Application of Carbon Paste Electrodes Modified with Imprinted Zeolite X as Potentiometric Sensors for Amitriptyline Analysis in Pharmaceuticals

被引:0
|
作者
Khasanah, Miratul [1 ]
Widati, Alfa Akustia [1 ]
Wahyuni, Ade Sukma [1 ]
Bureni, Dedy Samuel [1 ]
机构
[1] Univ Airlangga, Fac Sci & Technol, Chem Dept, Surabaya 60115, Indonesia
来源
关键词
Amitriptyline analysis; Potentiometry; Carbon paste electrode; Imprinted zeolite X; Amitriptyline selectivity; Affordable medicine;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Carbon paste electrodes have been developed to improve the performance and selectivity of electrodes for the potentiometric analysis of amitriptyline (AMT). Carbon paste electrodes modified with imprinted zeolites (IZ) were developed as potentiometric sensors for AMT analysis. In this study, zeolite X was synthesized using Na2O, Al2O3, SiO2, and H2O at a mole ratio of 4.5:1:3:315. The IZ was synthesized by adding AMT to the mixture at an AMT/Si molar ratio of 0.0306 as a template. Subsequently, AMT was extracted from the zeolite framework to form active and selective AMT recognition sites. The optimum performance was achieved by the electrode composed of activated carbon, paraffin, and IZ at a composition of 12:7:1, which was expressed by a Nernst factor of 28.38 mV decade(-1), measurement range of 10(-5)-10(-2) M with a correlation coefficient of 0.9994, and a low detection limit of 1.15 x 10(-5) M. The detection limit can accommodate the lower dose of AMT in pharmaceuticals. The modified electrode had a precision of 98.3-99.7% and an accuracy of 91.2-107%, with a response time of 24-211 s. Moreover, it was stable within four weeks after 70 uses. Application of the modified electrode in the determination of AMT in three pharmaceutical samples resulted in a 96-102% recovery. The presence of glucose, lactose, mannitol, and ZnSO4 had no effect on the potentiometric analysis of AMT using the modified electrode. The excellent analytical performance of the modified carbon paste electrode suggests its potential applications in the analysis of AMT, an affordable medicine.
引用
收藏
页码:339 / 352
页数:14
相关论文
共 50 条
  • [31] Fabrication of Carbon Paste Electrodes Modified with Multi-walled Carbon Nanotubes for the Potentiometric Determination of Chromium(III)
    Fakhrabad, Azam Hosseini
    Khoshnood, Razieh Sanavi
    Ebrahimi, Mahmoud
    Abedi, Mohammad Reza
    JOURNAL OF ANALYTICAL CHEMISTRY, 2020, 75 (07) : 951 - 957
  • [32] Fabrication of Carbon Paste Electrodes Modified with Multi-walled Carbon Nanotubes for the Potentiometric Determination of Chromium(III)
    Razieh Sanavi Azam Hosseini Fakhrabad
    Mahmoud Khoshnood
    Mohammad Reza Ebrahimi
    Journal of Analytical Chemistry, 2020, 75 : 951 - 957
  • [33] PHENYLENEDIAMINE-CONTAINING CHEMICALLY MODIFIED CARBON PASTE ELECTRODES AS CATALYTIC VOLTAMMETRIC SENSORS
    RAVICHANDRAN, K
    BALDWIN, RP
    ANALYTICAL CHEMISTRY, 1983, 55 (09) : 1586 - 1591
  • [34] ALDOSE DEHYDROGENASE-MODIFIED CARBON-PASTE ELECTRODES AS AMPEROMETRIC ALDOSE SENSORS
    SMOLANDER, M
    MARKOVARGA, G
    GORTON, L
    ANALYTICA CHIMICA ACTA, 1995, 302 (2-3) : 233 - 240
  • [35] Voltammetric determination of riboflavin based on electrocatalytic oxidation at zeolite-modified carbon paste electrodes
    Nezamzadeh-Ejhieh, Alireza
    Pouladsaz, Pouya
    JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY, 2014, 20 (04) : 2146 - 2152
  • [36] A novel potentiometric approach for the sensitive detection of cadmium in real samples using modified carbon paste electrodes
    EL-Sanafery, Safa S. S.
    Ibrahim, Mahmoud W. W.
    Abbas, Ashraf A. A.
    Mohamed, Gehad G. G.
    ELECTROANALYSIS, 2023, 35 (11)
  • [37] Characterization of iron-modified carbon paste electrodes and their application in As(V) detection
    Eduardo Toral-Sanchez
    J. Rene Rangel-Mendez
    Luis F. Chazaro-Ruiz
    Journal of Applied Electrochemistry, 2016, 46 : 205 - 215
  • [38] Characterization of iron-modified carbon paste electrodes and their application in As(V) detection
    Toral-Sanchez, Eduardo
    Rene Rangel-Mendez, J.
    Chazaro-Ruiz, Luis F.
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2016, 46 (02) : 205 - 215
  • [39] Application of a new potentiometric method for determination of phosphate based on a surfactant-modified zeolite carbon-paste electrode (SMZ-CPE)
    Ejhieh, Alireza Nezamadeh
    Masoudipour, Neda
    ANALYTICA CHIMICA ACTA, 2010, 658 (01) : 68 - 74
  • [40] Perfluorosulfonic Acid Membranes with Functionalized Carbon Nanotubes in Potentiometric Sensors for the Analysis of Nicotinic Acid Pharmaceuticals
    Parshina, A., V
    Safronova, E. Yu
    Kolganova, T. S.
    Habtemariam, G. Z.
    Bobreshova, O., V
    JOURNAL OF ANALYTICAL CHEMISTRY, 2022, 77 (02) : 195 - 205