Comparative study of sub-second temporal resolution 4D-MRI and 4D-CT for target motion assessment in a phantom model

被引:1
|
作者
Wang, Tianyuan [1 ]
Sofue, Keitaro [2 ]
Shimada, Ryuji [3 ]
Ishihara, Takeaki [1 ]
Yada, Ryuichi [1 ]
Miyamoto, Masanori [3 ]
Sasaki, Ryohei [1 ]
Murakami, Takamichi [2 ]
机构
[1] Kobe Univ Hosp, Dept Radiat Oncol, Kobe, Japan
[2] Kobe Univ, Grad Sch Med, Dept Radiol, 7-5-2 Kusunoki Cho,Chuo Ku, Kobe 6500017, Japan
[3] Kobe Univ Hosp, Ctr Radiol & Radiat Oncol, Kobe, Japan
基金
日本学术振兴会;
关键词
GD-EOB-DTPA; RESPIRATORY MOTION; HEPATOCELLULAR-CARCINOMA; RADIATION-THERAPY; LIVER-TUMORS; LESION SIZE; MRI; RADIOTHERAPY; CT; RECONSTRUCTION;
D O I
10.1038/s41598-023-42773-z
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
To develop and investigate the feasibility of sub-second temporal resolution volumetric T1-weighted four-dimensional (4D-) MRI in comparison with 4D-CT for respiratory-correlated motion assessment using an MRI/CT-compatible phantom. Sub-second high temporal resolution (0.5 s) gradient-echo T1-weighted 4D-MRI was developed using a volumetric acquisition scheme with compressed sensing. An MRI/CT-compatible motion phantom (simulated liver tumor) with three sinusoidal movements of amplitudes and two respiratory patterns was introduced and imaged with 4D-MRI and 4D-CT to investigate the geometric accuracy of the target movement. The geometric accuracy, including centroid position, volume, similarity index of dice similarity coefficient (DSC), and Hausdorff distance (HD), was systematically evaluated. Proposed 4D-MRI achieved a similar geometric accuracy compared with 4D-CT regarding the centroid position, volume, and similarity index. The observed position differences of the absolute average centroid were within 0.08 cm in 4D-MRI and 0.03 cm in 4D-CT, less than the 1-pixel resolution for each modality. The observed volume difference in 4D-MRI/4D-CT was within 0.73 cm3 (4.5%)/0.29 cm3 (2.1%) for a large target and 0.06 cm3 (11.3%)/0.04 cm3 (11.6%) for a small target. The observed DSC values for 4D-MRI/4D-CT were at least 0.93/0.95 for the large target and 0.83/0.84 for the small target. The maximum HD values were 0.25 cm/0.31 cm for the large target and 0.21 cm/0.15 cm for the small target. Although 4D-CT potentially exhibit superior numerical accuracy in phantom studies, the proposed high temporal resolution 4D-MRI demonstrates sub-millimetre geometric accuracy comparable to that of 4D-CT. These findings suggest that the 4D-MRI technique is a viable option for characterizing motion and generating phase-dependent internal target volumes within the realm of radiotherapy.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Comparative study of sub-second temporal resolution 4D-MRI and 4D-CT for target motion assessment in a phantom model
    Tianyuan Wang
    Keitaro Sofue
    Ryuji Shimada
    Takeaki Ishihara
    Ryuichi Yada
    Masanori Miyamoto
    Ryohei Sasaki
    Takamichi Murakami
    Scientific Reports, 13
  • [2] Sub-Second Temporal Resolution 4D-MRI and 4D-CT for Target Motion Assessment in a Phantom Model
    Wang, T.
    Sofue, K.
    Shimada, R.
    Ishihara, T.
    Yada, R.
    Sasaki, R.
    Murakami, T.
    MEDICAL PHYSICS, 2024, 51 (09) : 6584 - 6585
  • [3] Breathing pattern analysis of 4D-CT and 4D-MRI
    Higuchi, Satomi
    Goodwin, Jonathan
    OConnor, Laura
    Zerafa, Amy
    Greer, Peter
    Ludbrook, Jane
    Simpson, John
    ASIA-PACIFIC JOURNAL OF CLINICAL ONCOLOGY, 2021, 17 : 24 - 24
  • [4] Geometric Validation of K-Space Self-Gated 4D-MRI Vs. 4D-CT Using A Respiratory Motion Phantom
    Yue, Y.
    Fan, Z.
    Yang, W.
    Pang, J.
    McKenzie, E.
    Deng, Z.
    Tuli, R.
    Sandler, H.
    Li, D.
    Fraass, B.
    MEDICAL PHYSICS, 2014, 41 (06) : 572 - 573
  • [5] Geometric validation of self-gating k-space-sorted 4D-MRI vs 4D-CT using a respiratory motion phantom
    Yue, Yong
    Fan, Zhaoyang
    Yang, Wensha
    Pang, Jianing
    Deng, Zixin
    McKenzie, Elizabeth
    Tuli, Richard
    Wallace, Robert
    Li, Debiao
    Fraass, Benedick
    MEDICAL PHYSICS, 2015, 42 (10) : 5787 - 5797
  • [6] Comparison of surrogate tumour trajectories derived from 4D-CT and 4D-MRI
    Remmert, G.
    Biederer, J.
    Fabel, M.
    Dinkel, J.
    Lohberger, F.
    Moser, T.
    Hartman, G.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S164 - S164
  • [7] A fast volumetric 4D-MRI with sub-second frame rate for abdominal motion monitoring and characterization in MRI-guided radiotherapy
    Yuan, Jing
    Wong, Oi Lei
    Zhou, Yiliang
    Chueng, Kin Yin
    Yu, Siu Ki
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2019, 9 (07) : 1303 - 1314
  • [8] COMPARISON OF 4D-PET / 4D-CT / 4D-MRI TREATMENT PLANNING FOR RADIOTHERAPY OF LUNG CANCER
    Hoinkis, C.
    Appold, S.
    Enghardt, W.
    Abolmaali, N.
    Reiffenstuhl, C.
    Richter, C.
    Zips, D.
    Zoephel, K.
    Kotzerke, J.
    Baumann, M.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S163 - S163
  • [9] Laboratory based study of dynamical processes by 4D X-ray CT with sub-second temporal resolution
    Vavrik, D.
    Jakubek, J.
    Kumpova, I.
    Pichotka, M.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [10] Assessment of 4D-MRI for Robust Motion and Volume Characterization
    Glide-Hurst, C.
    Kim, J.
    Hu, Y.
    Wen, N.
    Mutic, S.
    Chetty, I.
    MEDICAL PHYSICS, 2014, 41 (06) : 539 - 539