Radiation exposure in cone beam CT measured using a MOSFET and RPLGD dosimeter and Monte Carlo simulation in phantom

被引:0
|
作者
Kweon, Dae Cheol [1 ]
机构
[1] Shinhan Univ, Dept Radiol Sci, Uijongbu, South Korea
关键词
Absorbed dose; cone beam CT; radiation dose; MOSFET; RPLGD; PANORAMIC RADIOGRAPHY; IMAGE QUALITY; TOMOGRAPHY; ORGAN; VALIDATION;
D O I
10.3233/XST-230026
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
BACKGROUND: Due to the wide application of the cone beam computed tomography (CBCT) in clinical practice, it is important to assess radiation dose of CBCT more accurately and efficiently in different clinical applications. OBJECTIVE: This study aims to calculate effective and absorbed doses in CBCT measured in an anthropomorphic phantom using computer-based Monte Carlo (PCXMC) software, and to conduct comparative evaluations of MOSFET (metal-oxide-semiconductor field-effect transistor) and radiophotoluminescence glass dosimeters (RPLGD). METHODS: Effective and absorbed organ doses are compared with those obtained using MOSFET and RPLGD dosimetry in an anthropomorphic phantom given the same exposure settings. Effective and absorbed organ doses from CBCT during scout and main projections are calculated using PCXMC and PCXMCRotation software, respectively. RESULTS: The mean effective dose from CBCT calculated using PCXMC software is 233.8 mu Sv, while the doses calculated using dosimetry (MOSFET and RPLGD) are 266.67 mu Sv and 268.78 mu Sv, respectively. The X-ray source variation is 0.79%. The prescription limits based on the Friedman test for MOSFET and RPLGD pre-points (i.e., in an analytical analysis of diagnostic names in CBCT) are not statistically significant. The calculated correlation coefficient between MOSFET- and RPLGD-derived absorbed dose values with respect to a field of view CBCT parameter of 17x13.5mm is r = 0.8623. CONCLUSIONS: The study demonstrates that the PCXMC software may be used as an alternative to MOSFET and RPLGD dosimetry for effective and absorbed organ dose estimation in CBCT conducted with a large FOV in an anthropomorphic phantom.
引用
收藏
页码:837 / 852
页数:16
相关论文
共 50 条
  • [1] Imaging and Radiation Therapy: GATE Monte Carlo Simulation of a Megavolt Cone Beam CT
    Benhalouche, S.
    Bert, J.
    Autret, A.
    Visvikis, D.
    Pradier, O.
    Boussion, N.
    [J]. 2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [2] Monte Carlo simulation of a cone-beam CT system for lightweight casts
    Thuy Duong Tran
    Ngoc Ha Bui
    Kim Tuan Tran
    Ngoc Toan Tran
    [J]. RADIATION DETECTION TECHNOLOGY AND METHODS, 2021, 5 (04) : 504 - 512
  • [3] Monte Carlo simulation of a cone-beam CT system for lightweight casts
    Thuy Duong Tran
    Ngoc Ha Bui
    Kim Tuan Tran
    Ngoc Toan Tran
    [J]. Radiation Detection Technology and Methods, 2021, 5 : 504 - 512
  • [4] Monte Carlo simulation of MOSFET dosimeter for electron backscatter using the GEANT4 code
    Chow, James C. L.
    Leung, Michael K. K.
    [J]. MEDICAL PHYSICS, 2008, 35 (06) : 2383 - 2390
  • [5] Monte Carlo Simulation of Elekta XVI Cone Beam System and Dose Distribution in CTDI Phantom
    Feng, W.
    Deng, J.
    Chi, Y.
    Drake, D.
    Bakalyar, D.
    Yan, D.
    [J]. MEDICAL PHYSICS, 2008, 35 (06) : 2709 - +
  • [6] Multi-Slice CT Versus Cone Beam CT for Breast Imaging: Radiation Dose Distributions with Monte Carlo Simulation
    Yi, Y.
    Han, T.
    Liu, X.
    Shen, Y.
    Chen, L.
    Zhong, Y.
    Lai, C.
    Ge, S.
    You, Z.
    Wang, T.
    Shaw, C.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)
  • [7] Radiation Exposure of Patients by Cone Beam CT during Endobronchial Navigation - A Phantom Study
    Hohenforst-Schmidt, Wolfgang
    Banckwitz, Rosemarie
    Zarogoulidis, Paul
    Vogl, Thomas
    Darwiche, Kaid
    Goldberg, Eugene
    Huang, Haidong
    Simoff, Michael
    Li, Qiang
    Browning, Robert
    Freitag, Lutz
    Turner, J. Francis
    Le Pivert, Patrick
    Yarmus, Lonny
    Zarogoulidis, Konstantinos
    Brachmann, Johannes
    [J]. JOURNAL OF CANCER, 2014, 5 (03): : 192 - 202
  • [8] Patient Dose from the Elekta XVI Cone-beam CT: Phantom and Monte Carlo Study
    Jarvis, R.
    Downes, P.
    Radu, E.
    Spezi, E.
    [J]. CLINICAL ONCOLOGY, 2009, 21 (03) : 270 - 270
  • [9] Dynamic Bowtie Filter Design with Monte Carlo Simulation for Cone-Beam CT
    Zhu, Huijie
    Gao, Fuqiang
    Wu, Weiwen
    Liu, Fenglin
    [J]. 2017 29TH CHINESE CONTROL AND DECISION CONFERENCE (CCDC), 2017, : 3160 - 3165
  • [10] Validation of a Monte Carlo simulation for dose assessment in dental cone beam CT examinations
    Morant, J. J.
    Salvado, M.
    Casanovas, R.
    Hernandez-Giron, I.
    Velasco, E.
    Calzado, A.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2012, 28 (03): : 200 - 209