Metal artifacts and artifact reduction of neurovascular coils in photon-counting detector CT versus energy-integrating detector CT - in vitro comparison of a standard brain imaging protocol

被引:10
|
作者
Schmitt, Niclas [1 ]
Wucherpfennig, Lena [2 ]
Rotkopf, Lukas T. [3 ]
Sawall, Stefan [4 ]
Kauczor, Hans-Ulrich [2 ]
Bendszus, Martin [1 ]
Moehlenbruch, Markus A. [1 ]
Schlemmer, Heinz-Peter [3 ]
Vollherbst, Dominik F. [1 ]
机构
[1] Heidelberg Univ Hosp, Dept Neuroradiol, Neuenheimer Feld 400, D-69120 Heidelberg, Germany
[2] Heidelberg Univ Hosp, Dept Diagnost & Intervent Radiol, Neuenheimer Feld 420, D-69120 Heidelberg, Germany
[3] German Canc Res Ctr, Div Radiol, Neuenheimer Feld 280, D-69120 Heidelberg, Germany
[4] German Canc Res Ctr, Div Xray Imaging & Computed Tomog, Neuenheimer Feld 280, D-69120 Heidelberg, Germany
关键词
Metal artifact reduction; Coils; Photon-counting CT; Aneurysm; Brain imaging; COMPUTED-TOMOGRAPHY;
D O I
10.1007/s00330-022-09073-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives Photon-counting detector computed tomography (PCD-CT) is a promising new technique for CT imaging. The aim of the present study was the in vitro comparison of coil-related artifacts in PCD-CT and conventional energy-integrating detector CT (EID-CT) using a comparable standard brain imaging protocol before and after metal artifact reduction (MAR). Methods A nidus-shaped rubber latex, resembling an aneurysm of the cerebral arteries, was filled with neurovascular platinum coils and inserted into a brain imaging phantom. Image acquisition and reconstruction were repeatedly performed for PCD-CT and EID-CT (n = 10, respectively) using a standard brain imaging protocol. Moreover, linear interpolation MAR was performed for PCD-CT and EID-CT images. The degree of artifacts was analyzed quantitatively (standard deviation in a donut-shaped region of interest) and qualitatively (5-point scale analysis). Results Quantitative and qualitative analysis demonstrated a lower degree of metal artifacts in the EID-CT images compared to the total-energy PCD-CT images (e.g., 82.99 +/- 7.89 Hounsfield units (HU) versus 90.35 +/- 6.28 HU; p < 0.001) with no qualitative difference between the high-energy bin PCD-CT images and the EID-CT images (4.18 +/- 0.37 and 3.70 +/- 0.64; p = 0.575). After MAR, artifacts were more profoundly reduced in the PCD-CT images compared to the EID-CT images in both analyses (e.g., 2.35 +/- 0.43 and 3.18 +/- 0.34; p < 0.001). Conclusion PCD-CT in combination with MAR have the potential to provide an improved option for reduction of coil-related artifacts in cerebral imaging in this in vitro study.
引用
收藏
页码:803 / 811
页数:9
相关论文
共 50 条
  • [31] Spectral metal artifact reduction after posterior spinal fixation in photon-counting detector CT datasets
    Popp, Daniel
    Sinzinger, Andrea X.
    Decker, Josua A.
    Braun, Franziska
    Bette, Stefanie
    Risch, Franka
    Haerting, Mark
    Garthe, Tarik
    Scheurig-Muenkler, Christian
    Kroencke, Thomas J.
    Schwarz, Florian
    EUROPEAN JOURNAL OF RADIOLOGY, 2023, 165
  • [32] Influence of virtual monoenergetic reconstructions on coronary CT angiography-based fractional flow reserve with photon-counting detector CT: intra-individual comparison with energy-integrating detector CT
    Giuseppe Tremamunno
    Daniel Pinos
    Emese Zsarnoczay
    U. Joseph Schoepf
    Milan Vecsey-Nagy
    Chiara Gnasso
    Nicola Fink
    Dmitrij Kravchenko
    Muhammad Taha Hagar
    Joseph Griffith
    Jim O’Doherty
    Andrea Laghi
    Tilman Emrich
    Akos Varga-Szemes
    Insights into Imaging, 16 (1)
  • [33] Image Quality and Radiation Dose of CTPA With Iodine Maps: A Prospective Randomized Study of High-Pitch Mode Photon-Counting Detector CT Versus Energy-Integrating Detector CT
    Pannenbecker, Pauline
    Heidenreich, Julius F.
