Vancouver type B2 periprosthetic femoral fractures: clinical and radiological outcomes from a tertiary care center

被引:1
|
作者
Tornago, Stefano [1 ]
Cavagnaro, Luca [1 ]
Mosconi, Lorenzo [1 ]
Chiarlone, Francesco [2 ]
Zanirato, Andrea [3 ,5 ]
Patroniti, Nicolo [4 ,5 ]
Formica, Matteo [3 ,5 ]
机构
[1] Osped Santa Corona, Joint Replacement Unit, Ortopedia & Traumatol 2, Viale 25 Aprile 38, I-17027 Pietra Ligure, SV, Italy
[2] Ist Clin San Rocco Grp San Donato, UO Sez Ortopedia & Traumatol 1, Via Sabbioni 24, I-25050 Ome, BS, Italy
[3] Policlin San Martino, Clin Ortoped, Largo Rosanna Benzi 10, I-16132 Genoa, GE, Italy
[4] Osped Santa Corona, Anesthesia & Intens Care Unit, Viale 25 Aprile,38, I-17027 Pietra Ligure, SV, Italy
[5] DISC, Dipartimento Sci Chirurg & Diagnost Integrate, Viale Benedetto XV 6, I-16132 Genoa, GE, Italy
关键词
Periprosthetic fracture; Total hip arthroplasty; Hip revision; Surgical technique; Outcomes; TOTAL HIP-ARTHROPLASTY; INTERNAL-FIXATION; CLASSIFICATION; MORTALITY; MANAGEMENT; FEMUR;
D O I
10.1007/s00402-023-04955-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
IntroductionThe purpose of this study was to report mid-term clinical and radiographic results after hip arthroplasty revision in Vancouver type B2 femoral periprosthetic fractures (PPFx). Specifical focus of the paper is as follows: (1) the description of a standardized and reproducible surgical technique, (2) functional outcomes presentation and (3) type and number of complications and implants' survival rate analysis.MethodsWe retrospectively reviewed all patients treated for hip revision with non-modular tapered fluted titanium stem in patients with Vancouver type B2 femur PPFx at a single institution. At least 18 months' follow-up period was required. Harris Hip Scores and SF-12 were obtained, and radiographical follow-up was performed. Complications were reported and analyzed.ResultsThe authors included 114 patients (114 hips) with a mean follow-up of 62.8 & PLUSMN; 30.6 months. All patients were treated with Wagner SL revision hip stem (Zimmer-Biomet), metal cerclage wires & PLUSMN; trochanteric plate. The mean HHS and SF-12 score at the last follow-up evaluation were respectively 81.3 & PLUSMN; 9.7 and 32.5 & PLUSMN; 7.6. Seventeen (14.9%) complications occurred. We observed five cases of dislocations, two of periprosthetic joint infections and six cases of new PPFx. The stem-related revision rate for any cause at the final FU was 1.7%, due to PJI. No patients underwent stem revision surgery for aseptic loosening. Fracture healed in all the included patients with a union-rate of 100%. The re-operation rate for any cause was 9.6%, with an implant survival rate for overall failure of 96.5%.ConclusionThe presented standard and reproducible surgical technique obtains optimal clinical and radiological results with limited complication rate at mid-term follow up. Preoperative planning as well as careful intraoperative surgical technique is of a paramount importance.
引用
收藏
页码:6919 / 6926
页数:8
相关论文
共 50 条
  • [31] Femoral offset restoration affects the early outcome of revision in patients with periprosthetic femoral fractures of Vancouver B2 - a single-center retrospective cohort study
    Lei Sun
    Wenjing Song
    Zhongyuan Zhang
    Ziyao Xu
    Mengshuai Sun
    Guangling Gao
    Hongjiang Jiang
    Changjun Ju
    BMC Musculoskeletal Disorders, 24
  • [32] Diagnosis of Vancouver type B2 periprosthetic femoral fractures should be combined with preoperative radiographs and the actual situation during surgery Reply
    Wang, Qiuru
    Li, Donghai
    Kang, Pengde
    JOURNAL OF ORTHOPAEDIC SURGERY, 2019, 27 (03)
  • [33] Radiologic outcomes of open reduction and internal fixation for cementless stems in Vancouver B2 periprosthetic fractures
    Park, Jong-Seok
    Hong, Sijohn
    Nho, Jae-Hwi
    Kang, Deokwon
    Choi, Hyung-Suk
    Suh, You-Sung
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2019, 53 (01) : 24 - 29
  • [34] Management of Vancouver type B2 and B3 femoral periprosthetic fractures using an uncemented extensively porous-coated long femoral stem prosthesis
    Canbora K.
    Kose O.
    Polat A.
    Aykanat F.
    Gorgec M.
    European Journal of Orthopaedic Surgery & Traumatology, 2013, 23 (5) : 545 - 552
  • [35] Vancouver type B2 and B3 periprosthetic fractures treated with revision total hip arthroplasty
    Amenabar, Tomas
    Rahman, Wael A.
    Avhad, Vineet V.
    Vera, Ramiro
    Gross, Allan E.
    Kuzyk, Paul R.
    INTERNATIONAL ORTHOPAEDICS, 2015, 39 (10) : 1927 - 1932
  • [36] Vancouver type B2 and B3 periprosthetic fractures treated with revision total hip arthroplasty
    Tomas Amenabar
    Wael A. Rahman
    Vineet V. Avhad
    Ramiro Vera
    Allan E. Gross
    Paul R. Kuzyk
    International Orthopaedics, 2015, 39 : 1927 - 1932
  • [37] The use of uncemented extensively porous-coated femoral components in the management of Vancouver B2 and B3 periprosthetic femoral fractures
    O'Shea, K
    Quinlan, JF
    Kutty, S
    Mulcahy, D
    Brady, OH
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (12): : 1617 - 1621
  • [38] Shape memory embracing fixator for Vancouver type B and type C periprosthetic femoral fractures
    Xiong, Yan
    Du, Quanyin
    Wang, Ziming
    Wang, Aimin
    ACTA ORTHOPAEDICA BELGICA, 2014, 80 (03): : 365 - 371
  • [39] Management of Vancouver B2 and B3 femoral periprosthetic fractures using a modular cementless stem without allografting
    Daniel Neumann
    Christoph Thaler
    Ulrich Dorn
    International Orthopaedics, 2012, 36 : 1045 - 1050
  • [40] Midterm results and complications rates in vancouver type B2 and B3 periprosthetic femoral fractures treated with modular fluted tapered stems
    Santiago, L. Iglesias
    Gerardo, Aguirre
    Fernando, Vanoli
    Leonel, Perez Alamino
    Ignacio, Pioli
    Pablo, Maletti
    Fernando, A. Lopreite
    Hernan, Del Sel
    Bartolome, L. Allende
    JOURNAL OF ORTHOPAEDICS, 2021, 28 : 1 - 4