Assessment of Microhardness of Conventional and Bulk-Fill Resin Composites Using Different Light-Curing Intensity

被引:6
|
作者
Jakupovic, Selma [1 ]
Pervan, Nedim [2 ]
Mesic, Elmedin [2 ]
Gavranovic-Glamoc, Alma [3 ]
Bajsman, Anita [4 ]
Muratovic, Enis [2 ]
Kazazic, Lejla [3 ]
Kantardzic-Kovacevic, Alma [5 ]
机构
[1] Univ Sarajevo, Fac Dent Clin, Dept Restorat Dent & Endodont, Sarajevo 71000, Bosnia & Herceg
[2] Univ Sarajevo, Fac Mech Engn, Dept Mech Design, Sarajevo 71000, Bosnia & Herceg
[3] Univ Sarajevo, Fac Dent Clin, Dept Prosthodont, Sarajevo 71000, Bosnia & Herceg
[4] Univ Sarajevo, Fac Dent Clin, Dept Dent Morphol Dent Anthropol & Forens, Sarajevo 71000, Bosnia & Herceg
[5] Univ Sarajevo, Fac Dent Clin, Sarajevo 71000, Bosnia & Herceg
关键词
resin composites; bulk-fill composites; microhardness; high-intensity curing; filler content; MECHANICAL-PROPERTIES; POLYMERIZATION SHRINKAGE; PHOTO-ACTIVATION; CONVERSION; CURE; RESTORATIVES; BEHAVIOR; STRESS; SIZE;
D O I
10.3390/polym15102250
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
(1) Background: This study evaluates the effect of a conventional/low-voltage light-curing protocol (LV protocol) (10 s with 1340 mW/cm(2)) and high-voltage light-curing protocol (HV protocol) (3 s with 3440 mW/cm(2)) on the microhardness (MH) of dental resin-based composites (RBCs). Five resin composites were tested: conventional Evetric (EVT), Tetric Prime (TP), Tetric Evo Flow (TEF), bulk-fill Tetric Power Fill (PFL), and Tetric Power Flow (PFW). (2) Materials and Methods: Two tested composites (PFW and PFL) were designed for high-intensity light curing. The samples were made in the laboratory in specially designed cylindrical molds; diameter = 6 mm and height = 2 or 4 mm, depending on the type of composite. Initial MH was measured on the top and bottom surfaces of composite specimens 24 h after light curing using a digital microhardness tester (QNESS 60 M EVO, ATM Qness GmbH, Mammelzen, Germany). The correlation between the filler content (wt%, vol%) and the MH of the RBCs was tested. For the calculation of depth-dependent curing effectiveness, the bottom/top ratio for initial MH was used. (3) Conclusions: MH of RBCs is more dependent on material composition than on light-curing protocol. Filler wt% has a greater influence on MH values compared to filler vol%. The bottom/top ratio showed values over 80% for bulk composites, while for conventional sculptable composites, borderline or suboptimal values were measured for both curing protocols.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] The effect of rapid high-intensity light-curing on micromechanical properties of bulk-fill and conventional resin composites
    Par, Matej
    Marovic, Danijela
    Attin, Thomas
    Tarle, Zrinka
    Tauboeck, Tobias T.
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [2] The effect of rapid high-intensity light-curing on micromechanical properties of bulk-fill and conventional resin composites
    Matej Par
    Danijela Marovic
    Thomas Attin
    Zrinka Tarle
    Tobias T. Tauböck
    Scientific Reports, 10
  • [3] Effect of Shortened Light-Curing Modes on Bulk-Fill Resin Composites
    Sampaio, C. S.
    Pizarro, P. G.
    Atria, P. J.
    Hirata, R.
    Giannini, M.
    Mahn, E.
    OPERATIVE DENTISTRY, 2020, 45 (05) : 496 - 505
  • [4] Effect of light-curing protocols on the mechanical behavior of bulk-fill resin composites
    Besegato, Joao Felipe
    Jussiani, Eduardo Inocente
    Andrello, Avacir Casanova
    Fernandes, Ricardo Vignoto
    Salomao, Fabio Martins
    Santana Vicentin, Bruno Luiz
    Dezan-Garbelini, Cassia Cilene
    Hoeppner, Marcio Grama
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2019, 90 : 381 - 387
  • [5] Effect of Light Curing Distance on Microhardness Profiles of Bulk-Fill Resin Composites
    Hasanain, Fatin A.
    Nassar, Hani M.
    Ajaj, Reem A.
    POLYMERS, 2022, 14 (03)
  • [6] Color changes in bulk-fill resin composites as a result of visible light-curing
    Hotta, Masato
    Murase, Yuki
    Shimizu, Shojiro
    Kusakabe, Shusuke
    Takagaki, Tomohiro
    Nikaido, Toru
    DENTAL MATERIALS JOURNAL, 2022, 41 (01) : 11 - 16
  • [7] Effect of rapid high-intensity light-curing on polymerization shrinkage properties of conventional and bulk-fill composites
    Par, Matej
    Marovic, Danijela
    Attin, Thomas
    Tarle, Zrinka
    Taubock, Tobias T.
    JOURNAL OF DENTISTRY, 2020, 101
  • [8] Evaluation of the Depth of Cure by Microhardness of Bulk-Fill Composites with Monowave and Polywave LED Light-Curing Units
    Thomaidis, Socratis
    Kampouropoulos, Dimitris
    Antoniadou, Maria
    Kakaboura, Afrodite
    APPLIED SCIENCES-BASEL, 2024, 14 (24):
  • [9] Impact of light-curing distance on the effectiveness of cure of bulk-fill resin-based composites
    Diab, Rana Abdelbaset
    Yap, Adrian Ujin
    Gonzalez, Maria Angela Garcia
    Yahya, Noor Azlin
    SAUDI DENTAL JOURNAL, 2021, 33 (08) : 1184 - 1189
  • [10] Polymerization efficiency of different bulk-fill resin composites cured by monowave and polywave light-curing units: a comparative study
    Elsharawy, Rahma Mohamed
    Eawsya, Mohamed Elshirbeny
    Abd Allah, Asmaa Mohamed
    El Embaby, Abeer El Sayed
    QUINTESSENCE INTERNATIONAL, 2024, 55 (04): : 264 - 272