ADEPT: Accurate Diffusion Echo-Planar imaging with multi-contrast shoTs

被引:3
|
作者
Shafieizargar, Banafshe [1 ,2 ]
Jeurissen, Ben [1 ,2 ]
Poot, Dirk H. J. [3 ]
Klein, Stefan [3 ]
Van Audekerke, Johan [2 ,4 ]
Verhoye, Marleen [2 ,4 ]
den Dekker, Arnold J. [1 ,2 ]
Sijbers, Jan [1 ,2 ]
机构
[1] Univ Antwerp, Dept Phys, Iimec Vis Lab, Univ Pl 1,DN 103, B-2610 Antwerp, Belgium
[2] Univ Antwerp, NEURO Res Ctr Excellence, Antwerp, Belgium
[3] Erasmus MC, Dept Radiol & Nucl Med, Biomed Imaging Grp Rotterdam, Rotterdam, Netherlands
[4] Univ Antwerp, Dept Biomed Sci, Bioimaging Lab, Antwerp, Belgium
基金
欧盟地平线“2020”;
关键词
diffusion MRI; model-based reconstruction; multi-shot EPI; phase correction; QMRI; MODEL-BASED RECONSTRUCTION; RICIAN DISTRIBUTION; WEIGHTED-MRI; RESOLUTION; MOTION; CONVERGENCE; ARTIFACTS; SENSE; EPI;
D O I
10.1002/mrm.29398
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To introduce a novel imaging and parameter estimation framework for accurate multi-shot diffusion MRI. Theory and Methods We propose a new framework called ADEPT (Accurate Diffusion Echo-Planar imaging with multi-contrast shoTs) that enables fast diffusion MRI by allowing diffusion contrast settings to change between shots in a multi-shot EPI acquisition (i.e., intra-scan modulation). The framework estimates diffusion parameter maps directly from the acquired intra-scan modulated k-space data, while simultaneously accounting for shot-to-shot phase inconsistencies. The performance of the estimation framework is evaluated using Monte Carlo simulation studies and in-vivo experiments and compared to that of reference methods that rely on parallel imaging for shot-to-shot phase correction. Results Simulation and real-data experiments show that ADEPT yields more accurate and more precise estimates of the diffusion metrics in multi-shot EPI data in comparison with the reference methods. Conclusion ADEPT allows fast multi-shot EPI diffusion MRI without significantly degrading the accuracy and precision of the estimated diffusion maps.
引用
收藏
页码:396 / 410
页数:15
相关论文
共 50 条
  • [1] Multi-contrast echo-planar imaging sequence (Echo-planar imaging mix) in clinical situations demanding faster MRI-brain scans
    Ganesh, Viswanadh Kalaparti Sri Venkata
    Kamepalli, Hari Kishore
    Sharma, Dev Prakash
    Thomas, Bejoy
    Kesavadas, Chandrasekharan
    [J]. JOURNAL OF NEUROSCIENCES IN RURAL PRACTICE, 2024, 15 (02) : 341 - 348
  • [2] ECHO-PLANAR IMAGING OF DIFFUSION AND PERFUSION
    TURNER, R
    LEBIHAN, D
    CHESNICK, AS
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1991, 19 (02) : 247 - 253
  • [3] ECHO-PLANAR DIFFUSION SPECTROSCOPIC IMAGING
    BITO, Y
    HIRATA, S
    NABESHIMA, T
    YAMAMOTO, E
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (01) : 69 - 73
  • [4] ECHO-PLANAR IMAGING
    DELAPAZ, RL
    [J]. RADIOGRAPHICS, 1994, 14 (05) : 1045 - 1058
  • [5] Echo-Planar Imaging
    University of Nottingham, United Kingdom
    [J]. eMagRes, 2007,
  • [6] The b matrix in diffusion tensor echo-planar imaging
    Mattiello, J
    Basser, PJ
    LeBihan, D
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (02) : 292 - 300
  • [7] ECHO-PLANAR IMAGING OF PERFLUOROCARBONS
    BARKER, BR
    MASON, RP
    PESHOCK, RM
    [J]. MAGNETIC RESONANCE IMAGING, 1993, 11 (08) : 1165 - 1173
  • [8] ADVANCES IN ECHO-PLANAR IMAGING
    MANSFIELD, P
    DOYLE, M
    CHAPMAN, B
    GUILFOYLE, D
    CAWLEY, M
    COUPLAND, RE
    CHRISPIN, A
    SMALL, P
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1985, 58 (690): : 583 - 584
  • [9] Echo-planar imaging of the uterus
    Kiryu, S
    Okada, Y
    Matsuoka, Y
    Abe, O
    Ohtomo, K
    Sasaki, Y
    [J]. RADIOLOGY, 1996, 201 : 595 - 595
  • [10] Radial echo-planar imaging
    Silva, AC
    Barbier, EL
    Lowe, IJ
    Koretsky, AP
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1998, 135 (01) : 242 - 247