CO2 Joule-Thomson effect: Application on premium connections for CCS well

被引:3
|
作者
Boufflers, Laurent [1 ]
Martin, Pierre [1 ]
Mauger, Pierre [1 ]
Rodriguez, Diana [2 ]
机构
[1] Vallourec OneR&D Connect, 23 Route Leval, F-59620 Aulnoye Aymeries, France
[2] Vallourec Headquarter, 12 Rue Verrerie, F-92190 Meudon, France
来源
CARBON CAPTURE SCIENCE & TECHNOLOGY | 2024年 / 11卷
关键词
CCS; CO2; Storage; Leakage risk assessment; Safety; Joule-Thomson effect; Blow-out; Connections; Integrity; Testing methodology;
D O I
10.1016/j.ccst.2023.100185
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
CCS (Carbon Capture and Storage) is a major technology aiming to reduce greenhouse gases and reduce carbon footprint. In these applications, Oil Country Tubular Goods (OCTG) and associated premium connections are used to inject industrial CO2 into stable geological formations such as depleted oil and gas fields or saline aquifers, in liquid or dense phase to permanently store it. While current standards (API RP 5C5, ISO 13,679) allow qualification of premium connections for Oil & Gas application, no standard exists for CCS applications. In that frame, a new test methodology was developed to evaluate the impact of Joule-Thomson effect on premium connection, in the scenario of a CO2 blow-out and intermittent operation of the injection wells, such as shut-in of the subsurface safety valve (SSSV) or injection phase. To confirm that premium connections remain tight and safe after being exposed to a rapid depressurization of CO2, they have been physically tested in a horizontal load frame. The test consisted in the filling of the sample with CO2 up to a minimum of 100 bar and a temperature below 30 degrees C to ensure liquid state, or above 32 degrees C to ensure supercritical state inside the sample, and then depressurizing the sample through an orifice of 2 or 4 mm until complete drop of pressure. Minimum measured temperature on outer pipe wall reached around -50 degrees C before dry ice CO2 formation. Maximum measured gradient of temperature observed was around 70 degrees C. No leakage nor connection damages were observed during the pressure release sequences. Sealability was then confirmed during the internal pressure and external pressure test performed afterwards.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] ADIABATIC DIFFERENTIAL JOULE-THOMSON EFFECT IN NEON
    DEDIKOV, YA
    ORLOVA, MP
    MEDVEDEV, VA
    ZHURNAL FIZICHESKOI KHIMII, 1972, 46 (10): : 2669 - &
  • [42] GAS-SOLID JOULE-THOMSON EFFECT
    PIEROTTI, RA
    RYBOLT, TR
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1979, (APR): : 33 - 33
  • [43] JOULE-THOMSON EFFECT IN COMPRESSED LIQUID WATER
    POTTER, JH
    JOURNAL OF ENGINEERING FOR INDUSTRY, 1971, 93 (02): : 755 - &
  • [44] THE GAS-SOLID JOULE-THOMSON EFFECT
    PIEROTTI, RA
    RYBOLT, TR
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1983, 185 (MAR): : 39 - COLL
  • [45] The "conversion curve" of the Joule-Thomson effect for air
    Schulze, FA
    ANNALEN DER PHYSIK, 1916, 49 (05) : 585 - 593
  • [46] On the liquefaction of helium by means of the Joule-Thomson effect
    Zelmanov, JL
    COMPTES RENDUS DE L ACADEMIE DES SCIENCES DE L URSS, 1938, 20 : 537 - 538
  • [47] The Joule-Thomson effect and the interior friction of fluids
    Kosinska, M
    COMPTES RENDUS HEBDOMADAIRES DES SEANCES DE L ACADEMIE DES SCIENCES, 1928, 187 : 1037 - 1039
  • [48] Analytical model for Joule-Thomson cooling under heat exchange during CO2 storage
    Chesnokov, Christina
    Farajzadeh, Rouhi
    Prempeh, Kofi Ohemeng Kyei
    Kahrobaei, Siavash
    Snippe, Jeroen
    Bedrikovetsky, Pavel
    ADVANCES IN WATER RESOURCES, 2024, 190
  • [49] The mixing cooling effect and its possible application in mixture Joule-Thomson refrigerators
    Gong, MQ
    Wu, JF
    CRYOGENICS AND REFRIGERATION - PROCEEDINGS OF ICCR'2003, 2003, : 315 - 318
  • [50] Solid carbon dioxide from flue gas by application of Joule-Thomson effect
    Germann, FEE
    INDUSTRIAL AND ENGINEERING CHEMISTRY, 1933, 25 : 150 - 152