Dosimetric comparison of pencil beam scanning proton therapy with or without multi-leaf collimator versus volumetric-modulated arc therapy for treatment of malignant glioma

被引:2
|
作者
Miyata, Junya [1 ,2 ]
Tominaga, Yuki [1 ,3 ]
Kondo, Kazuto [2 ]
Sonoda, Yasuaki [2 ]
Hanazawa, Hideki [4 ]
Sakai, Mami [4 ]
Itasaka, Satoshi [4 ]
Oita, Masataka [5 ]
Kuroda, Masahiro [6 ]
机构
[1] Okayama Univ, Grad Sch Interdisciplinary Sci & Engn Hlth Syst, Okayama, Japan
[2] Kurashiki Cent Hosp, Dept Radiol Technol, Kurashiki, Okayama, Japan
[3] Osaka Proton Therapy Clin, Dept Radiotherapy, Med Co Hakuhokai, Osaka, Osaka, Japan
[4] Kurashiki Cent Hosp, Dept Radiat Oncol, Kurashiki, Okayama, Japan
[5] Okayama Univ, Fac Interdisciplinary Sci & Engn Hlth Syst, 1-1 Tsushimanaka,3 Chome,Kita Ku, Okayama, Okayama 7008530, Japan
[6] Okayama Univ, Grad Sch Hlth Sci, Okayama, Japan
关键词
Pencil beam scanning; Intensity-modulated proton therapy; Multi-leaf collimator; Volumetric-modulated arc therapy; Glioma; APERTURE SYSTEM; NORMAL TISSUE; RADIOTHERAPY; HEAD; DELINEATION; GUIDELINE; ADULTS; ORGANS; BRAIN; RISK;
D O I
10.1016/j.meddos.2023.01.008
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
This study aimed to examine the dosimetric effect of intensity-modulated proton therapy (IMPT) with a multi-leaf collimator (MLC) in treating malignant glioma. We compared the dose distribution of IMPT with or without MLC (IMPTMLC + or IMPTMLC-, respectively) using pencil beam scanning and volumetric -modulated arc therapy (VMAT) in simultaneous integrated boost (SIB) plans for 16 patients with malig-nant gliomas. High-and low-risk target volumes were assessed using D 2% , V 90% , V 95% , homogeneity index (HI), and conformity index (CI). Organs at risk (OARs) were evaluated using the average dose (Dmean) and D 2% . Furthermore, the dose to the normal brain was evaluated using from V5Gy to V40Gy at 5 Gy intervals. There were no significant differences among all techniques regarding V 90% , V 95% , and CI for the targets. HI and D 2% for IMPTMLC + and IMPTMLC-were significantly superior to those for VMAT ( p < 0.01). The Dmean and D 2% of all OARs for IMPTMLC + were equivalent or superior to those of other techniques. Regarding the normal brain, there was no significant difference in V40Gy among all techniques whereas V5Gy to V35Gy in IMPTMLC + were significantly smaller than those in IMPTMLC-(with differences ranging from 0.45% to 4.80%, p < 0.05) and VMAT (with differences ranging from 6.85% to 57.94%, p < 0.01). IMPTMLC + could reduce the dose to OARs, while maintaining target coverage compared to IMPTMLC-and VMAT in treating malignant glioma.(c) 2023 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:105 / 112
页数:8
相关论文
共 50 条
  • [1] Quantification of Treatment Plan Deliverability in Breast Volumetric-modulated Arc Therapy With Agility Multi-leaf Collimator
    Oh, Do Hoon
    Choi, Jin Hwa
    Ryu, Hyejo
    Chun, Minsoo
    IN VIVO, 2024, 38 (05): : 2254 - 2260
  • [2] Influence of multi-leaf collimator leaf transmission on head and neck intensity-modulated radiation therapy and volumetric-modulated arc therapy planning
    Sasaki, Motoharu
    Tominaga, Masahide
    Kamomae, Takeshi
    Ikushima, Hitoshi
    Kitaoka, Motonori
    Bando, Ryota
    Sakuragawa, Kanako
    Oita, Masataka
    JAPANESE JOURNAL OF RADIOLOGY, 2017, 35 (09) : 511 - 525
  • [3] Influence of multi-leaf collimator leaf transmission on head and neck intensity-modulated radiation therapy and volumetric-modulated arc therapy planning
    Motoharu Sasaki
    Masahide Tominaga
    Takeshi Kamomae
    Hitoshi Ikushima
    Motonori Kitaoka
    Ryota Bando
    Kanako Sakuragawa
    Masataka Oita
    Japanese Journal of Radiology, 2017, 35 : 511 - 525
  • [4] Clinical significance of multi-leaf collimator positional errors for volumetric modulated arc therapy
    Oliver, Mike
    Gagne, Isabelle
    Bush, Karl
    Zavgorodni, Sergei
    Ansbacher, Will
    Beckham, Wayne
    RADIOTHERAPY AND ONCOLOGY, 2010, 97 (03) : 554 - 560
  • [5] Evaluation of dosimetric effect caused by slowing with multi-leaf collimator (MLC) leaves for volumetric modulated arc therapy (VMAT)
    Xu, Zhengzheng
    Wang, Iris Z.
    Kumaraswamy, Lalith K.
    Podgorsak, Matthew B.
    RADIOLOGY AND ONCOLOGY, 2016, 50 (01) : 121 - 128
  • [6] Dosimetric comparison of volumetric modulated arc therapy and proton pencil beam scanning technique under deep inspiration breath hold
    Chen, J.
    Shen, Y. L.
    Tsai, P. F.
    Lee, S. H.
    Wang, P. I.
    Chang, F.
    Liu, Y. C.
    Chang, J. T. C.
    EUROPEAN JOURNAL OF CANCER, 2015, 51 : S126 - S126
  • [7] Intensity-modulated radiotherapy, coplanar volumetric-modulated arc, therapy, and noncoplanar volumetric-modulated arc therapy in, glioblastoma: A dosimetric comparison
    Hou, Yong
    Zhang, Yan
    Liu, Zhen
    Yv, Lili
    Liu, Kun
    Tian, Xiufang
    Lv, Yajuan
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2019, 187
  • [8] Analysis of Multi-Leaf Collimator Leaf Position Errors in Volumetric Modulated Arc Therapy for Nasopharyngeal Carcinoma
    Li, C.
    Yin, Y.
    MEDICAL PHYSICS, 2016, 43 (06) : 3514 - 3514
  • [9] Hazards of a Tungsten Multi-Leaf Collimator in Proton Beam Therapy
    Moskvin, V.
    Cheng, C.
    Das, I.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [10] Validation of pencil beam scanning proton therapy with multi-leaf collimator calculated by a commercial Monte Carlo dose engine
    Tominaga, Yuki
    Sakurai, Yusuke
    Miyata, Junya
    Harada, Shuichi
    Akagi, Takashi
    Oita, Masataka
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (12):