Reliable in vitro method for the evaluation of the primary stability and load transfer of transfemoral prostheses for osseointegrated implantation

被引:1
|
作者
Galteri, Giulia [1 ]
Palanca, Marco [1 ]
Alesi, Domenico [2 ]
Zaffagnini, Stefano [2 ]
Morellato, Kavin [3 ]
Gruppioni, Emanuele [3 ]
Cristofolini, Luca [1 ]
机构
[1] Alma Mater Studiorum Univ Bologna, Sch Engn & Architecture, Dept Ind Engn, Bologna, Italy
[2] IRCCS Ist Ortoped Rizzoli, Bologna, Italy
[3] Ctr Protesi INAIL, Bologna, Italy
关键词
lower-limb amputation; above-the-knee amputation; transfemoral osseointegrated prosthesis; primary stability; load transfer; in vitro mechanical test; micromotion; BONE-ANCHORED PROSTHESES; QUALITY-OF-LIFE; FEMORAL AMPUTATION; DIRECT FIXATION; FOLLOW-UP; AMPUTEES; STRESS; ATTACHMENT; FAILURE; STEM;
D O I
10.3389/fbioe.2024.1360208
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Osseointegrated transfemoral prostheses experience aseptic complications with an incidence between 3% and 30%. The main aseptic risks are implant loosening, adverse bone remodeling, and post-operative periprosthetic fractures. Implant loosening can either be due to a lack of initial (primary) stability of the implant, which hinders bone ingrowth and therefore prevents secondary stability, or, in the long-term, to the progressive resorption of the periprosthetic bone. Post-operative periprosthetic fractures are most often caused by stress concentrations. A method to simultaneously evaluate the primary stability and the load transfer is currently missing. Furthermore, the measurement errors are seldom reported in the literature. In this study a method to reliably quantify the bone implant interaction of osseointegrated transfemoral prostheses in terms of primary stability and load transfer was developed, and its precision was quantified. Micromotions between the prosthesis and the host bone and the strains on the cortical bone were measured on five human cadaveric femurs with a typical commercial osseointegrated implant. To detect the primary stability of the implant and the load transfer, cyclic loads were applied, simulating the peak load during gait. Digital Image Correlation was used to measure displacements and bone strains simultaneously throughout the test. Permanent migrations and inducible micromotions were measured (three translations and three rotations), while, on the same specimen, the full-field strain distribution on the bone surface was measured. The repeatability tests showed that the devised method had an intra-specimen variability smaller than 6 mu m for the translation, 0.02 degrees for the rotations, and smaller than 60 microstrain for the strain distribution. The inter-specimen variability was larger than the intra-specimen variability due to the natural differences between femurs. Altogether, the measurement uncertainties (intrinsic measurement errors, intra-specimen repeatability and inter-specimen variability) were smaller than critical levels of biomarkers for adverse remodelling and aseptic loosening, thus allowing to discriminate between stable and unstable implants, and to detect critical strain magnitudes in the host bone. In conclusion, this work showed that it is possible to measure the primary stability and the load transfer of an osseointegrated transfemoral prosthesis in a reliable way using a combination of mechanical testing and DIC.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Improved primary stability and load transfer of a customized osseointegrated transfemoral prosthesis compared to a commercial one
    Galteri, Giulia
    Betti, Valentina
    Alesi, Domenico
    Zaffagnini, Stefano
    Palanca, Marco
    Gruppioni, Emanuele
    Cristofolini, Luca
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2025, 20 (01):
  • [2] Vibrotactile evaluation: Osseointegrated versus socket-suspended transfemoral prostheses
    Haggstrom, Eva
    Hagberg, Kerstin
    Rydevik, Bjorn
    Branemark, Rickard
    JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2013, 50 (10): : 1423 - 1434
  • [3] In vitro and in silico methods for the biomechanical assessment of osseointegrated transfemoral prostheses: a systematic review
    Galteri, Giulia
    Cristofolini, Luca
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11
  • [4] Load applied on osseointegrated implant by transfemoral bone-anchored prostheses fitted with state-of-the-art prosthetic components
    Frossard, Laurent
    Laux, Stefan
    Geada, Marta
    Heym, Peter Paul
    Lechler, Knut
    CLINICAL BIOMECHANICS, 2021, 89 (89)
  • [5] A Comparative Finite-Element Analysis of Bone Failure and Load Transfer of Osseointegrated Prostheses Fixations
    Tomaszewski, P. K.
    Verdonschot, N.
    Bulstra, S. K.
    Verkerke, G. J.
    ANNALS OF BIOMEDICAL ENGINEERING, 2010, 38 (07) : 2418 - 2427
  • [6] A Comparative Finite-Element Analysis of Bone Failure and Load Transfer of Osseointegrated Prostheses Fixations
    P. K. Tomaszewski
    N. Verdonschot
    S. K. Bulstra
    G. J. Verkerke
    Annals of Biomedical Engineering, 2010, 38 : 2418 - 2427
  • [7] Towards the standardization of in vitro load transfer investigations of hip prostheses
    Cristofolini, L
    Viceconti, M
    JOURNAL OF STRAIN ANALYSIS FOR ENGINEERING DESIGN, 1999, 34 (01): : 1 - 15
  • [8] Shortening of an anatomical stem, how short is short enough? An in vitro study of load transfer and primary stability
    Ostbyhaug, Per Olav
    Klaksvik, Jomar
    Romundstad, Pal
    Aamodt, Arild
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2013, 227 (H5) : 481 - 489
  • [9] Evaluation of a method for reliable message transfer communication in CORBA
    Iida, K
    Kikuchi, J
    FIRST INTERNATIONAL ENTERPRISE DISTRIBUTED OBJECT COMPUTING WORKSHOP, PROCEEDINGS, 1997, : 104 - 110
  • [10] A METHOD FOR THE COMPARATIVE-EVALUATION OF THE INITIAL STABILITY OF CEMENTLESS HIP PROSTHESES
    EULENBERGER, J
    SCHNEIDER, E
    STEINER, W
    WYDER, D
    FRIEDMAN, R
    JOURNAL OF BIOMECHANICS, 1987, 20 (08) : 808 - 808