Interior-point-method-based switching angle computation for selective harmonic elimination in high-frequency cascaded H-bridge multilevel inverters

被引:0
|
作者
Long, Gen [1 ]
Wu, Xiang-Long [1 ]
Liu, Heng-Yang [1 ]
Lou, Hang-Chuan [1 ]
Shen, Bo-Han [2 ]
Yan, Chen [1 ]
Kong, Wu-Bin [1 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Elect & Elect, Wuhan, Peoples R China
[2] Wuhan Inst Technol, Sch Mech & Elect Engn, Wuhan, Peoples R China
关键词
Interior point method; Switching angle computation; High-frequency cascaded H-bridge multilevel inverter; Selective harmonic elimination; SHE-PWM; OPTIMIZATION; CONVERTERS;
D O I
10.1007/s43236-024-00793-6
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
To transmit high power very-low-frequency signals with low harmonic content, the high-frequency cascaded H-bridge multilevel inverter (HF-MLI) usually has large number of levels and uses the selective harmonic elimination (SHE) technique for modulation. However, when the number of levels exceeds 25, the conventional SHE switching angle computation methods have a problem since the computed switching angles tend to be located at 0 and pi/2, which makes the harmonic suppression effect worse. To realize a good harmonic suppression effect for HF-MLIs with a large number of levels, an interior-point-method-based switching angle computation method is proposed in this paper. With the aid of the interior point method (IPM), the constraints of switching angles are combined with the harmonic function in the objective function through a penalty function. The iteration is divided into the inner loop and the outer loop. The switching angles are computed in the inner loop and the weight of the penalty function is updated in the outer loop. The penalty function can keep the switching angles away from constraints. When compared with conventional methods, the proposed method has a higher accuracy, a shorter execution time and better harmonic suppression effect when computing the switching angles of MLIs with more than 25 levels. The harmonics from 9 to 19th-order of the proposed method are suppressed to less than 0.1%, which is experimentally verified on a single-phase 49-level HF-MLI.
引用
收藏
页码:1229 / 1240
页数:12
相关论文
共 50 条
  • [31] A Grid-Connected Cascaded H-Bridge Multilevel Converter with Quasi Seven-Level Selective Harmonic Elimination
    Fakhry, Mina. G.
    Massoud, A.
    Ahmed, S.
    2015 4TH INTERNATIONAL CONFERENCE ON ELECTRIC POWER AND ENERGY CONVERSION SYSTEMS (EPECS), 2015,
  • [32] Model Predictive Control Based Selective Harmonic Mitigation Technique for Multilevel Cascaded H-bridge Converters
    Aggrawal, Himanshu
    Leon, Jose I.
    Franquelo, Leopoldo G.
    Kouro, Samir
    Garg, Prashant
    Rodriguez, Jose
    IECON 2011: 37TH ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2011, : 4427 - 4432
  • [33] Selective Harmonic Mitigation Based on Closest Level Modulation Scheme for Cascaded H-Bridge Multilevel Inverter
    Zaid, Mohammad
    Sarwar, Adil
    Tayyab, Mohammad
    Iqbal, Atif
    Bakhsh, Farhad Ilahi
    Baghel, Anshul
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2023,
  • [34] Harmonic elimination of cascaded H-bridge multilevel inverter based active power filter controlled by intelligent techniques
    Rao, G. Nageswara
    Raju, P. Sangameswara
    Sekhar, K. Chandra
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2014, 61 : 56 - 63
  • [35] Selective Harmonic Elimination PWM for Cascaded H-bridge Multilevel Inverter with Wide Output Voltage Range Using PSO Algorithm
    Sadoughi, Milad
    Zakerian, Ali
    Pourdadashnia, Amirhossein
    Farhadi-Kangarlu, Mohammad
    2021 IEEE TEXAS POWER AND ENERGY CONFERENCE (TPEC), 2021, : 30 - 35
  • [36] Control of a Transformer-less Cascaded H-bridge Based STATCOM Using Low-Frequency Selective Harmonic Elimination Technique
    Neyshabouri, Y.
    Iman-Eini, H.
    Farhangi, Sh.
    2013 12TH INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING (EEEIC 2013), 2013, : 495 - 500
  • [37] Most Valuable Player based selective harmonic elimination in a cascaded H-bridge inverter for wide operating range
    Sarwar, Adil
    Yadav, Raj Kumar
    Asim, Mohammed
    Saxena, Dipti
    Jain, Chandra Prakash
    Mewara, Hari Shankar
    INTERNATIONAL JOURNAL OF EMERGING ELECTRIC POWER SYSTEMS, 2023, 24 (05) : 619 - 634
  • [38] An Improved Artificial Neural Network-Based Approach for Total Harmonic Distortion Reduction in Cascaded H-Bridge Multilevel Inverters
    Ghadi, Yazeed Yasin
    Iqbal, Muhammad Sajid
    Adnan, Muhammad
    Amjad, Kashif
    Ahmad, Ijaz
    Farooq, Umer
    IEEE ACCESS, 2023, 11 : 127348 - 127363
  • [39] A Phase Shift Selective Harmonic Elimination Method for balancing capacitor voltages in a seven level Cascaded H-Bridge Rectifier
    Watson, Alan J.
    Wheeler, Patrick W.
    Clare, Jon C.
    EPE: 2009 13TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS, VOLS 1-9, 2009, : 1326 - 1334
  • [40] Analytical Method for Pattern Generation in Five-Level Cascaded H-Bridge Inverter Using Selective Harmonic Elimination
    Buccella, Concettina
    Cecati, Carlo
    Cimoroni, Maria Gabriella
    Razi, Kaveh
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2014, 61 (11) : 5811 - 5819