Serum/plasma potassium monitoring using potentiometric point-of-care microanalyzers with improved ion selective electrodes

被引:10
|
作者
Calvo-Lopez, Antonio [1 ]
Arasa-Puig, Eva [1 ]
Alonso-Chamarro, Julian [1 ]
Puyol, Mar [1 ]
机构
[1] Autonomous Univ Barcelona, Dept Chem, Grp Sensors & Biosensors, Edif Cn, Barcelona 08193, Spain
关键词
Miniaturization; Point-of-care; Lab on a chip; Ion selective electrodes; Biological samples; Potassium; WATER RECYCLING PROCESSES; ANALYTICAL MICROSYSTEM; HUMAN SERUM; BLOOD-GAS; LIFETIME; MEMBRANES; AMMONIUM; SENSORS; NITRATE; SODIUM;
D O I
10.1016/j.talanta.2022.124100
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Different causes can trigger imbalances on homeostatic mechanisms between intracellular and extracellular compartments resulting in abnormal blood potassium concentrations (hypo or hyperkalemia). This can lead to serious consequences, even a life-threatening situation. Early diagnosis, treatment and follow-up are essential to minimize critical impacts in patients. Bedside determination of blood potassium is not accessible in all health care centers or in all emergency departments and far less common in this kind of centers in emerging countries. We have therefore proposed a portable, economic and long-lifetime potentiometric point-of-care (POC) analyt-ical microsystem to deal with this question. It is a continuous flow microfluidic platform, made of cyclic olefin copolymer (COC), which combines microfluidics and a detection system based on the potentiometric technique containing a potassium selective electrode with a novel composition of polymeric membrane, which improves lifetime. Its size is smaller than a credit card and shows a linear range of Nernst calibration equation from 1 to 26 mM K+, a detection limit of 0.16 mM K+, a satisfactory repeatability and reproducibility, and an analysis fre-quency of 20 samples h-1, requiring only 25 mu L as sample volume. Moreover, lifetime is as long as 9 months by intensive use. All these features comply with medical requirements. Human serum samples were analyzed with the developed device and the obtained results were compared with those provided by two methods: ICP-OES and another using ion selective electrodes. No significant differences were observed, demonstrating the suitability of the developed POC microanalyzer for bedside health applications.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Point-of-care monitoring of intracellular glutathione and serum triglyceride levels using a versatile personal glucose meter
    Xu, Jinqiong
    Qiao, Xiujuan
    Zhang, Jingjing
    Cheng, Ni
    Sheng, Qinglin
    Zheng, Jianbin
    Cao, Wei
    Yue, Tianli
    Lu, Yi
    ANALYTICAL METHODS, 2019, 11 (14) : 1849 - 1856
  • [22] POTASSIUM ACTIVITY DETERMINATIONS USING LIQUID ORGANIC ION SELECTIVE ELECTRODES
    FRANT, MS
    ROSS, JW
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1969, (SEP): : AN25 - &
  • [23] Aggregation and Binding-Directed FRET Modulation of Conjugated Polymer Materials for Selective and Point-of-Care Monitoring of Serum Albumins
    Hussain, Sameer
    Chen, Xi
    Wang, Chaofeng
    Hao, Yi
    Tian, Xuemeng
    He, Yulian
    Li, Jing
    Shahid, M.
    Iyer, Parameswar Krishnan
    Gao, Ruixia
    ANALYTICAL CHEMISTRY, 2022, 94 (30) : 10685 - 10694
  • [24] Ready to Use Electrochemical Sensor Strip for Point-of-Care Monitoring of Serum Lithium
    Singh, Urvasini
    Kumbhat, Sunita
    ELECTROANALYSIS, 2021, 33 (02) : 393 - 399
  • [25] MEASUREMENT OF SERUM SODIUM AND POTASSIUM BY ION-SELECTIVE ELECTRODES - A COMPARATIVE-ANALYSIS
    GROSS, SE
    KHAYAMBASHI, H
    CLINICAL CHEMISTRY, 1982, 28 (07) : 1629 - 1630
  • [26] PRECIPITATION POTENTIOMETRIC TITRATION OF PHYSIOLOGICALLY ACTIVE AMINES USING ION-SELECTIVE ELECTRODES
    EGOROV, VV
    REPIN, VA
    JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 48 (12) : 1387 - 1392
  • [27] Ion-Selective Electrodes for the Potentiometric Determination of Pramoxine HCl Using Different Ionophores
    Ramadan, Nesrin K.
    Merey, Hanan A.
    ACTA CHIMICA SLOVENICA, 2012, 59 (04) : 870 - 878
  • [29] Multianalyte detection using potentiometric ionophore-based ion-selective electrodes
    Cuartero, M.
    Ruiz, A.
    Oliva, D. J.
    Ortuno, J. A.
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 243 : 144 - 151
  • [30] DETERMINATION OF POTASSIUM CHLORINE RATIOS IN SEAWATER USING ION-SELECTIVE ELECTRODES
    ERMOLENKO, YE
    KHOROSHEV, VG
    VLASOV, YG
    JOURNAL OF APPLIED CHEMISTRY OF THE USSR, 1988, 61 (05): : 1044 - 1047