ADEPT: Accurate Diffusion Echo-Planar imaging with multi-contrast shoTs

被引:3
|
作者
Shafieizargar, Banafshe [1 ,2 ]
Jeurissen, Ben [1 ,2 ]
Poot, Dirk H. J. [3 ]
Klein, Stefan [3 ]
Van Audekerke, Johan [2 ,4 ]
Verhoye, Marleen [2 ,4 ]
den Dekker, Arnold J. [1 ,2 ]
Sijbers, Jan [1 ,2 ]
机构
[1] Univ Antwerp, Dept Phys, Iimec Vis Lab, Univ Pl 1,DN 103, B-2610 Antwerp, Belgium
[2] Univ Antwerp, NEURO Res Ctr Excellence, Antwerp, Belgium
[3] Erasmus MC, Dept Radiol & Nucl Med, Biomed Imaging Grp Rotterdam, Rotterdam, Netherlands
[4] Univ Antwerp, Dept Biomed Sci, Bioimaging Lab, Antwerp, Belgium
基金
欧盟地平线“2020”;
关键词
diffusion MRI; model-based reconstruction; multi-shot EPI; phase correction; QMRI; MODEL-BASED RECONSTRUCTION; RICIAN DISTRIBUTION; WEIGHTED-MRI; RESOLUTION; MOTION; CONVERGENCE; ARTIFACTS; SENSE; EPI;
D O I
10.1002/mrm.29398
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To introduce a novel imaging and parameter estimation framework for accurate multi-shot diffusion MRI. Theory and Methods We propose a new framework called ADEPT (Accurate Diffusion Echo-Planar imaging with multi-contrast shoTs) that enables fast diffusion MRI by allowing diffusion contrast settings to change between shots in a multi-shot EPI acquisition (i.e., intra-scan modulation). The framework estimates diffusion parameter maps directly from the acquired intra-scan modulated k-space data, while simultaneously accounting for shot-to-shot phase inconsistencies. The performance of the estimation framework is evaluated using Monte Carlo simulation studies and in-vivo experiments and compared to that of reference methods that rely on parallel imaging for shot-to-shot phase correction. Results Simulation and real-data experiments show that ADEPT yields more accurate and more precise estimates of the diffusion metrics in multi-shot EPI data in comparison with the reference methods. Conclusion ADEPT allows fast multi-shot EPI diffusion MRI without significantly degrading the accuracy and precision of the estimated diffusion maps.
引用
下载
收藏
页码:396 / 410
页数:15
相关论文
共 50 条
  • [41] DIFFUSION-WEIGHTED INTERLEAVED ECHO-PLANAR TECHNIQUES WITH NAVIGATION FOR IMAGING STROKE
    BUTTS, K
    DECRESPIGNY, AC
    MOSELEY, ME
    RADIOLOGY, 1995, 197 : 390 - 390
  • [42] Qualitative and quantitative comparison of image quality between single-shot echo-planar and interleaved multi-shot echo-planar diffusion-weighted imaging in female pelvis
    He An
    Xiaodong Ma
    Ziyi Pan
    Hua Guo
    Elaine Yuen Phin Lee
    European Radiology, 2020, 30 : 1876 - 1884
  • [43] INTERLEAVED ECHO-PLANAR PHASE-CONTRAST ANGIOGRAPHY
    MCKINNON, GC
    MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (06) : 682 - 685
  • [44] LIMITS TO NEURAL STIMULATION IN ECHO-PLANAR IMAGING
    MANSFIELD, P
    HARVEY, PR
    MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (06) : 746 - 758
  • [45] Reducing flow artifacts in echo-planar imaging
    Pat, GTL
    Meyer, CH
    Pauly, JM
    Nishimura, DG
    MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (03) : 436 - 447
  • [46] Echo-planar rotating-frame imaging
    Casanova, F
    Robert, H
    Perlo, J
    Pusiol, D
    JOURNAL OF MAGNETIC RESONANCE, 2003, 162 (02) : 396 - 401
  • [47] Multiple-shot echo-planar imaging
    Hennel, F
    CONCEPTS IN MAGNETIC RESONANCE, 1997, 9 (01): : 43 - 58
  • [48] Qualitative and quantitative comparison of image quality between single-shot echo-planar and interleaved multi-shot echo-planar diffusion-weighted imaging in female pelvis
    An, He
    Ma, Xiaodong
    Pan, Ziyi
    Guo, Hua
    Lee, Elaine Yuen Phin
    EUROPEAN RADIOLOGY, 2020, 30 (04) : 1876 - 1884
  • [49] DUAL-ECHO INTERLEAVED ECHO-PLANAR IMAGING OF THE BRAIN
    SLAVIN, GS
    BUTTS, K
    RYDBERG, JN
    JACK, CR
    RIEDERER, SJ
    MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (02) : 264 - 270
  • [50] Volumetric multishot echo-planar spectroscopic imaging
    Tyszka, JM
    Mamelak, AN
    MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (02) : 219 - 227