Intraoperative electron beam intercomparison of 6 sites using mailed thermoluminescence dosimetry: Absolute dose and energy

被引:0
|
作者
Dries, Wim [1 ]
Petoukhova, Anna [2 ,7 ]
Hertsens, Nicolas [3 ]
Stevens, Piet [4 ]
Jarbinet, Valerie [5 ]
Bimmel-Nagel, Cathryn Huibregtse [1 ]
Weterings, Jan [1 ]
van Wingerden, Ko [2 ]
Bauwens, Charlotte [3 ]
Vanreusel, Verdi [4 ]
Simon, Stephane [6 ]
机构
[1] Catharina Hosp, Eindhoven, Netherlands
[2] Haaglanden Med Ctr, Dept Med Phys, Leidschendam, Netherlands
[3] AZ Groeninge, Dept Radiotherapy, Kortrijk, Belgium
[4] GZA Hosp, Antwerp, Belgium
[5] CHU Tivoli, La Louviere, Belgium
[6] Jules Bordet Inst, Brussels, Belgium
[7] Haaglanden Med Ctr, Dept Med Phys, POB 432, NL-2501 CK The Hague, Netherlands
关键词
IORT; Electron IORT (IOERT); Intraoperative electron beam dosimetry; Intercomparison; Thermoluminescence dosimetry; Absolute dose and energy; TASK FORCE/ACROP RECOMMENDATIONS; ESTRO/ACROP IORT RECOMMENDATIONS; RADIATION-THERAPY; AUDITS; TLD;
D O I
10.1016/j.ejmp.2024.103302
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In 2018, the Netherlands Commission on Radiation Dosimetry subcommittee on IORT initiated a limited intercomparison of electron IORT (IOERT) in Belgium and The Netherlands. The participating institutions have enough variability in age, type of equipment, and in dose calibration protocols. Methods: In this study, three types of IOERT-dedicated mobile accelerators were represented: Mobetron 2000, LIAC HWL and LIAC. Mobetron produces electron beams with energies of 6, 9 and 12 MeV, while LIAC HWL and LIAC can deliver 6, 8, 10 and 12 MeV electron beams. For all energies, the reference beam (10 cm diameter, 0 incidence) and 5 cm diameter beams were measured, as these smaller beams are used more frequently in clinic. The mailed TLD service from the Radiation Dosimetry Services (RDS, Houston, USA) has been used. Following RDS' standard procedures, each beam was irradiated to 300 cGy at d(max )with TLDs around d(max) and around depth of 50 % dose (R50). Absolute dose at 100 % and beam energy, expressed as R50, could be verified in this way. Results: All absolute doses and energies under reference conditions were well within RDS-stated uncertainties: dose deviations were <5 % and deviations in R50 were <5 mm. For the small 5 cm beams, all results were also within acceptance levels except one absolute dose value. Deviations were not significantly dependent on manufacturer, energy, diameter and calibration protocol. Conclusions: All absolute dose values, except one of a non-reference beam, and all energy values were well within the measurement accuracy of RDS TLDs.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Dosimetry and Implementation of High-Dose Rate MLC-Based GRID Therapy Using a 6MV Flattened Filter Free (FFF) Photon Beam
    Dou, K.
    Lerma, F.
    Jacobs, M.
    Li, B.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [42] Very high-energy electron dose calculation using the Fermi-Eyges theory of multiple scattering and a simplified pencil beam model
    Ronga, Maria Grazia
    Deut, Umberto
    Bonfrate, Anthony
    De Marzi, Ludovic
    MEDICAL PHYSICS, 2023, 50 (12) : 8009 - 8022
  • [43] Fabrication of three dimensional structures for an UV curable nanoimprint lithography mold using variable dose control with critical-energy electron beam exposure
    Mohamed, K.
    Alkaisi, M. M.
    Blaikie, R. J.
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 2007, 25 (06): : 2357 - 2360
  • [44] In-Vivo Dosimetry for Ultra-High Dose Rate (UHDR) Electron Beam FLASH Radiotherapy Using an Organic (Plastic), an Organic-Inorganic Hybrid and an Inorganic Point Scintillator System
    Vanreusel, Verdi
    Vallet, Hugo
    Wijnen, Jordi
    Cote, Benjamin
    Leblans, Paul
    Sterckx, Paul
    Vandenbroucke, Dirk
    Verellen, Dirk
    Nascimento, Luana de Freitas
    PHOTONICS, 2024, 11 (09)
  • [45] Predicting energy response of radiographic film in a 6 MV x-ray beam using Monte Carlo calculated fluence spectra and absorbed dose
    Palm, Å
    Kirov, AS
    LoSasso, T
    MEDICAL PHYSICS, 2004, 31 (12) : 3168 - 3178
  • [46] Dose and energy dependence of mechanical properties of focused electron-beam-induced pillar deposits from Cu(C5HF6O2)2
    Friedli, V.
    Utke, I.
    Molhave, K.
    Michler, J.
    NANOTECHNOLOGY, 2009, 20 (38)
  • [47] GRAFT-POLYMERIZATION BY MUTUAL IRRADIATION TECHNIQUE USING LOW-ENERGY ELECTRON-BEAM .6. EFFECT OF SOLUBILITY PARAMETER OF SOLVENTS ON ELECTRON-BEAM INDUCED GRAFT-POLYMERIZATION ONTO POLYETHYLENE FILMS
    MORI, K
    KOSHIISHI, K
    MASUHARA, K
    KOBUNSHI RONBUNSHU, 1992, 49 (03) : 205 - 212
  • [48] Reflection high-energy electron diffraction pattern of GaN grown on 6H-SiC by metalorganic molecular beam epitaxy using AlGaN template
    Honda, T
    Kawanishi, H
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 2003, 21 (04): : 1822 - 1824
  • [49] GRAFT-POLYMERIZATION BY MUTUAL IRRADIATION TECHNIQUE USING LOW-ENERGY ELECTRON-BEAM .3. ELECTRON-BEAM INDUCED GRAFT-POLYMERIZATION OF METHYL-METHACRYLATE ONTO POLYETHYLENE FILMS AT HIGH-DOSE RATES
    MORI, K
    KOSHIISHI, K
    MASUHARA, K
    KOBUNSHI RONBUNSHU, 1991, 48 (01) : 1 - 9
  • [50] Validation of GEANT4 simulations for percentage depth dose calculations in heterogeneous media by using small photon beams from the 6-MV Cyberknife: Comparison with photon beam dosimetry with EBT2 film
    Lee, Chung Il
    Yoon, Sei-Chul
    Shin, Jae Won
    Hong, Seung-Woo
    Suh, Tae Suk
    Min, Kyung Joo
    Lee, Sang Deok
    Chung, Su Mi
    Jung, Jae-Yong
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2015, 66 (08) : 1308 - 1316