Influence of impulse corona discharge on discharge time lag of a surge arrester with a spark gap

被引:0
|
作者
Sakoda, Tatsuyta [1 ]
Kubo, Katsutaka [2 ]
Mizutani, Manabu [2 ]
Chiba, Tomoki [2 ]
Kasuga, Yasunori [2 ]
Fukano, Takato [2 ]
机构
[1] Univ Miyazaki, Miyazaki, Japan
[2] Toshiba Energy Syst & Solut Corp, Kawasaki 2100862, Japan
关键词
Arrester; Spark gap; Discharge time lag; Impulse corona discharge; Triple junction point; PERFORMANCE; AIR;
D O I
10.1016/j.elstat.2022.103783
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
ZnO surge arrester with a spark gap is used for reducing electrical failures in power distribution systems of Japan. The high responsiveness, the low residual voltage, and the stable operating voltage are required for the arresters. However, the discharge time lag generally occurs in a spark gap. In this study, measurements of V -t characteristics and observations of optical emissions from impulse corona discharges generated at a newly designed small step edge on an inclined plane of each electrode were carried out. The small step edge made the discharge time lag and the standard deviation small. Based on the results, we indicated that the impulse corona discharge improves the discharge time lag of the sparkover.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Influence of space charge on air gap discharge under switching impulse
    Zhan, H., 1600, China Machine Press (29):
  • [32] Spark Discharge Inception Voltage under Surge Voltage Application Influenced by Air Gap Length
    Takahagi, H.
    Kawashima, T.
    Hozumi, N.
    Murakami, Y.
    2017 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENON (CEIDP), 2017, : 525 - 528
  • [33] Several physical characteristics of impulse-corona discharge around conductors. Part 2: Onset voltage and delay time of corona discharge
    Gary, C.
    Dragan, G.
    Lungu, I.
    IEE Proceedings A: Physical Science. Measurement and Instrumentation. Management and Education. Reviews, 1992, 1 (0n) : 197 - 201
  • [34] Corona Discharge to Water Surface and Its Transition to a Spark
    Bozhko, Igor V.
    Kondratenko, Igor P.
    Serdyuk, Yuriy V.
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2011, 39 (05) : 1228 - 1233
  • [35] Determination of surge arrester discharge energy using finite element analysis method
    Illias, Hazlee Azil
    Abd Halim, Syahirah
    Abu Bakar, Ab Halim
    Mokhlis, Hazlie
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2015, 9 (06) : 693 - 701
  • [36] CONDITIONS OF SPARK DISCHARGE EMERGENCE IN A LARGE GAP SPARK CHAMBER
    LYUBIMOV, VA
    SIDOROV, IV
    NUCLEAR INSTRUMENTS & METHODS, 1965, 33 (02): : 355 - &
  • [37] GROWTH OF A SPARK DISCHARGE IN A WIDE AIR GAP
    ALEKSANDROV, GN
    SOVIET PHYSICS TECHNICAL PHYSICS-USSR, 1969, 14 (04): : 560 - +
  • [38] On the recovery of a spark gap in a fast discharge circuit
    Biswas, DJ
    Nilaya, JP
    Chatterjee, UK
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (12): : 4242 - 4244
  • [39] Effect of spark gap shape on time lag
    Wan, F.
    Pommerenke, D.
    Shumiya, H.
    Araki, K.
    ELECTRONICS LETTERS, 2013, 49 (13) : 795 - +
  • [40] Numerical analysis of discharge gap related fluctuations in a cylindrical positive discharge corona
    Talib, Kamran Abu
    Naz, Muhammad Yasin
    Ibrahim, Ahmed Ahmed
    Kamran, Kashif
    Ayyaz, Muhammad
    Shoaib, Muhammad
    AIP ADVANCES, 2024, 14 (02)