Fire resistance of external light gauge steel framed walls with brick veneer cladding

被引:4
|
作者
Pancheti, Jashnav [1 ]
Mahendran, Mahen [1 ]
机构
[1] Queensland Univ Technol QUT, Brisbane, Australia
基金
澳大利亚研究理事会;
关键词
External LSF walls; Brick veneer cladding; Fire resistance; Thermal properties; Experiments; MASONRY WALLS; BEHAVIOR;
D O I
10.1016/j.tws.2022.110162
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents the details of an experimental study to evaluate the fire resistance of external light-gauge steel-framed (LSF) walls with brick veneer cladding. Brick veneer is one of the most opted external cladding in Australian low to mid-rise construction for their aesthetic appeal with load bearing light-gauge steel framing or timber framing as the structural backing. However, no experimental data is available on the fire resistance of brick veneer walls with LSF backing. This experimental study included five small-scale non-load bearing fire tests of LSF walls with brick veneer cladding exposed to the standard fire. Two test walls with brick veneer constructed using normal and high temperature mortars were tested with fire from the external side (brick veneer exposed to fire), and the third wall constructed using normal mortar was tested with fire from the internal side (plasterboard exposed to fire). The first two test walls were also exposed to a second fire exposure. This study also included detailed elevated temperature thermal property tests of brick and the two types of mortar used in the fire tests. Brick veneer cladding provided very good protection to the thin-walled steel studs. No failure was observed in all the five fire tests giving fire resistance level of more than 240 min. Structural failure times of load bearing walls were also estimated to be more than 240 min for fire on the external side under load ratios of up to 0.4 while it was 30 min for fire on the internal side.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Light timber framed wall under fire: Effect of the load and cladding
    Piloto, Paulo A. G.
    Vergara, Diego
    ENGINEERING STRUCTURES, 2023, 280
  • [32] Thermal performance and thermal transmittance prediction of novel light-gauge steel-framed straw walls
    Sun, Kuo
    Zheng, Chaorong
    Wang, Xiaodong
    JOURNAL OF BUILDING ENGINEERING, 2023, 67
  • [33] Out-of-plane performance of a brick veneer steel-framed house subjected to seismic loads
    Paton-Cole, Vidal P.
    Gad, Emad F.
    Clifton, Charles
    Lam, Nelson T. K.
    Davies, Carl
    Hicks, Stephen
    CONSTRUCTION AND BUILDING MATERIALS, 2012, 28 (01) : 779 - 790
  • [34] Shear resistance of gypsum-sheathed light-gauge steel stud walls
    Serrette, R
    Ogunfunmi, K
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1996, 122 (04): : 383 - 389
  • [35] Numerical modeling of external light gauge steel framed wall systems exposed to bushfire flame zone conditions
    Hendawitharana, Sahani
    Ariyanayagam, Anthony
    Mahendran, Mahen
    FRONTIERS OF STRUCTURAL AND CIVIL ENGINEERING, 2024, 18 (09): : 1424 - 1444
  • [37] Height extrapolation of fire resistant non-loadbearing steel framed walls
    Collier, PCR
    FIRE AND MATERIALS, 2002, 26 (03) : 111 - 120
  • [38] Fire performance of non-load-bearing light-gauge slotted steel stud walls
    Liu, Faqi
    Fu, Feng
    Wang, Yuyin
    Liu, Qiang
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2017, 137 : 228 - 241
  • [39] Fire resistance of concrete walls with light aggregate
    Hertz, Kristian
    JOURNAL OF STRUCTURAL FIRE ENGINEERING, 2018, 9 (04) : 319 - 341
  • [40] Fire resistance of composite non-load bearing light steel framing walls
    Khetata, Seddik M.
    Piloto, Paulo A. G.
    Gavilan, Ana B. R.
    JOURNAL OF FIRE SCIENCES, 2020, 38 (02) : 136 - 155