An Intra-Individual Comparison of Low-keV Photon-Counting CT versus Energy-Integrating-Detector CT Angiography of the Aorta

被引:1
|
作者
Hennes, Jan-Lucca [1 ]
Huflage, Henner [1 ]
Grunz, Jan-Peter [1 ]
Hartung, Viktor [1 ]
Augustin, Anne Marie [1 ]
Patzer, Theresa Sophie [1 ]
Pannenbecker, Pauline [1 ]
Petritsch, Bernhard [1 ]
Bley, Thorsten Alexander [1 ]
Gruschwitz, Philipp [1 ]
机构
[1] Univ Hosp Wurzburg, Dept Diagnost & Intervent Radiol, D-97080 Wurzburg, Germany
关键词
CT angiography; aorta; photon-counting-detector CT; radiation dose reduction; spectral imaging; COMPUTED-TOMOGRAPHY; NOISE; PITCH; REDUCTION; DISEASE; PHANTOM; MDCT;
D O I
10.3390/diagnostics13243645
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This retrospective study aims to provide an intra-individual comparison of aortic CT angiographies (CTAs) using first-generation photon-counting-detector CT (PCD-CT) and third-generation energy-integrating-detector CT (EID-CT). High-pitch CTAs were performed with both scanners and equal contrast-agent protocols. EID-CT employed automatic tube voltage selection (90/100 kVp) with reference tube current of 434/350 mAs, whereas multi-energy PCD-CT scans were generated with fixed tube voltage (120 kVp), image quality level of 64, and reconstructed as 55 keV monoenergetic images. For image quality assessment, contrast-to-noise ratios (CNRs) were calculated, and subjective evaluation (overall quality, luminal contrast, vessel sharpness, blooming, and beam hardening) was performed independently by three radiologists. Fifty-seven patients (12 women, 45 men) were included with a median interval between examinations of 12.7 months (interquartile range 11.1 months). Using manufacturer-recommended scan protocols resulted in a substantially lower radiation dose in PCD-CT (size-specific dose estimate: 4.88 +/- 0.48 versus 6.28 +/- 0.50 mGy, p < 0.001), while CNR was approximately 50% higher (41.11 +/- 8.68 versus 27.05 +/- 6.73, p < 0.001). Overall image quality and luminal contrast were deemed superior in PCD-CT (p < 0.001). Notably, EID-CT allowed for comparable vessel sharpness (p = 0.439) and less pronounced blooming and beam hardening (p < 0.001). Inter-rater agreement was good to excellent (0.58-0.87). Concluding, aortic PCD-CTAs facilitate increased image quality with significantly lower radiation dose compared to EID-CTAs.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Intra-individual comparison of coronary CT angiography-based FFR between energy-integrating and photon-counting detector CT systems
    Zsarnoczay, Emese
    Pinos, Daniel
    Schoepf, U. Joseph
    Fink, Nicola
    O'Doherty, Jim
    Gnasso, Chiara
    Griffith, Joseph
    Vecsey-Nagy, Milan
    Suranyi, Pal
    Maurovich-Horvat, Pal
    Emrich, Tilman
    Varga-Szemes, Akos
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2024, 399
  • [2] Intra-individual comparison of coronary artery stenosis measurements between energy-integrating detector CT and photon-counting detector CT
    Wolf, Elias V.
    Gnasso, Chiara
    Schoepf, U. Joseph
    Halfmann, Moritz C.
    O'Doherty, Jim
    Zsarnoczay, Emese
    Varga-Szemes, Akos
    Emrich, Tilman
    Fink, Nicola
    [J]. IMAGING, 2023, 15 (02): : 61 - 68
  • [3] Intra-individual comparison of epicardial adipose tissue characteristics on coronary CT angiography between photon-counting detector and energy-integrating detector CT systems
    Kravchenko, Dmitrij
    Vecsey-Nagy, Milan
    Tremamunno, Giuseppe
    Schoepf, U. Joseph
    O'Doherty, Jim
    Luetkens, Julian A.
