Application of Carbon Paste Electrodes Modified with Imprinted Zeolite X as Potentiometric Sensors for Amitriptyline Analysis in Pharmaceuticals

被引:0
|
作者
Khasanah, Miratul [1 ]
Widati, Alfa Akustia [1 ]
Wahyuni, Ade Sukma [1 ]
Bureni, Dedy Samuel [1 ]
机构
[1] Univ Airlangga, Fac Sci & Technol, Chem Dept, Surabaya 60115, Indonesia
来源
关键词
Amitriptyline analysis; Potentiometry; Carbon paste electrode; Imprinted zeolite X; Amitriptyline selectivity; Affordable medicine;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Carbon paste electrodes have been developed to improve the performance and selectivity of electrodes for the potentiometric analysis of amitriptyline (AMT). Carbon paste electrodes modified with imprinted zeolites (IZ) were developed as potentiometric sensors for AMT analysis. In this study, zeolite X was synthesized using Na2O, Al2O3, SiO2, and H2O at a mole ratio of 4.5:1:3:315. The IZ was synthesized by adding AMT to the mixture at an AMT/Si molar ratio of 0.0306 as a template. Subsequently, AMT was extracted from the zeolite framework to form active and selective AMT recognition sites. The optimum performance was achieved by the electrode composed of activated carbon, paraffin, and IZ at a composition of 12:7:1, which was expressed by a Nernst factor of 28.38 mV decade(-1), measurement range of 10(-5)-10(-2) M with a correlation coefficient of 0.9994, and a low detection limit of 1.15 x 10(-5) M. The detection limit can accommodate the lower dose of AMT in pharmaceuticals. The modified electrode had a precision of 98.3-99.7% and an accuracy of 91.2-107%, with a response time of 24-211 s. Moreover, it was stable within four weeks after 70 uses. Application of the modified electrode in the determination of AMT in three pharmaceutical samples resulted in a 96-102% recovery. The presence of glucose, lactose, mannitol, and ZnSO4 had no effect on the potentiometric analysis of AMT using the modified electrode. The excellent analytical performance of the modified carbon paste electrode suggests its potential applications in the analysis of AMT, an affordable medicine.
引用
收藏
页码:339 / 352
页数:14
相关论文
共 50 条
  • [41] Perfluorosulfonic Acid Membranes with Functionalized Carbon Nanotubes in Potentiometric Sensors for the Analysis of Nicotinic Acid Pharmaceuticals
    A. V. Parshina
    E. Yu. Safronova
    T. S. Kolganova
    G. Z. Habtemariam
    O. V. Bobreshova
    Journal of Analytical Chemistry, 2022, 77 : 195 - 205
  • [42] Cyclodextrin modified carbon paste based electrodes as sensors for the determination of carcinogenic polycyclic aromatic amines
    Ferancová, A
    Korgová, E
    Labuda, J
    Zima, J
    Barek, J
    ELECTROANALYSIS, 2002, 14 (23) : 1668 - 1673
  • [43] Chemical Modified Carbon Paste Electrode for Potentiometric Determination of Mo(VI) and its Application in Food Analysis and Agriculture Fertilizers
    EL-Sanafery, Safa S.
    Abass, Ashraf A.
    Mohamed, Gehad G.
    ELECTROANALYSIS, 2022, 34 (05) : 872 - 882
  • [44] Chemically modified carbon paste electrode for potentiometric analysis of Cyproheptadine hydrochloride in serum and urine
    Abu-Shawish, Hazem M.
    Saadeh, Salman M.
    CANADIAN JOURNAL OF ANALYTICAL SCIENCES AND SPECTROSCOPY, 2007, 52 (04): : 225 - 232
  • [45] Carbon paste electrodes modified with a new phenothiazine derivative adsorbed on zeolite and on mineral clay for NADH oxidation
    Gligor, Delia
    Balaj, Florina
    Maicaneanu, Andrada
    Gropeanu, R.
    Grosu, I.
    Muresan, Liana
    Popescu, I. C.
    MATERIALS CHEMISTRY AND PHYSICS, 2009, 113 (01) : 283 - 289
  • [46] Prussian blue modified carbon nanotube paste electrodes: A comparative study and a biochemical application
    Ricci, F
    Amine, A
    Moscone, D
    Palleschi, G
    ANALYTICAL LETTERS, 2003, 36 (09) : 1921 - 1938
  • [47] APPLICATIONS IN DRUG ANALYSIS OF CARBON PASTE ELECTRODES MODIFIED BY FATTY-ACIDS
    KHODARI, M
    KAUFFMANN, JM
    PATRIARCHE, GJ
    GHANDOUR, MA
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1989, 7 (12) : 1491 - 1497
  • [48] Use of carbon-paste electrodes modified with macrocyclic compounds in voltammetric analysis
    Shajdarova, L.G.
    Ulakhovich, N.A.
    Al'-Gakhri, M.A.
    Budnikov, G.K.
    Glebov, A.N.
    Zhurnal Analiticheskoi Khimii, 50 (07): : 755 - 760
  • [49] Modified carbon-paste electrodes as sensors for the determination of 1,4-benzodiazepines:: Application to the determination of diazepam and oxazepam in biological fluids
    Lozano-Chaves, M. Elisa
    Palacios-Santander, J. M.
    Cubillana-Aguilera, L. M.
    Naranjo-Rodriguez, I.
    Hidalgo-Hidalgo-de-Cisneros, J. L.
    SENSORS AND ACTUATORS B-CHEMICAL, 2006, 115 (02) : 575 - 583
  • [50] RETRACTION: Development of electrode carbon paste modified by molecularly imprinted polymer as sensor for analysis of creatinine by potentiometric (Retraction of Vol 19, Pg 1808, 2017)
    Khasanah, Miratul
    Darmokoesoemo, Handoko
    Sari, Nunung Mareta
    Kadmi, Yassine
    Elmsellem, Hicham
    Kusuma, Heri Septya
    RESULTS IN PHYSICS, 2020, 19