Influence of multi-leaf collimator leaf transmission on head and neck intensity-modulated radiation therapy and volumetric-modulated arc therapy planning

被引:0
|
作者
Motoharu Sasaki
Masahide Tominaga
Takeshi Kamomae
Hitoshi Ikushima
Motonori Kitaoka
Ryota Bando
Kanako Sakuragawa
Masataka Oita
机构
[1] Tokushima University Hospital,Department of Radiological Technology
[2] Tokushima University Graduate School,Department of Therapeutic Radiology, Institute of Biomedical Sciences
[3] Nagoya University Graduate School of Medicine,Department of Therapeutic Radiology
[4] Kagawa University Hospital,Department of Radiological Technology
[5] Okayama University,Department of Radiological Technology, Graduate School of Health Sciences
来源
关键词
Multi-leaf collimator; Intensity-modulated radiation therapy; Volumetric-modulated arc therapy; Head and neck cancer;
D O I
暂无
中图分类号
学科分类号
摘要
The aim of this study was to quantify the effect of multi-leaf collimators (MLCs) with different leaf widths on the planning of intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT). Toward this objective, dose transmission through a high-definition 120-leaf MLC (HD120MLC) and 120-leaf Millennium MLC (M120MLC) was investigated, using it with a test case and clinical case studies. In test case, studies with IMRT and VMAT plans, the difference in MLC leaf width had a limited effect on planning target volumes (PTVs). Organs at risk (OARs) were more affected by a reduction in dose transmission through the MLC than by a reduction in MLC leaf width. The results of the test case studies and clinical case studies were mostly similar. In the latter, the different MLCs had no effect on the PTV regardless of the treatment method; however, the HD120MLC plans achieved dose reductions to OARs similar to or larger than the dose reduction of the M120MLC plans. The similar results of the test case and clinical case studies showed that despite a limitation of the irradiation field size, the HD120MLC plans were superior.
引用
收藏
页码:511 / 525
页数:14
相关论文
共 50 条
  • [1] Influence of multi-leaf collimator leaf transmission on head and neck intensity-modulated radiation therapy and volumetric-modulated arc therapy planning
    Sasaki, Motoharu
    Tominaga, Masahide
    Kamomae, Takeshi
    Ikushima, Hitoshi
    Kitaoka, Motonori
    Bando, Ryota
    Sakuragawa, Kanako
    Oita, Masataka
    JAPANESE JOURNAL OF RADIOLOGY, 2017, 35 (09) : 511 - 525
  • [2] Dosimetric Effect of Multi-Leaf Collimator Transmission On Intensity-Modulated Radiation Therapy
    Yang, R.
    Wang, J.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [3] Quantification of Treatment Plan Deliverability in Breast Volumetric-modulated Arc Therapy With Agility Multi-leaf Collimator
    Oh, Do Hoon
    Choi, Jin Hwa
    Ryu, Hyejo
    Chun, Minsoo
    IN VIVO, 2024, 38 (05): : 2254 - 2260
  • [4] Impact of MLC leaf width on volumetric-modulated arc therapy planning for head and neck cancers
    Lafond, Caroline
    Chajon, Enrique
    Devillers, Anne
    Louvel, Guillaume
    Toublanc, Sandra
    Olivier, Mickael
    Simon, Antoine
    de Crevoisier, Renaud
    Manens, Jean-Pierre
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (06): : 40 - 52
  • [5] Clinical significance of multi-leaf collimator positional errors for volumetric modulated arc therapy
    Oliver, Mike
    Gagne, Isabelle
    Bush, Karl
    Zavgorodni, Sergei
    Ansbacher, Will
    Beckham, Wayne
    RADIOTHERAPY AND ONCOLOGY, 2010, 97 (03) : 554 - 560
  • [6] Analysis of Multi-Leaf Collimator Leaf Position Errors in Volumetric Modulated Arc Therapy for Nasopharyngeal Carcinoma
    Li, C.
    Yin, Y.
    MEDICAL PHYSICS, 2016, 43 (06) : 3514 - 3514
  • [7] Plan Robustness Study of Volumetric-Modulated Arc Therapy Vs. Intensity-Modulated Radiation Therapy for Head and Neck Cancer
    Liu, W.
    Patel, S.
    Shen, J.
    Harrington, D.
    Stoker, J.
    Ding, X.
    Hu, Y.
    Wong, W.
    Halyard, M.
    Schild, S.
    Ezzell, G.
    Bues, M.
    MEDICAL PHYSICS, 2015, 42 (06) : 3478 - 3478
  • [8] IMPACT OF COLLIMATOR LEAF WIDTH FOR INTENSITY MODULATED RADIOTHERAPY AND VOLUMETRIC INTENSITY MODULATED ARC THERAPY
    Krayenbuehl, J.
    Linsenmeier, C.
    Kloeck, S.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2011, 187 (08) : 518 - 518
  • [9] Validation of Delivery Consistency for Intensity-Modulated Radiation Therapy and Volumetric-Modulated Arc Therapy Plans
    Woon, Wui Ann
    Ravindran, Paul B.
    Ekayanake, Piyasiri
    Lim, Yivonne Yih Fang
    JOURNAL OF MEDICAL PHYSICS, 2018, 43 (02) : 119 - 128
  • [10] Influence of multi-leaf collimator leaf width in radiosurgery via volumetric modulated arc therapy and 3D dynamic conformal arc therapy
    Serna, Alfredo
    Puchades, Vicente
    Mata, Fernando
    Ramos, David
    Alcaraz, Miguel
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (03): : 293 - 296