Comparison of Low-Dose Computed Tomography Versus Conventional-Dose Computed Tomography in the Evaluation of Distal Radius Fractures

被引:0
|
作者
Zeng, Steven L. [1 ,5 ]
Grier, A. Jordan [2 ]
Langdell, Hannah C. [3 ]
Blevins, Kier M. [2 ]
Tian, William M. [1 ]
French, Robert J. [4 ]
Mithani, Suhail K. [3 ]
Hammert, Warren C. [2 ]
Klifto, Christopher S. [2 ]
机构
[1] Duke Univ, Sch Med, Durham, NC USA
[2] Duke Univ, Dept Orthoped Surg, Durham, NC USA
[3] Duke Univ, Div Plast Maxillofacial & Oral Surg, Durham, NC USA
[4] Duke Univ, Dept Radiol, Durham, NC USA
[5] 104 East Hammond St,40 Duke Med Circle, Durham, NC 27704 USA
关键词
distal radius; fracture/dislocation; diagnosis; radiology; specialty; CUMULATIVE RADIATION-EXPOSURE; INDUCED CANCER-RISKS; INTRAARTICULAR FRACTURES; CT;
D O I
10.1177/15589447241232016
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Distal radius fractures (DRFs) are common upper extremity fractures and often require surgical fixation when they are intraarticular. Preoperative computed tomography (CT) has emerged as a surgical planning tool to evaluate intraarticular DRFs. Although CT affords additional details, patients receive higher radiation doses than standard radiographs. We aim to develop a low-dose CT (LDCT) protocol, relative to the institutional standard-dose CT wrist for intraarticular DRFs although providing adequate detail for surgical decision-making.Methods: A single-institution prospective study was conducted on patients with intraarticular DRFs who underwent closed reduction and below-elbow splinting who otherwise would undergo wrist CT. Observations were defined as total measurements taken, with each view undergoing 44 measurements. Patients underwent 2 scans with a standard dose and a 10x dose reduction. Articular step and gap measurements were recorded in the sagittal and coronal images.Results: A total of 11 patients were enrolled (7 women and 4 men). The mean age was 55 years (SD = 20.1). There were a total of 4 reviewers: 1 attending surgeon, 2 resident physicians, and 1 student. When comparing LDCT and conventional-dose CT (CDCT), there were no significant differences in step and gap measurements across all reviewers.Conclusion: This study demonstrated that LDCT provides comparable imaging quality for surgical planning as a CDCT without significant diagnostic decay in the setting of DRFs. This comes with the added benefit of a 10-fold reduction in radiation exposure. These results suggest that LDCT is an opportunity to reduce effective radiation in patients although providing beneficial preoperative imaging.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Image Fusion for Low-Dose Computed Tomography Reconstruction
    Ma, Jianhua
    Huang, Jing
    Liang, Zhengrong
    Zhang, Hua
    Fan, Yi
    Feng, Qianjin
    Chen, Wufan
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 4239 - 4243
  • [22] Subsolid Pulmonary Nodules in Low-dose Computed Tomography
    Hekmat, K.
    Bruns, C. J.
    CHIRURG, 2019, 90 (Suppl 2): : S113 - S113
  • [23] VARIATIONAL DEEP LEARNING FOR LOW-DOSE COMPUTED TOMOGRAPHY
    Kobler, Erich
    Muckley, Matthew
    Chen, Baiyu
    Knoll, Florian
    Hammernik, Kerstin
    Pock, Thomas
    Sodickson, Daniel
    Otazo, Ricardo
    2018 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING (ICASSP), 2018, : 6687 - 6691
  • [24] Lung Cancer Screening with Low-Dose Computed Tomography
    Chiles, Caroline
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2014, 52 (01) : 27 - +
  • [25] Subsolid Pulmonary Nodules in Low-Dose Computed Tomography
    Hekmat, K.
    Bruns, C. J.
    CHIRURG, 2018, 89 (12): : 1008 - 1008
  • [26] Low-Dose Computed Tomography for Lung Cancer Screening: The Protocol and The Dose
    McDermott, Shaunagh
    Kaira, Mannudeep K.
    SEMINARS IN ROENTGENOLOGY, 2017, 52 (03) : 132 - 136
  • [27] Lung Cancer Screening With Low-Dose Computed Tomography
    Loebig, Stephanie
    Haegele, Patricia
    Seizer, Peter
    DEUTSCHES ARZTEBLATT INTERNATIONAL, 2023, 120 (41):
  • [28] A sinogram denoising algorithm for low-dose computed tomography
    Karimi, Davood
    Deman, Pierre
    Ward, Rabab
    Ford, Nancy
    BMC MEDICAL IMAGING, 2016, 16
  • [29] Future of Low-Dose Computed Tomography and Dual-Energy Computed Tomography in Axial Spondyloarthritis
    Torsten Diekhoff
    Kay Geert A. Hermann
    Robert G. Lambert
    Current Rheumatology Reports, 2022, 24 : 198 - 205
  • [30] Low-dose computed tomography in prior asbestos workers
    Roberts, H.
    LUNG CANCER, 2006, 54 : S3 - S3