A transient flow analysis method for high-rate mud pulse telemetry in rotary steerable system

被引:7
|
作者
Han, Hu [1 ]
Xue, Liang [1 ]
Sun, Lewang [1 ]
Sheng, Wenkan [1 ]
Fan, Honghai [1 ]
Wang, Zhiming [2 ]
机构
[1] China Univ Petr, Coll Petr Engn, Beijing 102249, Peoples R China
[2] China Oilfield Serv Ltd, Tianjin 300451, Peoples R China
来源
GEOENERGY SCIENCE AND ENGINEERING | 2024年 / 232卷
关键词
MPT; Transient flow; Water hammer; MOC; Pressure wave; Unsteady friction; DESIGN; PROPAGATION; HAMMER;
D O I
10.1016/j.geoen.2023.212392
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
With the development of ultra-deep offshore and onshore deep-water wells, there is a growing demand for high-speed data transmission. Mud pulse telemetry (MPT) is the most commercially mature wireless data transmission method. The time-domain parameter analysis of the down-hole mud pulse pressure signal is useful to study the optimization measures of the down-hole signal. Currently, the main approaches are experiment and computa-tional fluid dynamics (CFD) numerical simulations, but both methods are time-consuming and costly, which is not conducive to multi-parameter studies. transient flow modelis widely used to analyze water hammers in pipelines, but its application to mud pulse telemetry (MPT) systems has been less studied. In this paper, based on the classical transient flow equation, the method of characteristics (MOC) is used to solve the governing equa-tion, and the boundary conditions suitable for the MPT are proposed and verified with the experiment and CFD method. Based on the newly established transient flow mathematical model, the generation characteristics of the downhole pressure wave and the influence law of key parameters are studied. The results show that the essence of continuous wave is a three-wave coupling of pressure wave, density wave and flow wave. With the trans-mission of continuous wave, unsteady friction will be generated in the wave region of the wellbore, increasing the attenuation degree of the signal. The amplitude of continuous wave increases with the increase of density and displacement, independent of frequency and viscosity. However, as the frequency and viscosity increase, the continuous wave will decay faster. This paper provides the new transient flow method with fast computational time and a technical means for MPT studies under subsequent drilling conditions.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] The downsizing of a TSA system for an air purification unit using a high flow rate method
    T. Hidano
    M. Nakamura
    A. Nakamura
    M. Kawai
    Adsorption, 2011, 17 : 759 - 763
  • [32] The downsizing of a TSA system for an air purification unit using a high flow rate method
    Hidano, T.
    Nakamura, M.
    Nakamura, A.
    Kawai, M.
    ADSORPTION-JOURNAL OF THE INTERNATIONAL ADSORPTION SOCIETY, 2011, 17 (04): : 759 - 763
  • [33] Quantitative characterization and analysis of granule transformations: Role of intermittent gas sparging in a super high-rate anaerobic system
    Tsui, To-Hung
    Ekama, George A.
    Chen, Guang-Hao
    WATER RESEARCH, 2018, 139 : 177 - 186
  • [34] APPLICATION OF THE VIRTUAL PULSE-GENERATOR METHOD TO REAL-TIME CORRECTION OF COUNTING LOSSES IN HIGH-RATE GAMMA-RAY SPECTROSCOPY
    PEPELNIK, R
    WESTPHAL, GP
    ANDERS, B
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 226 (2-3): : 411 - 417
  • [35] Performance Evaluation of Controlled Arrival Rate System through Matrix Geometric Method Using Transient Analysis
    Shah, Wajiha
    Shah, Syed Asif Ali
    Kumar, Wanod
    MEHRAN UNIVERSITY RESEARCH JOURNAL OF ENGINEERING AND TECHNOLOGY, 2013, 32 (03) : 503 - 508
  • [36] Analysis and Optimization of Material Flow inside the System of Rotary Coolers and Intake Pipeline via Discrete Element Method Modelling
    Hlosta, Jakub
    Zurovec, David
    Rozbroj, Jiri
    Ramirez-Gomez, Alvaro
    Necas, Jan
    Zegzulka, Jiri
    ENERGIES, 2018, 11 (07)
  • [37] Stroke Risk Analysis, a System With a High Detection Rate of Atrial Fibrillation in Stroke and Transient Ischemic Attack
    Gomis, Meritxell
    Davalos, Antoni
    Purroy, Francisco
    Cardona, Pere
    Rodriguez-Campello, Ana
    Marti-Fabregas, Joan
    Pagola, Jorge
    Pardo, Laura
    Munoz-Narbona, Lucia
    Benabdelhak, Ikram
    Lara-Rodriguez, Blanca
    Cuadrado-Godia, Elisa
    Martinez-Domeno, Alejandro
    Maria Juega, Jesus
    Serena, Joaquin
    Alvarez-Ballano, Jesus
    Paipa, Andres
    Roquer, Jaume
    Abilleira, Sonia
    Neeter, Rob
    van de Groep, Abraham
    Molina, Carlos
    STROKE, 2020, 51 (01) : 262 - 267
  • [38] Propagation mechanism of single event transient and soft error rate analysis method based on four-value pulse parameters model
    Li Y.
    Cai G.
    Li T.
    Yang H.
    Dianzi Yu Xinxi Xuebao/Journal of Electronics and Information Technology, 2016, 38 (08): : 2113 - 2121
  • [39] Energy Variation Rate-Based Transient Stability Analysis Method for VDCOL Control of HVDC Transmission System
    Cao, Zeyu
    Gao, Bingtuan
    Liu, Xiaolin
    Wang, Xingang
    Zhou, Zhuan
    Zhang, Feng
    2022 IEEE SUSTAINABLE POWER AND ENERGY CONFERENCE (ISPEC), 2022,
  • [40] Developing a novel biofiltration treatment system by coupling high-rate infiltration trench technology with a plug-flow porous-media bioreactor
    Karakurt-Fischer, Sema
    Sanz-Prat, Alicia
    Greskowiak, Janek
    Ergh, Martin
    Gerdes, Heiko
    Massmann, Gudrun
    Ederer, Juergen
    Regnery, Julia
    Huebner, Uwe
    Drewes, Joerg E.
    SCIENCE OF THE TOTAL ENVIRONMENT, 2020, 722