CT Reconstruction Algorithm and Low Contrast Detectability of Phantom Study: A Systematic Review and Meta-Analysis

被引:0
|
作者
Yusof, Nur Aimi Adibah [1 ]
Karim, Muhammad Khalis Abdul [1 ]
Asikin, Nursyazalina Mohd [1 ]
Paiman, Suriati [1 ]
Kechik, Mohd Mustafa Awang [1 ]
Rahman, Mohd Amiruddin Abdul [1 ]
Noor, Noramaliza Mohd [2 ]
机构
[1] Univ Putra Malaysia, Fac Sci, Dept Phys, Seri Kembangan 43400, Malaysia
[2] Univ Putra Malaysia, Fac Med, Dept Radiol, Seri Kembangan 43400, Malaysia
关键词
Computed tomography; phantom study; filtered back projection; low contrast detectability; iterative reconstruction; radiation; IMAGE QUALITY; ITERATIVE RECONSTRUCTION; COMPUTED-TOMOGRAPHY; SCAN PARAMETERS; PERFORMANCE; RESOLUTION;
D O I
10.2174/1573405618666220816160544
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background For almost three decades, computed tomography (CT) has been extensively used in medical diagnosis, which led researchers to conduct linking of CT dose exposure with image quality. Methods In this study, a systematic review and a meta-analysis study were conducted on CT phantom for resolution study especially based on the low contrast detectability (LCD). Furthermore, the association between the CT parameter such as tube voltage and the type of reconstruction algorithm, the amount of phantom scanning affecting the image quality and the exposure dose were also investigated in this study. We utilize PubMed, ScienceDirect, Google Scholar and Scopus databases to search related published articles from the year 2011 until 2020. The notable keywords comprise "computed tomography", "CT phantom", and "low contrast detectability". Of 52 articles, 20 articles are within the inclusion criteria in this systematic review. Results The dichotomous outcomes were chosen to represent the results in terms of risk ratio as per meta-analysis study. Notably, the noise in iterative reconstruction (IR) reduced by 24%, 33% and 36% with the use of smooth, medium and sharp filters, respectively. Furthermore, adaptive iterative dose reduction (AIDR 3D) improved image quality and the visibility of smaller less dense objects compared to filtered back-projection. Most of the researchers used 120 kVp tube voltage to scan phantom for quality assurance study. Conclusion Hence, optimizing primary factors such as tube potential reduces the dose exposure significantly, and the optimized IR technique could substantially reduce the radiation dose while maintaining the image quality.
引用
收藏
页码:1105 / 1113
页数:9
相关论文
共 50 条
  • [21] CT-angiography prior to diep flap breast reconstruction: A systematic review and meta-analysis
    Teunis, T.
    van Voss, M. R. Heerma
    Kon, M.
    van Maurik, J. F. M. Macare
    MICROSURGERY, 2013, 33 (06) : 496 - 502
  • [22] Deep-learning CT reconstruction in clinical scans of the abdomen: a systematic review and meta-analysis
    Shehata, Mostafa A.
    Saad, Abdelrahman M.
    Kamel, Serageldin
    Stanietzky, Nir
    Roman-Colon, Alicia M.
    Morani, Ajaykumar C.
    Elsayes, Khaled M.
    Jensen, Corey T.
    ABDOMINAL RADIOLOGY, 2023, 48 (08) : 2724 - 2756
  • [23] Implication of applying iterative reconstruction on Low Contrast Detectability in CT brain examination
    Kayun, Z.
    Karim, M. K. A.
    Muhammad, N. A.
    Aljewaw, O. B.
    Chew, M. T.
    Harun, H. H.
    RADIATION PHYSICS AND CHEMISTRY, 2021, 188
  • [24] Low-contrast detectability of a new multislice versus a monoslice helical CT in a liver phantom
    Kopka, L
    He, HD
    Foley, WD
    Hu, H
    Jacobson, DR
    Grabbe, EH
    RADIOLOGY, 1998, 209P : 284 - 284
  • [25] Low contrast detectability performance of model observers based on CT phantom images: kVp influence
    Hernandez-Giron, I.
    Calzado, A.
    Geleijns, J.
    Joemai, R. M. S.
    Veldkamp, W. J. H.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (07): : 798 - 807
  • [26] The effects of iterative reconstruction in CT on low-contrast liver lesion volumetry: a phantom study
    Li, Qin
    Berman, Benjamin P.
    Schumacher, Justin
    Liang, Yongguang
    Gavrielides, Marios A.
    Yang, Hao
    Zhao, Binsheng
    Petrick, Nicholas
    MEDICAL IMAGING 2017: COMPUTER-AIDED DIAGNOSIS, 2017, 10134
  • [27] Flap reconstruction for sacrectomy defects: A systematic review and meta-analysis
    Asaad, Malke
    Rajesh, Aashish
    Wahood, Waseem
    Vyas, Krishna S.
    Houdek, Matthew T.
    Rose, Peter S.
    Moran, Steven L.
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2020, 73 (02): : 255 - 268
  • [28] Materials Used in Cranial Reconstruction: A Systematic Review and Meta-Analysis
    Khalid, Syed, I
    Thomson, Kyle B.
    Maasarani, Samantha
    Wiegmann, Aaron L.
    Smith, Jenny
    Adogwa, Owoicho
    Mehta, Ankit, I
    Dorafshar, Amir H.
    WORLD NEUROSURGERY, 2022, 164 : E945 - E963
  • [29] Capsular contracture in breast reconstruction: A systematic review and meta-analysis
    Christodoulou, Neophytos
    Secanho, Murilo
    Kokosis, George
    Malgor, Rafael D.
    Winocour, Julian
    Yu, Jason W.
    Mathes, David W.
    Kaoutzanis, Christodoulos
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2024, 98 : 131 - 143
  • [30] ACL reconstruction in the pediatric population: A systematic review and meta-analysis
    Pacchiarini, Luca
    Pagliazzi, Gherardo
    Cuzzolin, Marco
    Delcogliano, Marco
    Deabate, Luca
    Filardo, Giuseppe
    Candrian, Christian
    SWISS MEDICAL WEEKLY, 2021, 151 : 27S - 27S