Thermal performance and thermal transmittance prediction of novel light-gauge steel-framed straw walls

被引:8
|
作者
Sun, Kuo [1 ]
Zheng, Chaorong [1 ,2 ]
Wang, Xiaodong [3 ]
机构
[1] Harbin Inst Technol, Sch Civil Engn, Harbin 150090, Peoples R China
[2] Harbin Inst Technol, Minist Educ, Key Lab Struct Dynam Behav & Control, Harbin 150090, Peoples R China
[3] Harbin Univ Sci & Technol, Sch Architectural & Civil Engn, Harbin 150080, Peoples R China
来源
基金
国家重点研发计划;
关键词
Light -gauge steel -framed wall; Broken bridge; Straw boards; Thermal performance; U m -value prediction; BRIDGES;
D O I
10.1016/j.jobe.2023.105973
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Thermal bridges in light-gauge steel-framed exterior walls lead to more winter heat loss, summer heat gain, and building pathologies generated by moisture condensation and mould growth, which are unfavorable for building energy efficiency and service life of sheathing panels. A novel light-gauge steel-framed straw wall with a nonmetallic broken bridge layer was proposed, which consists of two sheathing panels on both sides of the wall, two frames, a middle sandwich layer, and two kinds of fasteners. The environmentally friendly straw boards including paper straw board (PSB) and wheat straw strand board (WSSB) were used as middle sandwich layer and exterior panel respectively. This study focuses on the thermal performance and the prediction method of thermal transmittance (Um-value) for such walls. Tests using the temperature control box-heat flux meter method were carried out for three representative walls with different configurations. Based on analyses of the temperature and heat flux density distributions, it is found that the broken bridge layer and the airspaces between the sheathing panel and the track or the bracing can effectively reduce the thermal bridge effect, with the relative effects less than 5%. Based on the test results of the Um-values, different wall configurations were matched with the feasible climate zones on the basis of energy efficiency design. After the validation by comparing with the test results in terms of temperature, heat flux density, and Um-value, the numerical study was carried out to broaden the feasible climate zones, and walls with improved configurations were proposed and analyzed. The results show that, by replacing the unventilated airspaces with the expanded polystyrene (EPS) boards, a maximum improvement in thermal performance reaches 74.89%. Thus, the feasible climate zones of the walls have been extended to the severe cold zone. Finally, a thermal transmittance prediction methodology based on the calculation method specified in European Standard EN ISO 6946-2017 in conjunction with the modified method considering thermal bridge effect was used to predict the Um-values of the improved walls. This study provides a new design strategy with nonmetallic broken bridge layer to reduce the unfavorable influence of thermal bridges in light-gauge steel-framed walls. Such a design strategy contributes to less energy consumption in addition to making full use of agricultural waste straw, which plays a positive role in the development of green buildings.
引用
收藏
页数:21
相关论文
共 50 条
  • [21] Analysis on moisture transfer for two light steel-framed composite walls
    Research Station on Civil Engineering for Postdoctoral Fellows, Harbin Institute of Technology, Harbin 150090, China
    不详
    不详
    Harbin Gongye Daxue Xuebao, 2006, 11 (1819-1822):
  • [22] STUDY ON FLEXURAL AND DEMOUNTABLE BEHAVIOR OF A MODULAR LIGHT-GAUGE STEEL FRAMED WALL
    Liu, Cong
    Chen, Xin
    Mao, Xiaoyong
    He, Lin
    Yuan, Jian
    JOURNAL OF CIVIL ENGINEERING AND MANAGEMENT, 2023, 29 (02) : 143 - 156
  • [23] Design of light-gauge steel shear walls sheathed with thin steel plates
    Fulop, L. A.
    Hakola, I.
    STEEL - A NEW AND TRADITIONAL MATERIAL FOR BUILDING, 2006, : 127 - +
  • [24] The Relevance of Surface Resistances on the Conductive Thermal Resistance of Lightweight Steel-Framed Walls: A Numerical Simulation Study
    Santos, Paulo
    Abrantes, David
    Lopes, Paulo
    Moga, Ligia
    APPLIED SCIENCES-BASEL, 2024, 14 (09):
  • [25] Experimental study on shear performance of CCA-sheathed light-gauge steel framing walls
    Li, Yuanqi
    Hong, Chi
    Qin, Yafei
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2015, 36 (09): : 151 - 157
  • [26] Study on heat transfer of light steel-framed composite walls in cold area
    School of Municipal and Environmental Engineering, Harbin Institute of Technology, Harbin 150090, China
    不详
    不详
    J. Harbin Inst. Technol., 2007, SUPPL. (63-66):
  • [27] Study on mass transfer of light steel-framed composite walls in cold area
    Wang, Zhao-Jun
    Cui, Yong-Qi
    Zhang, Su-Mei
    Journal of Harbin Institute of Technology (New Series), 2007, 14 (SUPPL.) : 67 - 71
  • [28] Fire performance of non-load-bearing light-gauge slotted steel stud walls
    Liu, Faqi
    Fu, Feng
    Wang, Yuyin
    Liu, Qiang
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2017, 137 : 228 - 241
  • [29] Fire resistance of walls and floors using light-gauge steel shapes
    Sakumoto, Y
    Hirakawa, T
    Masuda, H
    Nakamura, K
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2003, 129 (11): : 1522 - 1530
  • [30] Design method for light-gauge steel shear walls sheathed with flat steel plates
    Fülöp, L.A.
    Hakola, I.
    Advanced Steel Construction, 2007, 3 (03): : 628 - 651