Assessment of Microhardness of Conventional and Bulk-Fill Resin Composites Using Different Light-Curing Intensity

被引:6
|
作者
Jakupovic, Selma [1 ]
Pervan, Nedim [2 ]
Mesic, Elmedin [2 ]
Gavranovic-Glamoc, Alma [3 ]
Bajsman, Anita [4 ]
Muratovic, Enis [2 ]
Kazazic, Lejla [3 ]
Kantardzic-Kovacevic, Alma [5 ]
机构
[1] Univ Sarajevo, Fac Dent Clin, Dept Restorat Dent & Endodont, Sarajevo 71000, Bosnia & Herceg
[2] Univ Sarajevo, Fac Mech Engn, Dept Mech Design, Sarajevo 71000, Bosnia & Herceg
[3] Univ Sarajevo, Fac Dent Clin, Dept Prosthodont, Sarajevo 71000, Bosnia & Herceg
[4] Univ Sarajevo, Fac Dent Clin, Dept Dent Morphol Dent Anthropol & Forens, Sarajevo 71000, Bosnia & Herceg
[5] Univ Sarajevo, Fac Dent Clin, Sarajevo 71000, Bosnia & Herceg
关键词
resin composites; bulk-fill composites; microhardness; high-intensity curing; filler content; MECHANICAL-PROPERTIES; POLYMERIZATION SHRINKAGE; PHOTO-ACTIVATION; CONVERSION; CURE; RESTORATIVES; BEHAVIOR; STRESS; SIZE;
D O I
10.3390/polym15102250
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
(1) Background: This study evaluates the effect of a conventional/low-voltage light-curing protocol (LV protocol) (10 s with 1340 mW/cm(2)) and high-voltage light-curing protocol (HV protocol) (3 s with 3440 mW/cm(2)) on the microhardness (MH) of dental resin-based composites (RBCs). Five resin composites were tested: conventional Evetric (EVT), Tetric Prime (TP), Tetric Evo Flow (TEF), bulk-fill Tetric Power Fill (PFL), and Tetric Power Flow (PFW). (2) Materials and Methods: Two tested composites (PFW and PFL) were designed for high-intensity light curing. The samples were made in the laboratory in specially designed cylindrical molds; diameter = 6 mm and height = 2 or 4 mm, depending on the type of composite. Initial MH was measured on the top and bottom surfaces of composite specimens 24 h after light curing using a digital microhardness tester (QNESS 60 M EVO, ATM Qness GmbH, Mammelzen, Germany). The correlation between the filler content (wt%, vol%) and the MH of the RBCs was tested. For the calculation of depth-dependent curing effectiveness, the bottom/top ratio for initial MH was used. (3) Conclusions: MH of RBCs is more dependent on material composition than on light-curing protocol. Filler wt% has a greater influence on MH values compared to filler vol%. The bottom/top ratio showed values over 80% for bulk composites, while for conventional sculptable composites, borderline or suboptimal values were measured for both curing protocols.
引用
收藏
页数:15
相关论文
共 50 条
  • [11] The effects of extended curing time and radiant energy on microhardness and temperature rise of conventional and bulk-fill resin composites
    Matej Par
    Igor Repusic
    Hrvoje Skenderovic
    Ognjen Milat
    Jelena Spajic
    Zrinka Tarle
    Clinical Oral Investigations, 2019, 23 : 3777 - 3788
  • [12] The effects of extended curing time and radiant energy on microhardness and temperature rise of conventional and bulk-fill resin composites
    Par, Matej
    Repusic, Igor
    Skenderovic, Hrvoje
    Milat, Ognjen
    Spajic, Jelena
    Tarle, Zrinka
    CLINICAL ORAL INVESTIGATIONS, 2019, 23 (10) : 3777 - 3788
  • [13] Rapid high-intensity light-curing of bulk-fill composites: A quantitative analysis of marginal integrity
    Par, Matej
    Spanovic, Nika
    Marovic, Danijela
    Attin, Thomas
    Tarle, Zrinka
    Tauboeck, Tobias T.
    JOURNAL OF DENTISTRY, 2021, 111
  • [14] Bulk-fill resin composites: Polymerization properties and extended light curing
    Zorzin, Jose
    Maier, Eva
    Harre, Sarah
    Fey, Tobias
    Belli, Renan
    Lohbauer, Ulrich
    Petschelt, Anselm
    Taschner, Michael
    DENTAL MATERIALS, 2015, 31 (03) : 293 - 301
  • [15] Effect of light-curing time on microhardness of a restorative bulk-fill resin composite to lute CAD-CAM resin composite endocrowns
    Daher, Rene
    Ardu, Stefano
    Kleverlaan, Cornelis J.
    Di Bella, Enrico
    Feilzer, Albert J.
    Krejci, Ivo
    AMERICAN JOURNAL OF DENTISTRY, 2020, 33 (06): : 331 - 336
  • [16] The Effect of Two Different Light-Curing Units and Curing Times on Bulk-Fill Restorative Materials
    Bayrak, Gokcen Deniz
    Yaman-Dosdogru, Elif
    Selvi-Kuvvetli, Senem
    POLYMERS, 2022, 14 (09)
  • [17] Effect of the Sample Preparation and Light-curing Unit on the Microhardness and Degree of Conversion of Bulk-fill Resin-based Composite Restorations
    Braga, S. S. L.
    Schettini, A. C. T.
    Carvalho, E. L. O.
    Shimokawa, C. A. K.
    Price, R. B.
    Soares, C. J.
    OPERATIVE DENTISTRY, 2022, 47 (02) : 163 - 172
  • [18] Surface Microhardness of Bulk-Fill Resin Composites Handled With Gloves
    Berto-Inga, Julissa
    Santander-Rengifo, Flor
    Ladera-Castaneda, Marysela
    Lopez-Gurreonero, Carlos
    Perez-Vargas, Antonieta Castro
    Cornejo-Pinto, Alberto
    Cervantes-Ganoza, Luis
    Cayo-Rojas, Cesar
    INTERNATIONAL DENTAL JOURNAL, 2023, 73 (04) : 489 - 495
  • [19] Polymerization efficiency of bulk-fill dental resin composites with different curing modes
    Dionysopoulos, Dimitrios
    Tolidis, Kosmas
    Gerasimou, Paris
    JOURNAL OF APPLIED POLYMER SCIENCE, 2016, 133 (18)
  • [20] Curing profile of bulk-fill resin-based composites
    Li, Xin
    Pongprueksa, Pong
    Van Meerbeek, Bart
    De Munck, Jan
    JOURNAL OF DENTISTRY, 2015, 43 (06) : 664 - 672