A Study of Fixed Current and Automatic Tube Current Modulation at a Fixed Low Tube Voltage in Low-dose Computed Tomography (CT) Imaging of Infant Lungs

被引:0
|
作者
Chen, Wushuang [1 ]
Tang, Shilong [1 ]
Xu, Zhen [1 ]
Chen, Xin [1 ]
Zheng, Yinglan [1 ]
He, Ling [1 ]
机构
[1] Chongqing Med Univ, Childrens Hosp, Dept Radiol, Chongqing, Peoples R China
关键词
Multilayer Spiral CT; Infant Chest; Low Dose; iDose4 Iterative Reconstruction; STATISTICAL ITERATIVE RECONSTRUCTION; QUALITY; CHEST;
D O I
10.5812/iranjradiol-126362
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: With the development of computed tomography (CT) technology, the number of infants undergoing CT examination has increased. Recently, problems associated with radiation exposure have attracted the public attention, and low-dose CT examination has become the research focus. Objectives: This study aimed to explore the feasibility of a fixed ultralow tube current combined with iDose(4) iterative reconstruction at a low tube voltage (80 kV) in low-dose CT scanning of infant lungs. Patients and Methods: Ninety infants, aged 0 - 3 years, undergoing enhanced chest CT scan (including plain CT scan and arterial scan), were included in the experimental group. In the experimental group, plain CT scan was performed at 80 kV under a fixed tube current (30 mA), and arterial phase CT scan was carried out at 80 kV with automatic tube current modulation (30 - 150 mA). Meanwhile, 90 infants, aged 0 - 3 years, undergoing non-enhanced chest CT scan, were randomly recruited as the control group. For the control group, plain CT scan was performed at 80 kV with automatic tube current modulation (30-150 mA). In each examination, the iDose4 iterative reconstruction technique was used for reconstruction. The volume CT dose index (CTDIvol), dose-length product (DLP), effective dose (ED, measured using a 32-cm diameter phantom), signal-to-noise ratio (SNR), and overall subjective quality of plain CT scans were analyzed and compared between the experimental and control groups. Results: Regarding the radiation dose in different age groups, the ED (mSv) was significantly lower in the experimental group compared to the control group (0-1-year-old subgroup: 0.48 +/- 0.05 mSv in the experimental group vs. 0.91 +/- 0.19 mSv in the control group, P < 0.05; 1-2-year-old subgroup: 0.50 +/- 0.01 mSv in the experimental group vs. 0.75 +/- 0.10 mSv in the control group, P < 0.05; and 2-3-year-old subgroup: 0.46 +/- 0.05 mSv in the experimental group vs. 0.79 +/- 0.11 mSv in the control group, P < 0.05). The image SNR was higher in the control group compared to the experimental group (P < 0.05), while the difference in subjective image quality was not significant between the experimental and control groups (P < 0.05). Conclusion: The chest CT examination of infants, aged 0 - 3 years, at a low tube voltage (80 kV) and a fixed tube current (30 mA), combined with the iDose4 iterative reconstruction technique, and the obtained images met the diagnostic criteria...
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Dose conversion coefficients for paediatric CT examinations with automatic tube current modulation
    Schlattl, H.
    Zankl, M.
    Becker, J.
    Hoeschen, C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (20): : 6309 - 6326
  • [32] INFLUENCE OF LOCALIZER AND SCAN DIRECTION ON THE DOSE-REDUCING EFFECT OF AUTOMATIC TUBE CURRENT MODULATION IN COMPUTED TOMOGRAPHY
    Franck, C.
    Bacher, K.
    RADIATION PROTECTION DOSIMETRY, 2016, 169 (1-4) : 136 - 142
  • [33] Quantitative and qualitative evaluation of low-dose craniocervical computed tomography angiography with a lower tube voltage protocol
    Chen, Po-An
    Chen, Chih-Wei
    Chou, Chiung-Chen
    Fu, Jui-Hsun
    Wang, Po-Chin
    Hsu, Shuo-Hsiu
    Lai, Ping-Hong
    ACTA RADIOLOGICA, 2019, 60 (10) : 1380 - 1389
  • [34] Emphysema Quantification in Inflation-Fixed Lungs Using Low-Dose Computed Tomography and 3He Magnetic Resonance Imaging
    Gierada, David S.
    Woods, Jason C.
    Jacob, Richard E.
    Bierhals, Andrew J.
    Choong, Cliff K.
    Bartel, Seth T.
    Chang, Yulin V.
    Das, Nitin A.
    Hong, Cheng
    Lutey, Barbara A.
    Ritter, Jon H.
    Pilgram, Thomas K.
    Cooper, Joel D.
    Patterson, G. Alexander
    Battafarano, Richard J.
    Meyers, Bryan F.
    Yablonskiy, Dmitriy A.
    Conradi, Mark S.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2010, 34 (05) : 773 - 779
  • [35] Dose study of electrocardiogram automatic tube current modulation technology in prospective coronary computed tomography angiography scans of overweight patients
    He, Guiru
    Liu, Xiaopei
    Liu, Yan
    Wang, Wei
    Ke, Zhiliang
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2015, 9 (06) : 2384 - 2388
  • [36] Quantitative assessment of image noise and streak artifact on CT image: Comparison of z-axis automatic tube current modulation technique with fixed tube current technique
    Imai, Kuniharu
    Ikeda, Mitsuru
    Enchi, Yukihiro
    Niimi, Takanaga
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2009, 33 (05) : 353 - 358
  • [37] Attenuation-based Automatic Tube Voltage Selection and Tube Current Modulation for Dose Reduction at Contrast-enhanced Liver CT
    Lee, Kyung Hee
    Lee, Jeong Min
    Moon, Sung Kyoung
    Baek, Jee Hyun
    Park, Ji Hoon
    Flohr, Thomas G.
    Kim, Kyung Won
    Kim, Soo Jin
    Han, Joon Koo
    Choi, Byung Ihn
    RADIOLOGY, 2012, 265 (02) : 437 - 447
  • [38] Fetal Dose Estimates for Tube Current Modulated (TCM) and Fixed Tube Current (FTC) Abdominal/Pelvic CT Examinations of Pregnant Patients
    Hardy, A.
    Bostani, M.
    Angel, E.
    Cagnon, C.
    McNitt-Gray, M.
    MEDICAL PHYSICS, 2019, 46 (06) : E519 - E519
  • [39] Estimating fetal dose from tube current-modulated (TCM) and fixed tube current (FTC) abdominal/pelvis CT examinations
    Hardy, Anthony J.
    Angel, Erin
    Bostani, Maryam
    Cagnon, Chris
    McNitt-Gray, Michael
    MEDICAL PHYSICS, 2019, 46 (06) : 2729 - 2743
  • [40] The feasibility of low-concentration contrast and low tube voltage in computed tomography perfusion imaging: an animal study
    Pan, Yuning
    Song, Aiqin
    Bu, Shizhong
    Chen, Zhaoqian
    Huang, Qiuli
    Li, Aijing
    BIOSCIENCE REPORTS, 2018, 38