Automated contouring and statistical process control for plan quality in a breast clinical trial

被引:1
|
作者
Baroudi, Hana [1 ,2 ,5 ]
Nguyen, Callistus I. Huy Minh [2 ]
Maroongroge, Sean [3 ]
Smith, Benjamin D. [4 ]
Niedzielski, Joshua S. [2 ]
Shaitelman, Simona F. [4 ]
Melancon, Adam [2 ]
Shete, Sanjay [1 ]
Whitaker, Thomas J. [2 ]
Mitchell, Melissa P. [4 ]
Arzu, Isidora Yvonne [4 ]
Duryea, Jack [2 ]
Hernandez, Soleil [1 ,2 ]
El Basha, Daniel [1 ,2 ]
Mumme, Raymond [2 ]
Netherton, Tucker [2 ]
Hoffman, Karen [4 ]
Court, Laurence [1 ,2 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, UTHlth Houston Grad Sch Biomed Sci, Houston, TX USA
[2] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Div Radiat Oncol, Houston, TX USA
[3] Univ Texas MD Anderson Canc Ctr, Dept Radiat Oncol, Div Radiat Oncol, Houston, TX USA
[4] Univ Texas MD Anderson Canc Ctr, Dept Breast Radiat Oncol, Div Radiat Oncol, Houston, TX USA
[5] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, 1400 Pressler St,FCT8-6014, Houston, TX 77030 USA
基金
美国国家科学基金会;
关键词
Automated segmentation; Radiotherapy clinical trial; Breast cancer; Plan quality assurance; RADIOTHERAPY; TARGET; QA; SEGMENTATION;
D O I
10.1016/j.phro.2023.100486
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Automatic review of breast plan quality for clinical trials is time-consuming and has some unique challenges due to the lack of target contours for some planning techniques. We propose using an auto-contouring model and statistical process control to independently assess planning consistency in retrospective data from a breast radiotherapy clinical trial. Materials and methods: A deep learning auto-contouring model was created and tested quantitatively and qualitatively on 104 post-lumpectomy patients' computed tomography images (nnUNet; train/test: 80/20). The autocontouring model was then applied to 127 patients enrolled in a clinical trial. Statistical process control was used to assess the consistency of the mean dose to auto-contours between plans and treatment modalities by setting control limits within three standard deviations of the data's mean. Two physicians reviewed plans outside the limits for possible planning inconsistencies. Results: Mean Dice similarity coefficients comparing manual and auto-contours was above 0.7 for breast clinical target volume, supraclavicular and internal mammary nodes. Two radiation oncologists scored 95% of contours as clinically acceptable. The mean dose in the clinical trial plans was more variable for lymph node auto-contours than for breast, with a narrower distribution for volumetric modulated arc therapy than for 3D conformal treatment, requiring distinct control limits. Five plans (5%) were flagged and reviewed by physicians: one required editing, two had clinically acceptable variations in planning, and two had poor auto-contouring. Conclusions: An automated contouring model in a statistical process control framework was appropriate for assessing planning consistency in a breast radiotherapy clinical trial.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] An Automated Tool for Treatment Plan Quality Evaluation and Clinical Trial Quality Assurance
    Wang, J.
    Chen, W.
    Studenski, M.
    Cui, Y.
    Lee, A.
    Xiao, Y.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [2] Clinical implementation of plan quality control for automated prostate planning
    Kusters, M.
    Dankers, F. J.
    Van Kollenburg, P.
    Smeenk, R. J.
    Monshouwer, R.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S90 - S90
  • [3] Clinical Implementation and Evaluation of Automated Contouring for Breast Malignancies
    Bonner, A.
    Travis, R.
    Cardenas, C.
    Soike, M.
    Boggs, H.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2023, 117 (02): : E458 - E458
  • [4] Quality Control of Automated CBCT Dose Reconstruction Using Statistical Process Control
    McPhee, K. C.
    Patel, T.
    Liu, Z.
    Zhang, B.
    McNiven, A. L.
    Tadic, T.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E385 - E385
  • [5] Objective evaluation of plan quality in the PATHOS clinical trial using automated treatment planning
    Berenato, Salvatore
    Evans, Mererid
    Webster, Richard
    Palaniappan, Nachi
    Nixon, Lisette
    Higgins, Emma
    Patel, Rush
    Millin, Anthony E.
    Hurt, Christian
    Heiberg, Christie
    Canham, Joanna
    Jones, Terence M.
    Miles, Elizabeth
    Beasley, Matthew
    Wheeler, Philip A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2024, 192 : S29 - S33
  • [6] A semi-automated tool for treatment plan-quality evaluation and clinical trial quality assurance
    Wang, Jiazhou
    Chen, Wenzhou
    Studenski, Matthew
    Cui, Yunfeng
    Lee, Andrew J.
    Xiao, Ying
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (13): : N181 - N187
  • [7] Application of a quality control plan for automated chemistry using a single rule by analyte control process.
    Kincaid, H
    Burrow, S
    Becker, S
    Yoshimura, H
    [J]. CLINICAL CHEMISTRY, 2002, 48 (06) : A2 - A2
  • [8] Quality Control of Product: Statistical Process Control
    Putri, Solehatin Ika
    Septyandi, Chandra Budhi
    Rohandani, Dwi Phayana
    [J]. PROCEEDINGS OF THE 2016 GLOBAL CONFERENCE ON BUSINESS, MANAGEMENT AND ENTREPRENEURSHIP, 2016, 15 : 259 - 267
  • [9] A Breast Auto-Contouring Model for Contour Verification in a Breast Radiotherapy Clinical Trial
    Baroudi, H.
    Nguyen, C.
    Maroongroge, S.
    Smith, B.
    Hoffman, K.
    Niedzielski, J.
    Shaitelman, S.
    Melancon, A.
    Shete, S.
    Whitaker, T.
    Duryea, J.
    Hernandez, S.
    El Basha, M.
    Mumme, R.
    Netherton, T.
    Court, L.
    [J]. MEDICAL PHYSICS, 2022, 49 (06) : E453 - E454
  • [10] Quality Assurance of Contouring for NRG Oncology/RTOG 1308 Clinical Trial Based on Automated Segmentation with Deep Active Learning
    Men, K.
    Geng, H.
    Biswas, T.
    Liao, Z.
    Xiao, Y.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01): : S22 - S23