Thermal performance and thermal transmittance prediction of novel light-gauge steel-framed straw walls

被引:8
|
作者
Sun, Kuo [1 ]
Zheng, Chaorong [1 ,2 ]
Wang, Xiaodong [3 ]
机构
[1] Harbin Inst Technol, Sch Civil Engn, Harbin 150090, Peoples R China
[2] Harbin Inst Technol, Minist Educ, Key Lab Struct Dynam Behav & Control, Harbin 150090, Peoples R China
[3] Harbin Univ Sci & Technol, Sch Architectural & Civil Engn, Harbin 150080, Peoples R China
来源
基金
国家重点研发计划;
关键词
Light -gauge steel -framed wall; Broken bridge; Straw boards; Thermal performance; U m -value prediction; BRIDGES;
D O I
10.1016/j.jobe.2023.105973
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Thermal bridges in light-gauge steel-framed exterior walls lead to more winter heat loss, summer heat gain, and building pathologies generated by moisture condensation and mould growth, which are unfavorable for building energy efficiency and service life of sheathing panels. A novel light-gauge steel-framed straw wall with a nonmetallic broken bridge layer was proposed, which consists of two sheathing panels on both sides of the wall, two frames, a middle sandwich layer, and two kinds of fasteners. The environmentally friendly straw boards including paper straw board (PSB) and wheat straw strand board (WSSB) were used as middle sandwich layer and exterior panel respectively. This study focuses on the thermal performance and the prediction method of thermal transmittance (Um-value) for such walls. Tests using the temperature control box-heat flux meter method were carried out for three representative walls with different configurations. Based on analyses of the temperature and heat flux density distributions, it is found that the broken bridge layer and the airspaces between the sheathing panel and the track or the bracing can effectively reduce the thermal bridge effect, with the relative effects less than 5%. Based on the test results of the Um-values, different wall configurations were matched with the feasible climate zones on the basis of energy efficiency design. After the validation by comparing with the test results in terms of temperature, heat flux density, and Um-value, the numerical study was carried out to broaden the feasible climate zones, and walls with improved configurations were proposed and analyzed. The results show that, by replacing the unventilated airspaces with the expanded polystyrene (EPS) boards, a maximum improvement in thermal performance reaches 74.89%. Thus, the feasible climate zones of the walls have been extended to the severe cold zone. Finally, a thermal transmittance prediction methodology based on the calculation method specified in European Standard EN ISO 6946-2017 in conjunction with the modified method considering thermal bridge effect was used to predict the Um-values of the improved walls. This study provides a new design strategy with nonmetallic broken bridge layer to reduce the unfavorable influence of thermal bridges in light-gauge steel-framed walls. Such a design strategy contributes to less energy consumption in addition to making full use of agricultural waste straw, which plays a positive role in the development of green buildings.
引用
收藏
页数:21
相关论文
共 50 条
  • [1] Long-term performance of light-gauge steel-framed envelope structures
    Nieminen, J
    Salonvaara, M
    LIGHT-WEIGHT STEEL AND ALUMINIUM STRUCTURES, 1999, : 703 - 712
  • [2] Thermal insulation and thermal bridge of steel-framed walls
    Technical Development Bureau
    不详
    Nippon Steel Tech Rep, 79 (35-40):
  • [3] Experimental Research on Thermal Behavior of Light Gauge Steel-framed Composite Walls with Slotted Studs
    Wu Sheng
    Progress in Industrial and Civil Engineering III, Pt 1, 2014, 638-640 : 71 - 83
  • [4] Experimental research on thermal behavior of light gauge steel-framed composite walls with slotted studs
    Wu, Sheng
    Zhang, Su-Mei
    Yang, Hua
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2010, 42 (04): : 550 - 555
  • [5] Hygrothermal performance of light steel-framed walls
    Nieminen, J.
    Salonvaara, M.
    VTT Tiedotteita - Valtion Teknillinen Tutkimuskeskus, 2000, (2070): : 3 - 26
  • [6] Thermal Performance of Slotted Light Steel-Framed Composite Wall
    Yang, Zhijian
    Sun, Lisuo
    Nan, Bo
    Wei, Shunli
    ENERGIES, 2023, 16 (05)
  • [7] Thermal and sound insulation of lightweight steel-framed facade walls
    Roque, Eduardo
    Santos, Paulo
    Pereira, Andreia Carvalho
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2019, 25 (02) : 156 - 176
  • [8] A new demountable light-gauge steel framed wall: Flexural behavior, thermal performance and life cycle assessment
    Liu, Cong
    Mao, Xiaoyong
    He, Lin
    Chen, Xin
    Yang, Yu
    Yuan, Jian
    JOURNAL OF BUILDING ENGINEERING, 2022, 47
  • [9] Influence of cladding attachment structural elements on the thermal performance of lightweight steel-framed walls
    Alhawari, Abdalhadi
    Gretka, Voytek
    Lee, Ivan
    Roppel, Patrick
    Mukhopadhyaya, Phalguni
    JOURNAL OF BUILDING ENGINEERING, 2024, 87
  • [10] Thermal performance of lightweight steel-framed construction systems
    Santos, P.
    Martins, C.
    Simoes da Silva, L.
    METALLURGICAL RESEARCH & TECHNOLOGY, 2014, 111 (06) : 329 - 338