    Kuetting, Daniel
    Isaak, Alexander
    Hagar, Muhammad Taha
    Emrich, Tilman
    Varga-Szemes, Akos
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2024, 181
  • [4] Performance of Spectral Photon-Counting Coronary CT Angiography and Comparison with Energy-Integrating-Detector CT: Objective Assessment with Model Observer
    Rotzinger, David C.
    Racine, Damien
    Becce, Fabio
    Lahoud, Elias
    Erhard, Klaus
    Si-Mohamed, Salim A.
    Greffier, Joel
    Viry, Anais
    Boussel, Loic
    Meuli, Reto A.
    Yagil, Yoad
    Monnin, Pascal
    Douek, Philippe C.
    [J]. DIAGNOSTICS, 2021, 11 (12)
  • [5] Intra-individual comparison of image quality of the coronary arteries between photon-counting detector and energy-integrating detector CT systems
    Pinos, Daniel
    Griffith III, Joseph
    Emrich, Tilman
    Schoepf, U. Joseph
    O'Doherty, Jim
    Zsarnoczay, Emese
    Fink, Nicola
    Vecsey-Nagy, Milan
    Suranyi, Pal
    Tesche, Christian
    Aquino, Gilberto J.
    Varga-Szemes, Akos
    Brandt, Verena
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2023, 166
  • [6] In vitro and in vivo optimized reconstruction for low-keV virtual monoenergetic photon-counting detector CT angiography of lower legs
    Graafen, Dirk
    Bart, Willi
    Halfmann, Moritz C.
    Mueller, Lukas
    Hobohm, Lukas
    Yang, Yang
    Neufang, Achim
    Espinola-Klein, Christine
    Pitton, Michael B.
    Kloeckner, Roman
    Emrich, Tilman
    Varga-Szemes, Akos
    [J]. EUROPEAN RADIOLOGY EXPERIMENTAL, 2024, 8 (01)
  • [7] Comparison of a Photon-Counting-Detector CT with an Energy-Integrating-Detector CT for Temporal Bone Imaging: A Cadaveric Study
    Zhou, W.
    Lane, J. I.
    Carlson, M. L.
    Bruesewitz, M. R.
    Witte, R. J.
    Koeller, K. K.
    Eckel, L. J.
    Carter, R. E.
    McCollough, C. H.
    Leng, S.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2018, 39 (09) : 1733 - 1738
  • [8] Comparison of Low Dose Performance of Photon-Counting and Energy Integrating CT
    Rajagopal, Jayasai R.
    Farhadi, Faraz
    Solomon, Justin
    Sahbaee, Pooyan
    Saboury, Babak
    Pritchard, William F.
    Jones, Elizabeth C.
    Samei, Ehsan
    [J]. ACADEMIC RADIOLOGY, 2021, 28 (12) : 1754 - 1760
  • [9] Low-dose CT of the abdomen: Initial experience on a novel photon-counting detector CT and comparison with energy-integrating detector CT
    Decker, Josua A.
    Bette, Stefanie
    Lubina, Nora
    Rippel, Katharina
    Braun, Franziska
    Risch, Franka
    Wollny, Claudia
    Scheurig-Muenkler, Christian
    Kroencke, Thomas J.
    Schwarz, Florian
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2022, 148
  • [10] CT Angiography of the Aorta Using Photon-counting Detector CT with Reduced Contrast Media Volume
    Higashigaito, Kai
    Mergen, Victor
    Eberhard, Matthias
    Jungblut, Lisa
    Hebeisen, Monika
    Ratzer, Susan
    Zanini, Bettina
    Kobe, Adrian
    Martini, Katharina
    Euler, Andre
    Alkadhi, Hatem
    [J]. RADIOLOGY-CARDIOTHORACIC IMAGING, 2023, 5 (01):