELINEATION; GUIDELINE; ADULTS; ORGANS; BRAIN; RISK;
D O I
10.1016/j.meddos.2023.01.008
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
This study aimed to examine the dosimetric effect of intensity-modulated proton therapy (IMPT) with a multi-leaf collimator (MLC) in treating malignant glioma. We compared the dose distribution of IMPT with or without MLC (IMPTMLC + or IMPTMLC-, respectively) using pencil beam scanning and volumetric -modulated arc therapy (VMAT) in simultaneous integrated boost (SIB) plans for 16 patients with malig-nant gliomas. High-and low-risk target volumes were assessed using D 2% , V 90% , V 95% , homogeneity index (HI), and conformity index (CI). Organs at risk (OARs) were evaluated using the average dose (Dmean) and D 2% . Furthermore, the dose to the normal brain was evaluated using from V5Gy to V40Gy at 5 Gy intervals. There were no significant differences among all techniques regarding V 90% , V 95% , and CI for the targets. HI and D 2% for IMPTMLC + and IMPTMLC-were significantly superior to those for VMAT ( p < 0.01). The Dmean and D 2% of all OARs for IMPTMLC + were equivalent or superior to those of other techniques. Regarding the normal brain, there was no significant difference in V40Gy among all techniques whereas V5Gy to V35Gy in IMPTMLC + were significantly smaller than those in IMPTMLC-(with differences ranging from 0.45% to 4.80%, p < 0.05) and VMAT (with differences ranging from 6.85% to 57.94%, p < 0.01). IMPTMLC + could reduce the dose to OARs, while maintaining target coverage compared to IMPTMLC-and VMAT in treating malignant glioma.(c) 2023 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:105 / 112
页数:8
相关论文
共 50 条
  • [21] Dosimetric comparison of hybrid volumetric-modulated arc therapy, volumetric-modulated arc therapy, and intensity-modulated radiation therapy for left-sided early breast cancer
    Lin, Jia-Fu
    Yeh, Dah-Cherng
    Yeh, Hui-Ling
    Chang, Chen-Fa
    Lin, Jin-Ching
    MEDICAL DOSIMETRY, 2015, 40 (03) : 262 - 267
  • [22] Influence of multi-leaf collimator leaf width in radiosurgery via volumetric modulated arc therapy and 3D dynamic conformal arc therapy
    Serna, Alfredo
    Puchades, Vicente
    Mata, Fernando
    Ramos, David
    Alcaraz, Miguel
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (03): : 293 - 296
  • [23] Comparison of dosimetries of carbon-ion pencil beam scanning, proton pencil beam scanning and volumetric modulated arc therapy for locally recurrent rectal cancer
    Mori, Shinichiro
    Bhattacharyya, Tapesh
    Furuichi, Wataru
    Tohyama, Naoki
    Nomoto, Akihiro
    Shinoto, Makoto
    Takiyama, Hirotoshi
    Yamada, Shigeru
    JOURNAL OF RADIATION RESEARCH, 2023, 64 (01) : 162 - 170
  • [24] Dosimetric Effect of Multi-Leaf Collimator Transmission On Intensity-Modulated Radiation Therapy
    Yang, R.
    Wang, J.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [25] Dosimetric Comparison of Automated Non-Coplanar Volumetric-Modulated Arc Therapy and Intensity-Modulated Proton Therapy in Angiosarcoma of the Scalp
    Inui, S.
    Tomita, N.
    Takaoka, T.
    Ueda, Y.
    Ohira, S.
    Tsuchiya, T.
    Miyazaki, M.
    Nishio, T.
    Koizumi, M.
    Konishi, K.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2023, 117 (02): : E675 - E675
  • [26] Dosimetric Comparison of the Newest Version Tomotherapy, Volumetric-Modulated Arc Therapy, and Intensity-Modulated Proton Therapy Plans for Angiosarcoma of the Scalp
    Mizuno, T.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E10 - E10
  • [27] Dosimetric Comparison of Uniform Scanning Proton Therapy, Helical Tomotherapy, and Volumetric Modulated Arc Therapy in the Treatment of Bilateral Orbital Lymphoma
    Crew, J. B.
    James, J. A.
    Thornton, A. F.
    Gautam, A.
    Sullivan, M.
    Tasson, A.
    Wolanski, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S806 - S807
  • [28] A Dosimetric Comparison of Volumetric-Modulated Arc Therapy to Intensity-Modulated Radiation Therapy in the Treatment of Locally Advanced Rectal Carcinoma
    Eldebawy E.
    Rashed Y.A.
    AlKhaldi M.
    Day E.
    Iranian Journal of Medical Physics, 2020, 17 (06) : 374 - 379
  • [29] The Effect of Multileaf Collimator Leaf Width on the Quality of Volumetric-Modulated Arc Therapy Stereotactic Radiosurgery Treatment Plans
    Laoui, S.
    Kuo, J. V.
    Al-Ghazi, M.
    Roa, D. E.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E682 - E683
  • [30] Treatment planning comparison of volumetric modulated arc therapy employing a dual-layer stacked multi-leaf collimator and helical tomotherapy for cervix uteri
    S. Panda
    J. Swamidas
    S. Chopra
    A. Mangaj
    A. Fogliata
    P. Kupelian
    J. P. Agarwal
    L. Cozzi
    Radiation Oncology, 15