Friction Tuned Mass Dampers in Seismic-Excited High-Rise Buildings with SSI Effects: A Reliability Assessment

被引:7
|
作者
Etedali, Sadegh [1 ]
Akbari, Morteza [1 ]
Seifi, Mohammad [1 ]
机构
[1] Birjand Univ Technol, Dept Civil Engn, POB 97175-569, Birjand, Iran
关键词
Reliability analysis; high-rise buildings; friction tuned mass damper; near-field earthquakes; soil-structure interaction effect; SMALL FAILURE PROBABILITIES; BASE-ISOLATED STRUCTURES; GROUND MOTIONS; OPTIMUM DESIGN; CUCKOO SEARCH; OPTIMIZATION; FTMD;
D O I
10.1142/S1793431122500221
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
The probabilistic performance of the seismic-excited structures supplemented with passive control devices has recently received attention. Friction tuned mass damper (FTMD) devise as a novel passive control device is inspired by the idea of the combination of the friction mechanism with the traditional tuned mass damper (TMD) device. Although the application of the FTMD device has recently been considered for seismic control of structures, to the best of the authors' knowledge, a probabilistic reliability evaluation of the high-rise building equipped with FTMD under near-field earthquakes considering soil-structure interaction (SSI) effects has not yet been addressed in the literature. In the presence of uncertainties considered for the structural model, FTMD model, foundation and soil model, and stochastic near-fault ground motion model, the reliability analyses are carried out on a benchmark 40-story building equipped with FTMD considering SSI effects to estimate the failure probabilities of both structures with and without FTMD. Three soil types, three earthquake magnitudes, three fault distances, and three seismic performance levels which include 162 reliability analyses are considered for the extension of the study. Considering different near-fault earthquake model parameters, a total average reduction of 51.13%, 49.42%, and 17.50% is given for the maximum inter-story drift ratio response of the structure equipped with FTMD than the uncontrolled ones. It is found that ignoring the uncertainties may result in an inaccurate estimation of the seismic responses of the tall buildings especially those built on soft soil near faults. The results show that the FTMD passive device is not able to satisfy the requirements of the seismic codes at the performance level of immediate occupancy, especially in high earthquake magnitudes and structures built near the fault. However, for the seismic performance levels of life safety and collapse prevention, the FTMD reduces failure probabilities of the structures for most conditions of the earthquake magnitudes and fault distances. The efficiency of the FTMD in the reduction of failure probability is often declined by increasing the softness of soils, especially for severe earthquakes closer to the fault.
引用
收藏
页数:23
相关论文
共 50 条
  • [1] Seismic control of vertically and horizontally irregular steel high-rise buildings by tuned mass dampers including SSI
    Kontoni D.-P.N.
    Farghaly A.A.
    Asian Journal of Civil Engineering, 2024, 25 (2) : 1995 - 2014
  • [2] Seismic control of T-shape in plan steel high-rise buildings with SSI effect using tuned mass dampers
    Kontoni D.-P.N.
    Farghaly A.A.
    Asian Journal of Civil Engineering, 2024, 25 (2) : 1725 - 1739
  • [3] Energy regenerative tuned mass dampers in high-rise buildings
    Shen, Wenai
    Zhu, Songye
    Xu, You-Lin
    Zhu, Hong-Ping
    STRUCTURAL CONTROL & HEALTH MONITORING, 2018, 25 (02):
  • [4] MULTIPLE TUNED MASS DAMPERS FOR SEISMIC-EXCITED TALL BUILDING
    Kim, Young-Moon
    You, Ki-Pyo
    You, Jang-Youl
    Paek, Sun-Young
    Nam, Byung-Hee
    Kim, Doo-Kie
    PROCEEDINGS OF INTERNATIONAL STRUCTURAL ENGINEERING AND CONSTRUCTION: INTERACTION BETWEEN THEORY AND PRACTICE IN CIVIL ENGINEERING AND CONSTRUCTION, 2016, : 217 - 222
  • [5] Experimental verification of seismic vibration control of high-rise buildings with friction-type multiple tuned mass dampers
    Lin, Ging-Long
    Lin, Chi-Chang
    Yang, Tsung-Han
    Lung, Hao-Yu
    ENGINEERING STRUCTURES, 2024, 302
  • [6] Seismic response of high-rise buildings through metaheuristic-based optimization using tuned mass dampers and tuned mass dampers inerter
    Caicedo, Daniel
    Lara-Valencia, Luis
    Blandon, John
    Graciano, Carlos
    JOURNAL OF BUILDING ENGINEERING, 2021, 34 (34):
  • [7] Effect of Multiple Tuned Mass Dampers for Vibration Control in High-Rise Buildings
    Suresh, Lekshmi
    Mini, K. M.
    PRACTICE PERIODICAL ON STRUCTURAL DESIGN AND CONSTRUCTION, 2019, 24 (04)
  • [8] Assessment of a seismic tuned mass damper with friction fail-safe mechanism for the vibration control of high-rise buildings
    Sano, Takeshi
    Shirai, Kazutaka
    Yoshida, Osamu
    Nishikage, Taketomo
    STRUCTURAL CONTROL & HEALTH MONITORING, 2021, 28 (12):
  • [9] Seismic Response of High-Rise Buildings Equipped with Base Isolation and Non-Traditional Tuned Mass Dampers
    Naderpour, Hosein
    Naji, Naghmeh
    Burkacki, Daniel
    Jankowski, Robert
    APPLIED SCIENCES-BASEL, 2019, 9 (06):
  • [10] An experimental study of vibration control of wind-excited high-rise buildings using particle tuned mass dampers
    Lu, Zheng
    Wang, Dianchao
    Masri, Sami F.
    Lu, Xilin
    SMART STRUCTURES AND SYSTEMS, 2016, 18 (01) : 93 - 115