Budget impact analysis of the freestyle libre flash continuous glucose monitoring system® in patients with diabetes mellitus type 1 in Chile

被引:0
|
作者
Palacios, Alfredo [1 ,2 ,3 ]
Cairoli, Federico Rodriguez [1 ]
Balan, Dario [1 ]
Balmaceda, Carlos [2 ,4 ]
Augustovski, Federico [1 ]
Pichon-Riviere, Andres [1 ]
Bardach, Ariel [1 ]
机构
[1] Inst Clin Effectiveness & Hlth Policy IECS, Dept Hlth Technol Assessment & Hlth Econ, Buenos Aires, Argentina
[2] Univ York, Ctr Hlth Econ, York, England
[3] Univ Buenos Aires, Dept Econ, Buenos Aires, Argentina
[4] Pontificia Univ Catolica Chile, Ctr Invest Clin, Unidad Evaluac Tecnol Sanit, Santiago, Chile
关键词
Budget impact analysis; Chile; cost analysis; diabetes mellitus; flash glucose monitoring; self-monitoring of blood glucose; severe hypoglycemic events; GLYCEMIC CONTROL; HYPOGLYCEMIA; ADULTS; HOSPITALIZATION; THERAPY; CARE;
D O I
10.1080/14737167.2023.2171989
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
ObjectiveTo estimate the budget impact of covering the FreeStyle Libre Flash Continuous Glucose Monitoring System (FSL) for type 1 Diabetes Mellitus patients (T1DM), compared to self-monitoring of blood glucose (SMBG), from the perspective of public and private third-party payers in Chile.MethodsA budget impact model was developed to estimate the cost difference between SMBG and FSL over five years. Two FSL coverage schemes were assessed. Input parameters were retrieved from the literature review and complemented by expert opinion. Healthcare costs were estimated by a micro-costing approach and reported in USD.ResultsFor a public sector third-party payer, incorporating FSL implied a cost increase up to USD 0.013 per member per month (PMPM) for the fifth year under the broad coverage scheme and a net saving of 0.0001 PMPM (all years) under the restricted coverage scheme. From a private sector third-party payer, incorporating FSL implied savings up to USD 0.028 PMPM (fifth year) for the broad coverage scheme and up to USD 0.012 PMPM (fifth year) for the restricted scheme.ConclusionIncorporating the FSL for T1DM patients was associated with a marginal incremental cost for the public sector third-party payer and cost savings in Chile's private healthcare sector.
引用
收藏
页码:353 / 363
页数:11
相关论文
共 50 条
  • [31] REAL WORLD EVIDENCE FOR DIURNAL GLYCEMIC CHANGES EVALUATED BY FREESTYLE LIBRE PRO FLASH CONTINUOUS GLUCOSE MONITORING (CGM) SYSTEM IN PATIENTS WITH TYPE 2 DIABETES
    Patange, S.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 : A124 - A125
  • [32] Insulin degludec overdose in an adolescent with type 1 diabetes: proactive management including monitoring using the Freestyle Libre flash glucose monitoring system
    Thompson, Harmony
    Lunt, Helen
    Fleckney, Cate
    Soule, Steven
    ENDOCRINOLOGY DIABETES AND METABOLISM CASE REPORTS, 2018,
  • [33] Differences of FreeStyle Libre Flash Glucose Monitoring System and Finger Pricks on Clinical Characteristics and Glucose Monitoring Satisfactions in Type 1 Diabetes Using Insulin Pump
    Al Hayek, Ayman A.
    Robert, Asirvatham A.
    Al Dawish, Mohamed A.
    CLINICAL MEDICINE INSIGHTS-ENDOCRINOLOGY AND DIABETES, 2019, 12
  • [35] Accuracy of FreeStyle Libre flash glucose monitoring in patients with type 2 diabetes who migrated from highlands to plains
    Sun, Zeng-Mei
    Du, Yuan-Ze
    Wang, Su-Yuan
    Sun, Shu-Yao
    Ye, Yan
    Sun, Xue-Ping
    Li, Ming-Xia
    He, Hua
    Long, Wun-Chun
    Zhang, Cheng-Hui
    Yao, Xuan-Yu
    Fan, Wu-Yi
    Wang, Ling
    Wu, Yun-Hong
    WORLD JOURNAL OF DIABETES, 2024, 15 (06)
  • [36] Efficacy and safety of Freestyle Libre glucose monitoring system: A retrospective study of adults with Type 1 diabetes
    Jordan, E. V.
    DIABETIC MEDICINE, 2019, 36 : 145 - 146
  • [37] Practical guidance for using the FreeStyle Libre flash continuous glucose monitoring in primary care
    Unger, Jeff
    Kushner, Pamela
    Anderson, John E.
    POSTGRADUATE MEDICINE, 2020, 132 (04) : 305 - 313
  • [38] EVALUATION OF FREESTYLE LIBRE FLASH GLUCOSE MONITORING SYSTEM ON GLYCEMIC CONTROL, HEALTH-RELATED QUALITY OF LIFE, AND FEAR OF HYPOGLYCEMIA IN PATIENTS WITH TYPE 1 DIABETES
    Al Hayek, A.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2018, 20 : A147 - A147
  • [39] The FreeStyle Libre flash glucose monitoring system: how it has improved glycaemic control for people with type 1 diabetes in Eastern Cheshire, UK
    Yadegarfar, Ghasem
    Anderson, Simon G.
    Khawaja, Zohaib
    Cortes, Gabriela
    Leivesley, Kathryn
    Metters, Ann
    Horne, Linda
    Steele, Tom
    Heald, Adrian H.
    CARDIOVASCULAR ENDOCRINOLOGY & METABOLISM, 2020, 9 (04): : 171 - 176
  • [40] Breaking through diabetes management barriers: Assessing the accuracy of Freestyle Libre Pro flash continuous glucose monitoring in diabetes patients with myocardial infarction
    Shen, Long
    Xu, Li
    Zhang, Chen
    Gong, Wei-Wei
    Jing, Xiao-Ting
    Cao, Min-Jia
    Shi, Fang-Hong
    Pu, Jun
    DIGITAL HEALTH, 2024, 10