Comparison of Low-Dose Computed Tomography Versus Conventional-Dose Computed Tomography in the Evaluation of Distal Radius Fractures

被引:0
|
作者
Zeng, Steven L. [1 ,5 ]
Grier, A. Jordan [2 ]
Langdell, Hannah C. [3 ]
Blevins, Kier M. [2 ]
Tian, William M. [1 ]
French, Robert J. [4 ]
Mithani, Suhail K. [3 ]
Hammert, Warren C. [2 ]
Klifto, Christopher S. [2 ]
机构
[1] Duke Univ, Sch Med, Durham, NC USA
[2] Duke Univ, Dept Orthoped Surg, Durham, NC USA
[3] Duke Univ, Div Plast Maxillofacial & Oral Surg, Durham, NC USA
[4] Duke Univ, Dept Radiol, Durham, NC USA
[5] 104 East Hammond St,40 Duke Med Circle, Durham, NC 27704 USA
关键词
distal radius; fracture/dislocation; diagnosis; radiology; specialty; CUMULATIVE RADIATION-EXPOSURE; INDUCED CANCER-RISKS; INTRAARTICULAR FRACTURES; CT;
D O I
10.1177/15589447241232016
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Distal radius fractures (DRFs) are common upper extremity fractures and often require surgical fixation when they are intraarticular. Preoperative computed tomography (CT) has emerged as a surgical planning tool to evaluate intraarticular DRFs. Although CT affords additional details, patients receive higher radiation doses than standard radiographs. We aim to develop a low-dose CT (LDCT) protocol, relative to the institutional standard-dose CT wrist for intraarticular DRFs although providing adequate detail for surgical decision-making.Methods: A single-institution prospective study was conducted on patients with intraarticular DRFs who underwent closed reduction and below-elbow splinting who otherwise would undergo wrist CT. Observations were defined as total measurements taken, with each view undergoing 44 measurements. Patients underwent 2 scans with a standard dose and a 10x dose reduction. Articular step and gap measurements were recorded in the sagittal and coronal images.Results: A total of 11 patients were enrolled (7 women and 4 men). The mean age was 55 years (SD = 20.1). There were a total of 4 reviewers: 1 attending surgeon, 2 resident physicians, and 1 student. When comparing LDCT and conventional-dose CT (CDCT), there were no significant differences in step and gap measurements across all reviewers.Conclusion: This study demonstrated that LDCT provides comparable imaging quality for surgical planning as a CDCT without significant diagnostic decay in the setting of DRFs. This comes with the added benefit of a 10-fold reduction in radiation exposure. These results suggest that LDCT is an opportunity to reduce effective radiation in patients although providing beneficial preoperative imaging.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Low-Dose Cardiovascular Computed Tomography: Where Are the Limits?
    Schoenhagen, Paul
    Thompson, Carla M.
    Halliburton, Sandra S.
    CURRENT CARDIOLOGY REPORTS, 2012, 14 (01) : 17 - 23
  • [32] Lung cancer screening with low-dose computed tomography
    Seijo Maceiras, Luis M.
    MEMO-MAGAZINE OF EUROPEAN MEDICAL ONCOLOGY, 2014, 7 (01) : 6 - 9
  • [33] Lung cancer screening with low-dose computed tomography
    Hartman, TE
    Swensen, SJ
    SEMINARS IN ROENTGENOLOGY, 2003, 38 (01) : 34 - 38
  • [34] Lung Cancer Screening With Low-Dose Computed Tomography
    Reck, Martin
    Dettmer, Sabine
    Kauczor, Hans-Ulrich
    Kaaks, Rudolf
    Reinmuth, Niels
    Vogel-Claussen, Jens
    DEUTSCHES ARZTEBLATT INTERNATIONAL, 2023, 120 (23): : 387 - +
  • [35] Low-Dose Cardiovascular Computed Tomography: Where are the Limits?
    Paul Schoenhagen
    Carla M. Thompson
    Sandra S. Halliburton
    Current Cardiology Reports, 2012, 14 : 17 - 23
  • [36] Low-Dose Computed Tomography Screening for Lung Cancer
    Welch, Laura S.
    Madtes, David
    Ringen, Knut
    ANNALS OF INTERNAL MEDICINE, 2015, 162 (06) : 459 - 460
  • [37] A sinogram denoising algorithm for low-dose computed tomography
    Davood Karimi
    Pierre Deman
    Rabab Ward
    Nancy Ford
    BMC Medical Imaging, 16
  • [38] Lung cancer screening with low-dose computed tomography
    Luis M. Seijo Maceiras
    memo - Magazine of European Medical Oncology, 2014, 7 (1) : 6 - 9
  • [39] Screening for Lung Cancer With Low-Dose Computed Tomography
    Miller, Anthony B.
    ONCOLOGIST, 2013, 18 (08): : 897 - 899
  • [40] Screening for Lung Cancer With Low-Dose Computed Tomography
    Brodersen, John
    Dirksen, Asger
    Pedersen, Jesper Holst
    ANNALS OF INTERNAL MEDICINE, 2014, 160 (03) : 211 - 212