Influence of impulse corona discharge on discharge time lag of a surge arrester with a spark gap

被引:0
|
作者
Sakoda, Tatsuyta [1 ]
Kubo, Katsutaka [2 ]
Mizutani, Manabu [2 ]
Chiba, Tomoki [2 ]
Kasuga, Yasunori [2 ]
Fukano, Takato [2 ]
机构
[1] Univ Miyazaki, Miyazaki, Japan
[2] Toshiba Energy Syst & Solut Corp, Kawasaki 2100862, Japan
关键词
Arrester; Spark gap; Discharge time lag; Impulse corona discharge; Triple junction point; PERFORMANCE; AIR;
D O I
10.1016/j.elstat.2022.103783
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
ZnO surge arrester with a spark gap is used for reducing electrical failures in power distribution systems of Japan. The high responsiveness, the low residual voltage, and the stable operating voltage are required for the arresters. However, the discharge time lag generally occurs in a spark gap. In this study, measurements of V -t characteristics and observations of optical emissions from impulse corona discharges generated at a newly designed small step edge on an inclined plane of each electrode were carried out. The small step edge made the discharge time lag and the standard deviation small. Based on the results, we indicated that the impulse corona discharge improves the discharge time lag of the sparkover.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] INFLUENCE OF CORONA DISCHARGE ON PARAFFIN COMBUSTION
    Nedybaliuk, O. A.
    Fedirchyk, I. I.
    Chernyak, V. Ya.
    PROBLEMS OF ATOMIC SCIENCE AND TECHNOLOGY, 2018, (06): : 218 - 221
  • [42] Effect of discharge parameters and control of spark breakdown in degradation of phenol by pulsed streamer corona discharge
    Shen, Yongjun
    Zhou, Minghua
    Lei, Lecheng
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2006, 231
  • [43] Formation of active species in spark corona discharge at a liquid electrode
    Piskarev, IM
    Solov'ev, GG
    Karelin, VI
    Selemir, VD
    Spirov, GM
    HIGH ENERGY CHEMISTRY, 2005, 39 (03) : 189 - 191
  • [44] Formation of active species in spark corona discharge at a liquid electrode
    I. M. Piskarev
    G. G. Solov’ev
    V. I. Karelin
    V. D. Selemir
    G. M. Spirov
    High Energy Chemistry, 2005, 39 : 189 - 191
  • [45] A STUDY OF CORONA DISCHARGE RATE AND ENERGY LOSS IN SPARK GAPS
    BARTNIKAS, R
    DOMBRAIN, GL
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1965, PA84 (09): : 770 - +
  • [47] DIGITAL MEASUREMENT OF HIGH VOLTAGE IMPULSE CORONA DISCHARGE.
    Arai, Kenji
    Yamamoto, Fumio
    Tsunoda, Yoshihiro
    Memoirs of the Faculty of Engineering, Kobe University, 1982, (28): : 231 - 237
  • [48] Time scanning of impulse discharge spectrum
    Bogdanov, SJ
    Wulfson, KS
    COMPTES RENDUS DE L ACADEMIE DES SCIENCES DE L URSS, 1941, 30 : 311 - 314
  • [49] Surface discharge characteristics of Silicone Rubber Surge Arrester housings with high humidity and pollution
    Giriantari, I.A.D.
    Blackburn, T.R.
    Journal of Electrical and Electronics Engineering, Australia, 2001, 21 (01): : 7 - 12
  • [50] Study on the interaction mechanism of double-blade corona discharge with a large discharge gap
    李丁晨
    李传
    李家玮
    杨文迪
    肖梦涵
    张明
    于克训
    Plasma Science and Technology, 2023, (04) : 115 - 124