    Grunz, Jan-Peter
    Huflage, Henner
    Gruschwitz, Philipp
    Patzer, Theresa S.
    Feldle, Philipp
    Bley, Thorsten A.
    Petritsch, Bernhard
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2024, 222 (02)
  • [34] Photon-Counting Detector Computed Tomography Versus Energy-Integrating Detector Computed Tomography for Coronary Artery Calcium Quantitation
    McCollough, Cynthia H.
    Winfree, Tim N.
    Melka, Elnata F.
    Rajendran, Kishore
    Carter, Rickey E.
    Leng, Shuai
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2024, 48 (02) : 212 - 216
  • [35] Comparison of a Photon-Counting-Detector CT with an Energy-Integrating-Detector CT for Temporal Bone Imaging: A Cadaveric Study
    Zhou, W.
    Lane, J. I.
    Carlson, M. L.
    Bruesewitz, M. R.
    Witte, R. J.
    Koeller, K. K.
    Eckel, L. J.
    Carter, R. E.
    McCollough, C. H.
    Leng, S.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2018, 39 (09) : 1733 - 1738
  • [36] Comparison of Bone Evaluation and Metal Artifact between Photon-Counting CT and Five Energy-Integrating-Detector CT under Standardized Conditions Using Cadaveric Forearms
    Fukuda, Takeshi
    Yonenaga, Takenori
    Akao, Ryo
    Hashimoto, Tohru
    Maeda, Kazuhiro
    Shoji, Tomokazu
    Shioda, Shoichi
    Ishizaka, Yu
    Ojiri, Hiroya
    DIAGNOSTICS, 2024, 14 (04)
  • [37] Low-dose high-resolution chest CT in adults with cystic fibrosis: intraindividual comparison between photon-counting and energy-integrating detector CT
    Frings, Marko
    Welsner, Matthias
    Mousa, Christin
    Zensen, Sebastian
    Salhoefer, Luca
    Meetschen, Mathias
    Beck, Nikolas
    Bos, Denise
    Westhoelter, Dirk
    Wienker, Johannes
    Taube, Christian
    Umutlu, Lale
    Schaarschmidt, Benedikt M.
    Forsting, Michael
    Haubold, Johannes
    Sutharsan, Sivagurunathan
    Opitz, Marcel
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2024, 8 (01)
  • [38] A comparative study of image quality and diagnostic confidence in diagnosis and follow-up of scaphoid fractures using photon-counting detector CT and energy-integrating detector CT
    Kammerling, Nina
    Tesselaar, Erik
    Booij, Ronald
    Fornander, Lotta
    Persson, Anders
    Farnebo, Simon
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 173
  • [39] Beam hardening of K-edge contrast agents: a phantom study comparing clinical energy-integrating detector and photon-counting detector CT systems
    Amir Pourmorteza
    Arnaud Richard Choux
    Thomas Wesley Holmes
    U. Joseph Schoepf
    Marly van Assen
    Carlo De Cecco
    Tilman Emrich
    Akos Varga-Szemes
    European Radiology Experimental, 9 (1)
  • [40] An Intra-Individual Comparison of Low-keV Photon-Counting CT versus Energy-Integrating-Detector CT Angiography of the Aorta
    Hennes, Jan-Lucca
    Huflage, Henner
    Grunz, Jan-Peter
    Hartung, Viktor
    Augustin, Anne Marie
    Patzer, Theresa Sophie
    Pannenbecker, Pauline
    Petritsch, Bernhard
    Bley, Thorsten Alexander
    Gruschwitz, Philipp
    DIAGNOSTICS, 2023, 13 (24)