Assessment of Microhardness of Conventional and Bulk-Fill Resin Composites Using Different Light-Curing Intensity

被引:6
|
作者
Jakupovic, Selma [1 ]
Pervan, Nedim [2 ]
Mesic, Elmedin [2 ]
Gavranovic-Glamoc, Alma [3 ]
Bajsman, Anita [4 ]
Muratovic, Enis [2 ]
Kazazic, Lejla [3 ]
Kantardzic-Kovacevic, Alma [5 ]
机构
[1] Univ Sarajevo, Fac Dent Clin, Dept Restorat Dent & Endodont, Sarajevo 71000, Bosnia & Herceg
[2] Univ Sarajevo, Fac Mech Engn, Dept Mech Design, Sarajevo 71000, Bosnia & Herceg
[3] Univ Sarajevo, Fac Dent Clin, Dept Prosthodont, Sarajevo 71000, Bosnia & Herceg
[4] Univ Sarajevo, Fac Dent Clin, Dept Dent Morphol Dent Anthropol & Forens, Sarajevo 71000, Bosnia & Herceg
[5] Univ Sarajevo, Fac Dent Clin, Sarajevo 71000, Bosnia & Herceg
关键词
resin composites; bulk-fill composites; microhardness; high-intensity curing; filler content; MECHANICAL-PROPERTIES; POLYMERIZATION SHRINKAGE; PHOTO-ACTIVATION; CONVERSION; CURE; RESTORATIVES; BEHAVIOR; STRESS; SIZE;
D O I
10.3390/polym15102250
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
(1) Background: This study evaluates the effect of a conventional/low-voltage light-curing protocol (LV protocol) (10 s with 1340 mW/cm(2)) and high-voltage light-curing protocol (HV protocol) (3 s with 3440 mW/cm(2)) on the microhardness (MH) of dental resin-based composites (RBCs). Five resin composites were tested: conventional Evetric (EVT), Tetric Prime (TP), Tetric Evo Flow (TEF), bulk-fill Tetric Power Fill (PFL), and Tetric Power Flow (PFW). (2) Materials and Methods: Two tested composites (PFW and PFL) were designed for high-intensity light curing. The samples were made in the laboratory in specially designed cylindrical molds; diameter = 6 mm and height = 2 or 4 mm, depending on the type of composite. Initial MH was measured on the top and bottom surfaces of composite specimens 24 h after light curing using a digital microhardness tester (QNESS 60 M EVO, ATM Qness GmbH, Mammelzen, Germany). The correlation between the filler content (wt%, vol%) and the MH of the RBCs was tested. For the calculation of depth-dependent curing effectiveness, the bottom/top ratio for initial MH was used. (3) Conclusions: MH of RBCs is more dependent on material composition than on light-curing protocol. Filler wt% has a greater influence on MH values compared to filler vol%. The bottom/top ratio showed values over 80% for bulk composites, while for conventional sculptable composites, borderline or suboptimal values were measured for both curing protocols.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] INFLUENCE OF BULK THICKNESS, CURING TIME, AND CURING UNIT TYPE ON THE MICROHARDNESS OF DIFFERENT-VISCOSITY BULK-FILL COMPOSITES
    Saipullaev, M.
    Erdemir, U.
    Yildiz, E.
    MECHANICS OF COMPOSITE MATERIALS, 2018, 54 (05) : 675 - 684
  • [22] Influence of Bulk Thickness, Curing Time, and Curing Unit Type on the Microhardness of Different-Viscosity Bulk-Fill Composites
    M. Saipullaev
    U. Erdemir
    E. Yildiz
    Mechanics of Composite Materials, 2018, 54 : 675 - 684
  • [23] The Effect of Different Light-curing Units and Tip Distances on the Polymerization Efficiency of Bulk-fill Materials
    Al Nahedh, H. N. A.
    Al-Senan, D. F.
    Alayad, A. S.
    OPERATIVE DENTISTRY, 2022, 47 (04) : E197 - E210
  • [24] Delayed light-curing of dual-cure bulk-fill composites on internal adaptation and depth of cure
    Rissato, Lucas Dutra
    Fraga, May Anny Alves
    Goncalves, Michelly Pires
    Sinhoreti, Mario Alexandre Coelho
    Correr-Sobrinho, Lourenco
    Correr, Americo Bortolazzo
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2023, 35 (04) : 698 - 704
  • [25] Limited reciprocity in curing efficiency of bulk-fill resin-composites
    Sadeghyar, Abdullah
    Watts, David C.
    Schedle, Andreas
    DENTAL MATERIALS, 2020, 36 (08) : 997 - 1008
  • [26] Influence of the Different Light-Curing TIPS in the Microhardness of a Composite Resin
    Dobrovolski, Max
    Busato, Priscilla do Monte R.
    Mendonca, Marcio J.
    Bosquirolli, Virginia
    Santos, Rosana A.
    Camilotti, Veridiana
    POLIMEROS-CIENCIA E TECNOLOGIA, 2010, 20 : 327 - 330
  • [27] Influence of Tip Diameter and Light Spectrum of Curing Units on the Properties of Bulk-Fill Resin Composites
    Cardoso, Igor Oliveiros
    Machado, Alexandre Coelho
    de Oliveira Fernandes, Luisa
    Soares, Paulo Vinicius
    Raposo, Luis Henrique Araujo
    EUROPEAN JOURNAL OF DENTISTRY, 2022, 16 (02) : 360 - 366
  • [28] Influence of a budget single-peak light-curing unit on the microhardness and bond strength of bulk-fill resin composites to the gingival floor of proximal class II cavity preparations
    Maucoski, Cristiane
    Balzer, Andressa Hamilko
    Souza, Amanda Kudrek de
    Braga, Stella Sueli Lourenco
    Sullivan, Braden
    Price, Richard Bendt
    Arrais, Cesar Augusto Galvao
    INTERNATIONAL JOURNAL OF ADHESION AND ADHESIVES, 2022, 118
  • [29] Relationship between battery level and irradiance of light-curing units and their effects on the hardness of a bulk-fill composite resin
    Oku Prochnow, Fernanda Harumi
    Manozzo Kunz, Patricia Valeria
    Correr, Gisele Maria
    Kaizer, Marina da Rosa
    Gonzaga, Carla Castiglia
    RESTORATIVE DENTISTRY AND ENDODONTICS, 2022, 47 (04):
  • [30] Effects of aging and light-curing unit type on the volume and internal porosity of bulk-fill resin composite restoration
    Al-Zain, Afnan O.
    Alboloshi, Elaf A.
    Amir, Walaa A.
    Alghilan, Maryam A.
    Munchow, Eliseu A.
    SAUDI DENTAL JOURNAL, 2022, 34 (03) : 243 - 248