Measurement of proximal contact of single crowns to assess interproximal relief: A pilot study

被引:1
|
作者
Kim, Daniel S.
Lau, Le Na [1 ]
Kim, Jong-Woong [1 ]
Yeo, In-Sung Luke [1 ,2 ]
机构
[1] Seoul Natl Univ, Sch Dent, Dept Prosthodont, 101 Daehak Ro, Seoul 03080, South Korea
[2] Seoul Natl Univ, Dent Res Inst, 101 Daehak Ro, Seoul 03080, South Korea
关键词
CAD; -CAM; Crowns; Interproximal relief; Prosthesis fitting; Proximal surface adjustment; NEURAL-NETWORK; RESTORATIONS; FABRICATION; ADJUSTMENT; IMPLANTS; SURVIVAL;
D O I
10.1016/j.heliyon.2023.e20403
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: It is common for dental technicians to adjust the proximal surface of adjacent teeth on casts when fabricating single crowns. However, whether the accuracy of the proximal contact is affected if this step is eliminated is unclear. Objective: To evaluate the accuracy of the proximal contact of single crowns for mandibular first molars fabricated from four different restorative materials, without adjustment of the proximal surface of the adjacent teeth by the laboratory/dental technician. Methods: This study was in vitro; all the clinical procedures were conducted on a dentoform. The mandibular first molar tooth on the dentoform was prepared using diamond burs and a high speed handpiece. Twenty single crowns were fabricated, five for each group (monolithic zirconia, lithium disilicate, metal ceramic, and cast gold). No proximal surface adjacent to the definitive crowns was adjusted for tight contact in the dental laboratory. Both the qualitative analyses, using dental floss and shimstock, and the quantitative analyses, using a stereo microscope, were performed to evaluate the accuracy of the proximal contact of the restoration with the adjacent teeth. In the quantitative analysis, one-way analysis of variance was used to compare mean values at a significance level of 0.05. Results: In quantitative analysis, the differences between the proximal contact tightness of the four groups was not statistically significant (P = 0.802 for mesial contacts, P = 0.354 for distal contacts). In qualitative analysis, in most crowns, dental floss passed through the contact with tight resistance and only one film of shimstock could be inserted between the adjacent teeth and the restoration. However, one specimen from the cast gold crown had open contact. Conclusions: Even without proximal surface adjustment of the adjacent teeth during the crown fabrication process, adequate proximal contact tightness between the restoration and adjacent teeth could be achieved.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Clinical Results and Technical Complications of Posterior Implant-Supported Modified Monolithic Zirconia Single Crowns and Short-Span Fixed Dental Prostheses: A 2-Year Pilot Study
    Cheng, Chih-Wen
    Chien, Chia-Hui
    Chen, Chun-Jung
    Papaspyridakos, Panos
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2018, 27 (02): : 108 - 114
  • [42] A pilot study examining the suitability of the mental arithmetic task and single-item measures of affective states to assess affective, physiological, and attention restoration at a wooden desk
    Lipovac, Dean
    Zitnik, Jure
    Burnard, Michael D.
    JOURNAL OF WOOD SCIENCE, 2022, 68 (01)
  • [43] Direct Measurement of Proximal Isovelocity Surface Area by Single-Beat Three-Dimensional Color Doppler Echocardiography in Mitral Regurgitation: A Validation Study
    Alberto de Agustin, Jose
    Marcos-Alberca, Pedro
    Fernandez-Golfin, Covadonga
    Goncalves, Alexandra
    Feltes, Gisela
    Javier Nunez-Gil, Ivan
    Almeria, Carlos
    Luis Rodrigo, Jose
    Perez de Isla, Leopoldo
    Macaya, Carlos
    Zamorano, Jose
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2012, 25 (08) : 815 - 823
  • [44] Preliminary results of a single-arm pilot study to assess the safety and efficacy of visnadine, prenylflavonoids and bovine colostrum in postmenopausal sexually active women affected by vulvovaginal atrophy
    Lagana, Antonio Simone
    Vitale, Salvatore Giovanni
    Stojanovska, Lily
    Lambrinoudaki, Irene
    Apostolopoulos, Vasso
    Chiofalo, Benito
    Rizzo, Laura
    Basile, Francesca
    MATURITAS, 2018, 109 : 78 - 80
  • [45] Reliability testing of the patellofemoral joint reaction force (PFJRF) measurement in taped and untaped patellofemoral conditions during single leg squatting: A pilot study
    Mostamand, Javid
    Bader, Dan L.
    Hudson, Zoe
    JOURNAL OF BODYWORK AND MOVEMENT THERAPIES, 2011, 15 (04) : 502 - 506
  • [46] Impact of 18F standard PET EARL-harmonization on functional volume measurement: a pilot single-center phantom study
    Khamadeeva, G.
    Khalimon, A.
    Nikiforuk, A.
    Onishchenko, S.
    Khodzhibekova, M.
    Leontyev, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 : S718 - S719
  • [47] Proximal heat stress up-regulates angiopoietin-1 in fingers and reduces the severity of Raynaud's phenomenon in systemic sclerosis: a single-centre pilot study
    Shima, Yoshihito
    Watanabe, Akane
    Inoue, Nobuto
    Maruyama, Tetsuya
    Kunitomo, Eiji
    Hamano, Kunihiko
    Kawanishi, Takashi
    Takasugi, Masashi
    Kumanogoh, Atsushi
    MODERN RHEUMATOLOGY, 2022, 32 (02) : 351 - 357
  • [48] Acute administration of a single dose of valsartan improves left ventricular functions:: a pilot study to assess the role of tissue velocity echocardiography in patients with systemic arterial hypertension in the TVE-valsartan study I
    Govind, Satish C.
    Brodin, Lars-Ake
    Nowak, Jacek
    Ramesh, S. S.
    Saha, Samir K.
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2006, 26 (06) : 351 - 356
  • [49] Video-based assessment (VBA) of an open, simulated orthopedic surgical procedure: a pilot study using a single-angle camera to assess surgical skill and decision making
    Al-Hubaishi, Obaid
    Hillier, Troy
    Gillis, Megan
    Oxner, William
    Trenholm, Andrew
    Richardson, Glen
    Leighton, Ross
    Glennie, Andrew
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [50] Video-based assessment (VBA) of an open, simulated orthopedic surgical procedure: a pilot study using a single-angle camera to assess surgical skill and decision making
    Obaid Al-Hubaishi
    Troy Hillier
    Megan Gillis
    William Oxner
    Andrew Trenholm
    Glen Richardson
    Ross Leighton
    Andrew Glennie
    Journal of Orthopaedic Surgery and Research, 18