Anterior variable-angle locked plating versus tension band wiring of simple and complex patella fractures - a biomechanical investigation

被引:10
|
作者
Stoffel, Karl [1 ]
Zderic, Ivan [2 ]
Pastor, Torsten [2 ,3 ]
Woodburn, William [4 ]
Castle, Richard [4 ]
Penman, Jessica [4 ]
Saura-Sanchez, Eladio [5 ]
Gueorguiev, Boyko [2 ]
Sommer, Christoph [6 ]
机构
[1] Univ Hosp Basel, Petersgraben 4, CH-4031 Basel, Switzerland
[2] AO Res Inst Davos, Clavadelerstr 8, CH-7270 Davos, Switzerland
[3] Cantonal Hosp Lucerne, Spitalstr 16, CH-6000 Luzern, Switzerland
[4] DePuy Synth, 1310 Goshen Pkwy, W Chester, PA 19380 USA
[5] Univ Hosp Elche, Carrer Almazara 11, Elche 03203, Alicante, Spain
[6] Cantonal Hosp Graubunden, Loestr 170, CH-7000 Chur, Switzerland
关键词
Simple patella fracture; Complex patella fracture; Anterior variable-angle locked plating; Tension band wiring; Biomechanics; FIXATION; MESH; OSTEOSYNTHESIS; EPIDEMIOLOGY; OUTCOMES;
D O I
10.1186/s12891-023-06394-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BackgroundThe aim of this study was to investigate the biomechanical performance of novel anterior variable-angle locking plates versus tension band wiring used for fixation of simple and complex patella fractures.MethodsSixteen pairs of human cadaveric knees were used to simulate two-part simple transverse AO/OTA 34-C1 and five-part complex AO/OTA 34-C3 patella fractures. The complex fracture pattern was characterized with a medial and a lateral proximal fragment, together with an inferomedial, an inferolateral and an inferior fragment mimicking comminution around the distal patella pole. Eight pairs with simple fractures were split for fixation via either tension band wiring (TBW) through two parallel cannulated screws or anterior variable-angle locked plating, whereas other eight pairs with complex fractures were split for either TBW through two parallel cannulated screws plus circumferential cerclage wiring, or anterior variable-angle locked plating using a cortical caudo-cranial polar screw. Each specimen was tested over 5000 cycles with a range of motion from 90 degrees flexion to full extension by pulling on the quadriceps tendon. Interfragmentary movements were captured by motion tracking.ResultsFor both fracture types, the longitudinal and shear articular displacements, measured between the proximal and distal fragments at the central patella aspect between 1000 and 5000 cycles, together with the relative rotations of these fragments around the mediolateral axis were all significantly smaller following anterior variable-angle locked plating versus TBW, p <= 0.01.ConclusionsFrom a biomechanical perspective, anterior locked plating of both simple and complex patella fractures resulted in less interfragmentary displacement under extended cyclic loading.
引用
收藏
页数:10
相关论文
共 35 条
  • [21] Transverse patella fracture fixation: A cadaveric biomechanical comparison of cannulated screws and anterior tension band versus low-profile, multiplanar mesh plating
    Garner, Matthew R.
    Homcha, Brittany
    Cowman, Trevin
    Goss, Madison
    Reid, J. Spence
    Lewis, Gregory S.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2024, 55 (06):
  • [22] Comparison of Cannulated Screw With Tension Band Wiring Versus Compressive Cannulated Locking Bolt and Nut Device (CompresSURE) in Patella Fractures-A Cadaveric Biomechanical Study
    Domby, Brian
    Henderson, Eric
    Nayak, Aniruddh
    Erdogan, Murat
    Gutierrez, Sergio
    Santoni, Brandon G.
    Sagi, H. Claude
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2012, 26 (12) : 678 - 683
  • [23] SURGICAL OUTCOMES OF FIFTH METACARPAL NECK FRACTURES - A COMPARATIVE ANALYSIS OF DORSAL PLATING VERSUS TENSION BAND WIRING
    Wong, Khai Phang
    Hay, Robyn Aik Siew
    Tay, Shian Chao
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2015, 20 (01): : 99 - 105
  • [24] Open Reduction and Internal Fixation of Displaced Patella Inferior Pole Fractures With Anterior Tension Band Wiring Through Cannulated Screws
    Chang, Shi-Min
    Ji, Xiang-Ling
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2011, 25 (06) : 366 - 370
  • [25] Cost Assessment of Plating Versus Tension Band Wiring Constructs for Treating Mayo Type 2A Olecranon Fractures
    Steadman, Jesse N.
    Stephens, Andrew R.
    Zhang, Chong
    Presson, Angela P.
    Kazmers, Nikolas H.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2022, 47 (04): : 311 - 319
  • [26] A Randomized Comparative Study of Functional and Radiological Outcome of Tension Band Wiring for Patella Fractures Using SS Wire Versus Fiberwire
    Noothan, P. T.
    Somashekara, S. A.
    Sunkappa, S. R.
    Karthik, B.
    Rameshkrishnan, K.
    INDIAN JOURNAL OF ORTHOPAEDICS, 2023, 57 (06) : 876 - 883
  • [27] A Randomized Comparative Study of Functional and Radiological Outcome of Tension Band Wiring for Patella Fractures Using SS Wire Versus Fiberwire
    P. T. Noothan
    S. A. Somashekara
    S. R. Sunkappa
    B. Karthik
    K. Rameshkrishnan
    Indian Journal of Orthopaedics, 2023, 57 : 876 - 883
  • [28] Comparative study of locking neutralization plate construct versus tension band wiring with a cannulated screw for patella fractures: experimental and finite element analysis
    Sunjung Kim
    Nirav Mungalpara
    Rohan Wangikar
    Majd Tarabichi
    Joseph Karam
    Asheesh Bedi
    Jason Koh
    Farid Amirouche
    Journal of Orthopaedic Surgery and Research, 19
  • [29] Comparative study of locking neutralization plate construct versus tension band wiring with a cannulated screw for patella fractures: experimental and finite element analysis
    Kim, Sunjung
    Mungalpara, Nirav
    Wangikar, Rohan
    Tarabichi, Majd
    Karam, Joseph
    Bedi, Asheesh
    Koh, Jason
    Amirouche, Farid
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2024, 19 (01)
  • [30] Functional outcomes of tension band wiring versus hook plating in displaced, closed, and isolated distal clavicle fractures in adults: a comparative retrospective study
    Eskandar, Mohammad
    Saed, Maen
    Yusuf, Safwan
    ANNALS OF MEDICINE AND SURGERY, 2024, 86 (11): : 6409 - 6415