A transient flow analysis method for high-rate mud pulse telemetry in rotary steerable system

被引:7
|
作者
Han, Hu [1 ]
Xue, Liang [1 ]
Sun, Lewang [1 ]
Sheng, Wenkan [1 ]
Fan, Honghai [1 ]
Wang, Zhiming [2 ]
机构
[1] China Univ Petr, Coll Petr Engn, Beijing 102249, Peoples R China
[2] China Oilfield Serv Ltd, Tianjin 300451, Peoples R China
来源
GEOENERGY SCIENCE AND ENGINEERING | 2024年 / 232卷
关键词
MPT; Transient flow; Water hammer; MOC; Pressure wave; Unsteady friction; DESIGN; PROPAGATION; HAMMER;
D O I
10.1016/j.geoen.2023.212392
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
With the development of ultra-deep offshore and onshore deep-water wells, there is a growing demand for high-speed data transmission. Mud pulse telemetry (MPT) is the most commercially mature wireless data transmission method. The time-domain parameter analysis of the down-hole mud pulse pressure signal is useful to study the optimization measures of the down-hole signal. Currently, the main approaches are experiment and computa-tional fluid dynamics (CFD) numerical simulations, but both methods are time-consuming and costly, which is not conducive to multi-parameter studies. transient flow modelis widely used to analyze water hammers in pipelines, but its application to mud pulse telemetry (MPT) systems has been less studied. In this paper, based on the classical transient flow equation, the method of characteristics (MOC) is used to solve the governing equa-tion, and the boundary conditions suitable for the MPT are proposed and verified with the experiment and CFD method. Based on the newly established transient flow mathematical model, the generation characteristics of the downhole pressure wave and the influence law of key parameters are studied. The results show that the essence of continuous wave is a three-wave coupling of pressure wave, density wave and flow wave. With the trans-mission of continuous wave, unsteady friction will be generated in the wave region of the wellbore, increasing the attenuation degree of the signal. The amplitude of continuous wave increases with the increase of density and displacement, independent of frequency and viscosity. However, as the frequency and viscosity increase, the continuous wave will decay faster. This paper provides the new transient flow method with fast computational time and a technical means for MPT studies under subsequent drilling conditions.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] EXTREMELY SENSITIVE OPTICAL-DETECTION SYSTEM FOR STOPPED-FLOW MEASUREMENTS OF REACTIONS WITH VERY HIGH-RATE CONSTANTS OR SMALL ABSORBENCY CHANGES
    GOEZ, M
    BERICHTE DER BUNSEN-GESELLSCHAFT-PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 1987, 91 (06): : 616 - 619
  • [42] ANALYSIS OF THROMBUS FORMATION PROCESS BY FLOW INDUCED HIGH SHEAR RATE USING OPTICAL OBSERVATION METHOD
    Tamagawa, Masaaki
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2013, VOL 3B, 2014,
  • [43] Non-dimensional analysis of the transient flow rate and the coolant temperature in a reactor coolant system under different pump failures
    Gao, Hong
    Gao, Feng
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2016, 53 (12) : 1988 - 1998
  • [44] High-rate removal of As(III) from aqueous system with sulfhydryl magnetic biological bamboo charcoal nanocomposites prepared by chemical co-precipitation method
    Luo, Yi-wei
    Wan, Si
    Xiao, Jiang-jun
    Wu, Dai-she
    TRANSACTIONS OF NONFERROUS METALS SOCIETY OF CHINA, 2022, 32 (08) : 2757 - 2769
  • [45] Transient Voltage Analysis for Receiving Power System With High PV Penetration Based on Rational Fraction Fitting Method
    Lai Q.
    Chen M.
    Li S.
    Kang Z.
    Gan D.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2019, 39 (11): : 3186 - 3193
  • [46] High Efficiency Control Method for the Hall Thruster System through Constant Flow Rate Control by Power Supply Control
    Osuga, Hiroyuki
    Kurokawa, Fujio
    Tamida, Taichiro
    Yamamoto, Naoji
    IEICE TRANSACTIONS ON COMMUNICATIONS, 2012, E95B (01) : 133 - 142
  • [47] Transient analysis method using high pass filter circuit in VSC interfaced multi-terminal DC system
    Javaid, Samreen
    Li, Dongyu
    Ukil, Abhisek
    ELECTRIC POWER SYSTEMS RESEARCH, 2023, 216
  • [48] Finite element analysis of visco-elastic flow under high shear rate using the GSMAC-method
    Fujieda, T
    Tanahashi, T
    INTERNATIONAL JOURNAL OF COMPUTATIONAL FLUID DYNAMICS, 2000, 13 (02) : 203 - 210
  • [49] Analysis of the dynamic behavior of structures using the high-rate GNSS-PPP method combined with a wavelet-neural model: Numerical simulation and experimental tests
    Kaloop, Mosbeh R.
    Yigit, Cemal O.
    Hu, Jong W.
    ADVANCES IN SPACE RESEARCH, 2018, 61 (06) : 1512 - 1524
  • [50] A Design Analysis of High Flow Rate Serial Connection Multi-Chamber Piezoelectric Micropump for Drug Delivery System
    Kurniawan, Erry Dwi
    Budiawan, Widhya
    Chandra, Mochtar
    2021 INTERNATIONAL CONFERENCE ON RADAR, ANTENNA, MICROWAVE, ELECTRONICS, AND TELECOMMUNICATIONS (ICRAMET), 2021, : 210 - 214