Measurement of proximal contact of single crowns to assess interproximal relief: A pilot study

被引:1
|
作者
Kim, Daniel S.
Lau, Le Na [1 ]
Kim, Jong-Woong [1 ]
Yeo, In-Sung Luke [1 ,2 ]
机构
[1] Seoul Natl Univ, Sch Dent, Dept Prosthodont, 101 Daehak Ro, Seoul 03080, South Korea
[2] Seoul Natl Univ, Dent Res Inst, 101 Daehak Ro, Seoul 03080, South Korea
关键词
CAD; -CAM; Crowns; Interproximal relief; Prosthesis fitting; Proximal surface adjustment; NEURAL-NETWORK; RESTORATIONS; FABRICATION; ADJUSTMENT; IMPLANTS; SURVIVAL;
D O I
10.1016/j.heliyon.2023.e20403
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: It is common for dental technicians to adjust the proximal surface of adjacent teeth on casts when fabricating single crowns. However, whether the accuracy of the proximal contact is affected if this step is eliminated is unclear. Objective: To evaluate the accuracy of the proximal contact of single crowns for mandibular first molars fabricated from four different restorative materials, without adjustment of the proximal surface of the adjacent teeth by the laboratory/dental technician. Methods: This study was in vitro; all the clinical procedures were conducted on a dentoform. The mandibular first molar tooth on the dentoform was prepared using diamond burs and a high speed handpiece. Twenty single crowns were fabricated, five for each group (monolithic zirconia, lithium disilicate, metal ceramic, and cast gold). No proximal surface adjacent to the definitive crowns was adjusted for tight contact in the dental laboratory. Both the qualitative analyses, using dental floss and shimstock, and the quantitative analyses, using a stereo microscope, were performed to evaluate the accuracy of the proximal contact of the restoration with the adjacent teeth. In the quantitative analysis, one-way analysis of variance was used to compare mean values at a significance level of 0.05. Results: In quantitative analysis, the differences between the proximal contact tightness of the four groups was not statistically significant (P = 0.802 for mesial contacts, P = 0.354 for distal contacts). In qualitative analysis, in most crowns, dental floss passed through the contact with tight resistance and only one film of shimstock could be inserted between the adjacent teeth and the restoration. However, one specimen from the cast gold crown had open contact. Conclusions: Even without proximal surface adjustment of the adjacent teeth during the crown fabrication process, adequate proximal contact tightness between the restoration and adjacent teeth could be achieved.
引用
收藏
页数:8
相关论文
共 50 条
  • [11] Comparison of diagnostic ability of storage phosphor plate in detecting proximal caries with direct measurement by stereomicroscope: a pilot study
    Vivek, Velayudhannair
    Thomas, Sunila
    Nair, Bindu J.
    Vineet, Alex Daniel
    Thomas, Jincy
    Ranimol, Prasanna
    Vijayan, Aswathy K.
    CLINICS AND PRACTICE, 2015, 5 (03)
  • [12] The identification of trichoscopic features of allergic scalp contact dermatitis: a pilot-study of a single center
    Starace, Michela
    Bruni, Francesca
    Marcondes, Maria T.
    Alessandrini, Aurora
    Piraccini, Bianca M.
    ITALIAN JOURNAL OF DERMATOLOGY AND VENEREOLOGY, 2023, 158 (04) : 334 - 340
  • [13] Continuous non-invasive measurement of urethral perfusion to assess microcirculation: A pilot study in cardiac surgery patients
    Cazenave, Laure
    Ferraris, Arnaud
    Jacquet-Lagreze, Matthias
    Allaouchiche, Bernard
    Fellahi, Jean-Luc
    ANAESTHESIA CRITICAL CARE & PAIN MEDICINE, 2021, 40 (03)
  • [14] Digital measurement of ocular microtremor in Parkinson's disease: Protocol for a pilot study to assess reliability and clinical validation
    Graham, Lisa
    Vitorio, Rodrigo
    Walker, Richard
    Godfrey, Alan
    Morris, Rosie
    Stuart, Samuel
    PLOS ONE, 2025, 20 (01):
  • [15] In vivo measurement of pediatric extracorporeal oxygenator insensible losses; a single center pilot study
    Suttles, Tess L.
    Poe, John
    Neumayr, Tara M.
    Said, Ahmed S.
    FRONTIERS IN PEDIATRICS, 2024, 12
  • [16] Occlusal contact and clearance of posterior implant-supported single crowns designed by two different methods: a self-controlled study
    Mingzhu He
    Tingting Pu
    Qian Ding
    Yao Sun
    Pengfei Wang
    Yuchun Sun
    Lei Zhang
    BMC Oral Health, 23
  • [17] Occlusal contact and clearance of posterior implant-supported single crowns designed by two different methods: a self-controlled study
    He, Mingzhu
    Pu, Tingting
    Ding, Qian
    Sun, Yao
    Wang, Pengfei
    Sun, Yuchun
    Zhang, Lei
    BMC ORAL HEALTH, 2023, 23 (01)
  • [18] Single fascia iliaca compartment block for pain relief in patients with fractured neck of femur in the emergency department: a pilot study
    Elkhodair, Samer
    Mortazavi, Jamal
    Chester, Adam
    Pereira, Mathew
    EUROPEAN JOURNAL OF EMERGENCY MEDICINE, 2011, 18 (06) : 340 - 343
  • [19] Pilot study to assess the validity of the single assessment process as a screening tool for dental treatment needs in older people
    Heyes, Gill
    Robinson, Peter G.
    GERODONTOLOGY, 2008, 25 (03) : 142 - 146
  • [20] A pilot study for detecting release instant using a single inertia measurement unit in shot put
    Kato, Tadahioko
    Maeda, Kei
    Mizushima, Jun
    Ohyama-Byun, Keigo
    Adachi, Takahiro
    Fukuda, Jun
    JOURNAL OF HUMAN SPORT AND EXERCISE, 2024, 19 (04): : 1042 - 1051