Comparative study of sub-second temporal resolution 4D-MRI and 4D-CT for target motion assessment in a phantom model

被引:1
|
作者
Wang, Tianyuan [1 ]
Sofue, Keitaro [2 ]
Shimada, Ryuji [3 ]
Ishihara, Takeaki [1 ]
Yada, Ryuichi [1 ]
Miyamoto, Masanori [3 ]
Sasaki, Ryohei [1 ]
Murakami, Takamichi [2 ]
机构
[1] Kobe Univ Hosp, Dept Radiat Oncol, Kobe, Japan
[2] Kobe Univ, Grad Sch Med, Dept Radiol, 7-5-2 Kusunoki Cho,Chuo Ku, Kobe 6500017, Japan
[3] Kobe Univ Hosp, Ctr Radiol & Radiat Oncol, Kobe, Japan
基金
日本学术振兴会;
关键词
GD-EOB-DTPA; RESPIRATORY MOTION; HEPATOCELLULAR-CARCINOMA; RADIATION-THERAPY; LIVER-TUMORS; LESION SIZE; MRI; RADIOTHERAPY; CT; RECONSTRUCTION;
D O I
10.1038/s41598-023-42773-z
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
To develop and investigate the feasibility of sub-second temporal resolution volumetric T1-weighted four-dimensional (4D-) MRI in comparison with 4D-CT for respiratory-correlated motion assessment using an MRI/CT-compatible phantom. Sub-second high temporal resolution (0.5 s) gradient-echo T1-weighted 4D-MRI was developed using a volumetric acquisition scheme with compressed sensing. An MRI/CT-compatible motion phantom (simulated liver tumor) with three sinusoidal movements of amplitudes and two respiratory patterns was introduced and imaged with 4D-MRI and 4D-CT to investigate the geometric accuracy of the target movement. The geometric accuracy, including centroid position, volume, similarity index of dice similarity coefficient (DSC), and Hausdorff distance (HD), was systematically evaluated. Proposed 4D-MRI achieved a similar geometric accuracy compared with 4D-CT regarding the centroid position, volume, and similarity index. The observed position differences of the absolute average centroid were within 0.08 cm in 4D-MRI and 0.03 cm in 4D-CT, less than the 1-pixel resolution for each modality. The observed volume difference in 4D-MRI/4D-CT was within 0.73 cm3 (4.5%)/0.29 cm3 (2.1%) for a large target and 0.06 cm3 (11.3%)/0.04 cm3 (11.6%) for a small target. The observed DSC values for 4D-MRI/4D-CT were at least 0.93/0.95 for the large target and 0.83/0.84 for the small target. The maximum HD values were 0.25 cm/0.31 cm for the large target and 0.21 cm/0.15 cm for the small target. Although 4D-CT potentially exhibit superior numerical accuracy in phantom studies, the proposed high temporal resolution 4D-MRI demonstrates sub-millimetre geometric accuracy comparable to that of 4D-CT. These findings suggest that the 4D-MRI technique is a viable option for characterizing motion and generating phase-dependent internal target volumes within the realm of radiotherapy.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Study on Liver Cancer Target Volume Variations between 4D-CT and 3D-CT Associated with Active Breathing Control Device
    Chen, J.
    Yin, Y.
    Gong, G.
    MEDICAL PHYSICS, 2011, 38 (06) : 3466 - +
  • [42] Study on Liver Cancer Target Volume Variations Between 4D-CT and 3D-CT Associated With Active Breathing Control Device
    Chen, J.
    Gong, G.
    Yin, Y.
    EUROPEAN JOURNAL OF CANCER, 2011, 47 : S190 - S191
  • [43] Evaluation of target volume and dose accuracy in intrafractional cases of lung cancer based on 4D-CT and 4D-CBCT images using an in-house dynamic thorax phantom
    Haqqi, Firyal Dhiyaul
    Sudarmaji, Arief
    Wibowo, Wahyu Edy
    Nasution, Nuruddin
    Handoko, Handoko
    Fauzia, Annisa Rahma
    Qudsi, Jihadil
    Pawiro, Supriyanto Ardjo
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2022, 27 (02) : 360 - 370
  • [44] A pilot study of respiratory motion characterization in the abdomen using a fast volumetric 4D-MRI for MR-guided radiotherapy
    Wong, Oi Lei
    Law, Max Wai Kong
    Poon, Darren Ming Chun
    Yung, Raymond Wai Hung
    Yu, Siu ki
    Cheung, Kin yin
    Yuan, Jing
    PRECISION RADIATION ONCOLOGY, 2022, 6 (02): : 100 - 109
  • [45] Simulation and evaluation of free breathing planning target volumes in the lung in the presence of respiratory tumor motion using 4D-CT data
    Mechalakos, J
    Pevsner, A
    Yorke, E
    Mageras, G
    Rosenzweig, K
    Nemeh, S
    Humm, J
    Larson, S
    Ling, C
    MEDICAL PHYSICS, 2004, 31 (06) : 1716 - 1716
  • [46] Low dose 4D-CT super-resolution reconstruction via inter-plane motion estimation based on optical flow
    Liu, Hui
    Lin, Yuxiu
    Ibragimov, Bulat
    Zhang, Caiming
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2020, 62
  • [47] Feasibility of capturing vessel expansion with 4D-CTA: Phantom study to determine reproducibility, spatial and temporal resolution
    Linden, Sabine M. L.
    Stam, Lotte B.
    Aquarius, Rene
    Hering, Alessa
    de Korte, Chris L.
    Prokop, Mathias
    Boogaarts, Hieronymus D.
    Meijer, Frederick J. A.
    Oostveen, Luuk J.
    MEDICAL PHYSICS, 2024, 51 (10) : 7171 - 7179
  • [48] Combined effects of respiratory motion and object size on 3-D and 4-D PET/CT images: Dynamic phantom study
    Park, S.
    Ionascu, D.
    Killoran, J.
    Mamede, M.
    Thomas, S.
    Gerbaudo, V.
    Chin, L.
    Berbeco, R.
    MEDICAL PHYSICS, 2007, 34 (06) : 2571 - 2571
  • [49] Q.Freeze for Respiratory Motion Correction in PET/CT: Assessment and Optimisation with a 4D PET/CT phantom and patient data
    Havariyoun, G.
    Kalogianni, E.
    Ruiz, D.
    Corcoran, B.
    Mulholland, N.
    Vivian, G.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S392 - S392
  • [50] Motion-Induced Object Distortion Using MR-Linac and 4D CT: A Phantom Study
    Yang, W.
    Lee, H.
    Kadbi, M.
    Ding, Y.
    Ibbott, G.
    MEDICAL PHYSICS, 2018, 45 (06) : E231 - E231