A review of CONCEPTT study findings including subanalyses in pregnant women using continuous glucose monitoring with type 1 diabetes and their offspring

被引:0
|
作者
Pham, David Q. [1 ,2 ]
Thorsell, Ashley [3 ]
Castorino, Kristin [3 ]
Cobb, Brandon [3 ]
机构
[1] Western Univ Hlth Sci, Coll Pharm, Pomona, CA 91766 USA
[2] Mary & Dick Allen Diabet Ctr Hoag Hosp, Newport Beach, CA 92663 USA
[3] Sansum Diabet Res Inst, Santa Barbara, CA USA
关键词
pregnancy; continuous glucose monitor; type; 1; diabetes; women; OUTCOMES;
D O I
10.1530/EC-23-0407
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The main objective of this article is to provide a comprehensive review of continuous glucose monitor (CGM) use in pregnant women with type 1 diabetes (T1D) from the CONCEPTT study including subanalyses. Literature search was accessed through MEDLINE (1966-September 2023) using the key terms: CONCEPTT, pregnancy, women, T1D, and CGM with limitations set to distinguish human subjects written in English. A total of 17 publications including one main clinical trial and 15 subanalyses have been published to date regarding the use of CGM in pregnant women with T1D which were conducted by a research group identified as the CONCEPTT Collaborative Group. While advances in maternal care have resulted in safer pregnancy for both the mother and child, women with preexisting T1D and pregnancy still experience higher rates of complications both in the short and long term. The use of CGM in pregnancy has not been studied extensively until more recently. The CONCEPTT clinical trial was a landmark study that involved several subanalyses. The main trial proved that CGM use in T1D pregnancy resulted in less hyperglycemia in the third trimester, reduced large for gestational age (LGA, >90th percentile), reduced neonatal intensive care unit admissions lasting longer than 24 h, and reduced neonatal hypoglycemia. Although subanalyses showed a variety of results including 'inconclusive' due to lack of prespecification, it is believed that CGM in T1D during pregnancy is to be recommended and used for overall improved outcomes.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Continuous glucose monitoring in type 1 diabetes
    Nelly Mauras
    Larry Fox
    Kimberly Englert
    Roy W. Beck
    Endocrine, 2013, 43 : 41 - 50
  • [32] Continuous glucose monitoring in type 1 diabetes
    Mauras, Nelly
    Fox, Larry
    Englert, Kimberly
    Beck, Roy W.
    ENDOCRINE, 2013, 43 (01) : 41 - 50
  • [33] Do pregnant women with gestational diabetes need continuous glucose monitoring?
    Shen, Song-Ying
    Zurauskiene, Justina
    Wei, Dong-Mei
    Chen, Nian-Nian
    Lu, Jin-Hua
    Liu, Hui-Hui
    Cazier, Jean-Baptiste
    Xia, Hui-Min
    Qiu, Xiu
    LANCET, 2019, 394 : 77 - 77
  • [34] Comparison of Glycemic Metrics Measured Simultaneously by Intermittently Scanned Continuous Glucose Monitoring and Real-Time Continuous Glucose Monitoring in Pregnant Women with Type 1 Diabetes
    Norgaard, Sidse Kjaerhus
    Mathiesen, Elisabeth Reinhardt
    Norgaard, Kirsten
    Ringholm, Lene
    DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 (10) : 665 - 672
  • [35] Erratum to: CONCEPTT: Continuous Glucose Monitoring in Women with Type 1 Diabetes in Pregnancy Trial: A multi-center, multi-national, randomized controlled trial - Study protocol
    Denice S. Feig
    Elizabeth Asztalos
    Rosa Corcoy
    Alberto De Leiva
    Lois Donovan
    Moshe Hod
    Lois Jovanovic
    Erin Keely
    Craig Kollman
    Ruth McManus
    Kellie Murphy
    Katrina Ruedy
    J. Johanna Sanchez
    George Tomlinson
    Helen R. Murphy
    BMC Pregnancy and Childbirth, 16
  • [36] Continuous Glucose Monitoring Time-in-Range and HbA1c Targets in Pregnant Women with Type 1 Diabetes
    Tundidor, Diana
    Meek, Claire L.
    Yamamoto, Jennifer
    Martinez-Bru, Cecilia
    Gich, Ignasi
    Feig, Denice S.
    Murphy, Helen R.
    Corcoy, Rosa
    DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 (10) : 710 - 714
  • [37] Real-time continuous glucose monitoring in pregnant women with type 1 diabetes at high risk of severe hypoglycaemia
    Mathiesen, E. R.
    Secher, A. L.
    Stage, E.
    Ringholm, L.
    Barfred, C.
    Damm, P.
    DIABETOLOGIA, 2013, 56 : S506 - S506
  • [38] Association of Continuous Glucose Monitoring (CGM)-Derived Parameters with Adverse Pregnancy Outcomes in Pregnant Women with Type 1 Diabetes
    Luo, Sihui
    Ling, Ping
    Ding, Yu
    Zheng, Xueying
    Yang, Daizhi
    Zhou, Yongwen
    Yan, Jinhua
    Weng, Jianping
    DIABETES, 2020, 69
  • [39] Continuous glucose monitoring for the evaluation of gravid women with type 1 diabetes mellitus
    Yogev, Y
    Chen, R
    Ben-Haroush, A
    Phillip, M
    Jovanovic, L
    Hod, M
    OBSTETRICS AND GYNECOLOGY, 2003, 101 (04): : 633 - 638
  • [40] Continuous glucose monitoring for the evaluation of gravid women with Type 1 diabetes mellitus
    Yogev, Y
    Chen, R
    Ben-Haroush, A
    Peled, Y
    Jovanovic, L
    Phillip, M
    Hod, M
    DIABETOLOGIA, 2002, 45 : A296 - A296