Serum/plasma potassium monitoring using potentiometric point-of-care microanalyzers with improved ion selective electrodes

被引:10
|
作者
Calvo-Lopez, Antonio [1 ]
Arasa-Puig, Eva [1 ]
Alonso-Chamarro, Julian [1 ]
Puyol, Mar [1 ]
机构
[1] Autonomous Univ Barcelona, Dept Chem, Grp Sensors & Biosensors, Edif Cn, Barcelona 08193, Spain
关键词
Miniaturization; Point-of-care; Lab on a chip; Ion selective electrodes; Biological samples; Potassium; WATER RECYCLING PROCESSES; ANALYTICAL MICROSYSTEM; HUMAN SERUM; BLOOD-GAS; LIFETIME; MEMBRANES; AMMONIUM; SENSORS; NITRATE; SODIUM;
D O I
10.1016/j.talanta.2022.124100
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Different causes can trigger imbalances on homeostatic mechanisms between intracellular and extracellular compartments resulting in abnormal blood potassium concentrations (hypo or hyperkalemia). This can lead to serious consequences, even a life-threatening situation. Early diagnosis, treatment and follow-up are essential to minimize critical impacts in patients. Bedside determination of blood potassium is not accessible in all health care centers or in all emergency departments and far less common in this kind of centers in emerging countries. We have therefore proposed a portable, economic and long-lifetime potentiometric point-of-care (POC) analyt-ical microsystem to deal with this question. It is a continuous flow microfluidic platform, made of cyclic olefin copolymer (COC), which combines microfluidics and a detection system based on the potentiometric technique containing a potassium selective electrode with a novel composition of polymeric membrane, which improves lifetime. Its size is smaller than a credit card and shows a linear range of Nernst calibration equation from 1 to 26 mM K+, a detection limit of 0.16 mM K+, a satisfactory repeatability and reproducibility, and an analysis fre-quency of 20 samples h-1, requiring only 25 mu L as sample volume. Moreover, lifetime is as long as 9 months by intensive use. All these features comply with medical requirements. Human serum samples were analyzed with the developed device and the obtained results were compared with those provided by two methods: ICP-OES and another using ion selective electrodes. No significant differences were observed, demonstrating the suitability of the developed POC microanalyzer for bedside health applications.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] MONITORING NUTRIENT FILM SOLUTIONS USING ION-SELECTIVE ELECTRODES
    BAILEY, BJ
    HAGGETT, BGD
    HUNTER, A
    ALBERY, WJ
    SVANBERG, LR
    JOURNAL OF AGRICULTURAL ENGINEERING RESEARCH, 1988, 40 (02): : 129 - 142
  • [32] REFERENCES STANDARDS FOR ELECTROMETRIC DETERMINATION, WITH ION-SELECTIVE ELECTRODES, OF POTASSIUM AND CALCIUM IN BLOOD SERUM
    COVINGTON, AK
    ROBINSON, RA
    ANALYTICA CHIMICA ACTA, 1975, 78 (01) : 219 - 223
  • [33] POTENTIOMETRIC DETERMINATION OF NITROGEN-CONTAINING PHARMACEUTICALS USING ION-SELECTIVE FILM ELECTRODES
    GRANZHAN, AV
    CHARYKOV, AK
    JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 47 (10-11) : 1396 - 1399
  • [34] Potentiometric determination of diazepam, bromazepam and clonazepam using solid contact ion-selective electrodes
    Salem, AA
    Barsoum, BN
    Izake, EL
    ANALYTICA CHIMICA ACTA, 2003, 498 (1-2) : 79 - 91
  • [35] Innovative Potentiometric Quantification of Flutamide Using Novel Ion-Selective Electrodes with Sulfonphthalein Dyes
    Siddaraju, Chikkalingaiah
    Rajendraprasad, Nagaraju
    BRAZILIAN JOURNAL OF ANALYTICAL CHEMISTRY, 2025, 12 (46): : 30 - 49
  • [36] COMPUTER ANALYSIS OF DATA FROM POTENTIOMETRIC TITRATIONS USING ION-SELECTIVE INDICATOR ELECTRODES
    ISBELL, AF
    PECSOK, RL
    DAVIES, RH
    PURNELL, JH
    ANALYTICAL CHEMISTRY, 1973, 45 (14) : 2363 - 2369
  • [37] CONTINUOUS INTRAVASCULAR MONITORING OF PLASMA POTASSIUM USING POTASSIUM-SELECTIVE ELECTRODE CATHETERS
    LINTON, RAF
    LIM, M
    BAND, DM
    CRITICAL CARE MEDICINE, 1982, 10 (05) : 337 - 340
  • [38] Inexpensive ion-selective electrodes for the simultaneous monitoring of potassium and nitrate concentrations in nutrient solutions
    Miras, Marina
    Soledad Garcia, Maria
    Martinez, Vicente
    Angel Ortuno, Joaquin
    ANALYTICAL METHODS, 2021, 13 (31) : 3511 - 3520
  • [39] REPLACEMENT ION CHROMATOGRAPHY WITH POTENTIOMETRIC DETECTION USING A POTASSIUM-SELECTIVE MEMBRANE-ELECTRODE
    TROJANOWICZ, M
    MEYERHOFF, ME
    ANALYTICA CHIMICA ACTA, 1989, 222 (01) : 95 - 107
  • [40] Potentiometric determination of coextraction constants of potassium salts in ion-selective electrodes utilizing a nitrobenzene liquid membrane phase
    Silvester, Debbie S.
    Grygolowicz-Pawlak, Ewa
    Bakker, Eric
    ANALYTICA CHIMICA ACTA, 2010, 683 (01) : 92 - 95