Anterior variable-angle locked plating versus tension band wiring of simple and complex patella fractures - a biomechanical investigation

被引:10
|
作者
Stoffel, Karl [1 ]
Zderic, Ivan [2 ]
Pastor, Torsten [2 ,3 ]
Woodburn, William [4 ]
Castle, Richard [4 ]
Penman, Jessica [4 ]
Saura-Sanchez, Eladio [5 ]
Gueorguiev, Boyko [2 ]
Sommer, Christoph [6 ]
机构
[1] Univ Hosp Basel, Petersgraben 4, CH-4031 Basel, Switzerland
[2] AO Res Inst Davos, Clavadelerstr 8, CH-7270 Davos, Switzerland
[3] Cantonal Hosp Lucerne, Spitalstr 16, CH-6000 Luzern, Switzerland
[4] DePuy Synth, 1310 Goshen Pkwy, W Chester, PA 19380 USA
[5] Univ Hosp Elche, Carrer Almazara 11, Elche 03203, Alicante, Spain
[6] Cantonal Hosp Graubunden, Loestr 170, CH-7000 Chur, Switzerland
关键词
Simple patella fracture; Complex patella fracture; Anterior variable-angle locked plating; Tension band wiring; Biomechanics; FIXATION; MESH; OSTEOSYNTHESIS; EPIDEMIOLOGY; OUTCOMES;
D O I
10.1186/s12891-023-06394-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BackgroundThe aim of this study was to investigate the biomechanical performance of novel anterior variable-angle locking plates versus tension band wiring used for fixation of simple and complex patella fractures.MethodsSixteen pairs of human cadaveric knees were used to simulate two-part simple transverse AO/OTA 34-C1 and five-part complex AO/OTA 34-C3 patella fractures. The complex fracture pattern was characterized with a medial and a lateral proximal fragment, together with an inferomedial, an inferolateral and an inferior fragment mimicking comminution around the distal patella pole. Eight pairs with simple fractures were split for fixation via either tension band wiring (TBW) through two parallel cannulated screws or anterior variable-angle locked plating, whereas other eight pairs with complex fractures were split for either TBW through two parallel cannulated screws plus circumferential cerclage wiring, or anterior variable-angle locked plating using a cortical caudo-cranial polar screw. Each specimen was tested over 5000 cycles with a range of motion from 90 degrees flexion to full extension by pulling on the quadriceps tendon. Interfragmentary movements were captured by motion tracking.ResultsFor both fracture types, the longitudinal and shear articular displacements, measured between the proximal and distal fragments at the central patella aspect between 1000 and 5000 cycles, together with the relative rotations of these fragments around the mediolateral axis were all significantly smaller following anterior variable-angle locked plating versus TBW, p <= 0.01.ConclusionsFrom a biomechanical perspective, anterior locked plating of both simple and complex patella fractures resulted in less interfragmentary displacement under extended cyclic loading.
引用
收藏
页数:10
相关论文
共 35 条
  • [31] Societal costs in displaced transverse olecranon fractures: using decision analysis tools to find the most cost-effective strategy between tension band wiring and locked plating
    Francis, Tittu
    Washington, Travis
    Srivastava, Karan
    Moutzouros, Vasilios
    Makhni, Eric C.
    Hakeos, William
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2017, 26 (11) : 1995 - 2003
  • [32] Cyclic long-term loading of a bilateral fixed-angle plate in comparison with tension band wiring with K-wires or cannulated screws in transverse patella fractures
    Simon Thelen
    Johannes Schneppendahl
    Ralf Baumgärtner
    Christian Eichler
    Jürgen Koebke
    Marcel Betsch
    Mohssen Hakimi
    Joachim Windolf
    Michael Wild
    Knee Surgery, Sports Traumatology, Arthroscopy, 2013, 21 : 311 - 317
  • [33] Cyclic long-term loading of a bilateral fixed-angle plate in comparison with tension band wiring with K-wires or cannulated screws in transverse patella fractures
    Thelen, Simon
    Schneppendahl, Johannes
    Baumgaertner, Ralf
    Eichler, Christian
    Koebke, Juergen
    Betsch, Marcel
    Hakimi, Mohssen
    Windolf, Joachim
    Wild, Michael
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2013, 21 (02) : 311 - 317
  • [34] Volar versus dorsal latest-generation variable-angle locking plates for the fixation of AO type 23C 2.1 distal radius fractures: A biomechanical study in cadavers
    Rausch, Sascha
    Schlonski, Olaf
    Klos, Kajetan
    Gras, Florian
    Gueorguiev, Boyko
    Hofmann, Gunther O.
    Mueckley, Thomas
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2013, 44 (04): : 523 - 526
  • [35] Tension band wiring versus locking plate fixation for simple, two-part Mayo 2A olecranon fractures: a comparison of post-operative outcomes, complications, reoperations and economics
    Powell A.J.
    Farhan-Alanie O.M.
    McGraw I.W.W.
    MUSCULOSKELETAL SURGERY, 2019, 103 (2) : 155 - 160