Continuous glucose monitoring for the evaluation of gravid women with type 1 diabetes mellitus

被引:56
|
作者
Yogev, Y
Chen, R
Ben-Haroush, A
Phillip, M
Jovanovic, L
Hod, M
机构
[1] Rabin Med Ctr, Dept Obstet & Gynecol, WHO Collaborating Ctr, IL-49100 Petah Tiqwa, Israel
[2] Rabin Med Ctr, Perinatal Div, IL-49100 Petah Tiqwa, Israel
[3] Schneider Childrens Med Ctr Israel, Natl Ctr Childhood Diabet, Inst Endocrinol & Diabet, Petah Tiqwa, Israel
[4] Sansum Med Res Inst, Santa Barbara, CA USA
来源
OBSTETRICS AND GYNECOLOGY | 2003年 / 101卷 / 04期
关键词
D O I
10.1016/S0029-7844(02)02714-X
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
OBJECTIVE: To compare the daily glycemic profile reflected by continuous and intermittent blood glucose monitoring in pregnant women with type I diabetes and to compare the treatment protocols based on the two monitoring methods. METHODS: The study sample consisted of 34 gravid patients at gestational weeks 16 -32, with type 1 diabetes being treated by multiple insulin injections. Data derived from the continuous glucose monitoring system for 72 hours were compared with fingerstick glucose measurements performed 6-8 times per day. During the study period, patients documented the time of food intake, insulin injections, and hypoglycemic events. Data on demographics, gravidity, parity, body mass index, hemoglobin Alc, and fructosamine levels were collected for each patient. RESULTS: An average (+/- standard deviation) of 780 +/- 54 glucose measurements was recorded for each patient with continuous glucose monitoring. The mean total time of hyperglycemia (glucose level greater than 140 mg/dL) undetected by the fingerstick method was 192 +/- 28 minutes per day. Nocturnal hypoglycemic events (glucose level less than 50 mg/dL) Were recorded in 26 patients; in all cases, there was an interval of 1- 4 hours before clinical manifestations appeared or the event was revealed by random blood glucose examination. Based on the additional information obtained by continuous monitoring, the insulin therapeutic regimen was adjusted in 24 patients (70%). CONCLUSION: Continuous glucose monitoring can diagnose high postprandial blood glucose levels and nocturnal hypoglycemic events that are unrecognized by intermittent blood glucose monitoring and may serve as a basis for determining treatment regimens. A large, prospective study on maternal and neonatal outcome is needed to evaluate the clinical implications of this new monitoring technique.
引用
收藏
页码:633 / 638
页数:6
相关论文
共 50 条
  • [1] Continuous glucose monitoring for the evaluation of gravid women with Type 1 diabetes mellitus
    Yogev, Y
    Chen, R
    Ben-Haroush, A
    Peled, Y
    Jovanovic, L
    Phillip, M
    Hod, M
    [J]. DIABETOLOGIA, 2002, 45 : A296 - A296
  • [2] Continuous glucose monitoring in type 1 diabetes mellitus
    Pavlicek, Vojtech
    [J]. DIABETOLOGE, 2019, 15 (08): : 744 - 746
  • [3] Continuous glucose monitoring in type 1 diabetes mellitus
    Tamborlane, William V.
    Beck, Roy W.
    [J]. LANCET, 2009, 373 (9677): : 1744 - 1746
  • [4] Continuous glucose monitoring systems for type 1 diabetes mellitus
    Langendam, Miranda W.
    Luijf, Yoeri M.
    Hooft, Lotty
    DeVries, J. Hans
    Mudde, Aart H.
    Scholten, Rob J. P. M.
    [J]. COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2012, (01):
  • [5] Continuous glucose monitoring and insulin pump therapy in pregnant women with type 1 diabetes mellitus
    Lason, Izabela
    Cyganek, Katarzyna
    Witek, Przemyslaw
    Matejko, Bartlomiej
    Malecki, Maciej T.
    Skupien, Jan
    [J]. GINEKOLOGIA POLSKA, 2021, 92 (10) : 675 - 681
  • [6] Continuous glucose monitoring in pregnant women with type 1 diabetes
    Garg, Satish K.
    Polsky, Sarit
    [J]. LANCET, 2017, 390 (10110): : 2329 - 2331
  • [7] Continuous Glucose Monitoring in Pregnancies Complicated by Type 1 Diabetes Mellitus
    Herrero, Tiffany
    Coleman, Todd
    Laurent, Louise
    Moore, Thomas
    Ramos, Gladys
    [J]. OBSTETRICS AND GYNECOLOGY, 2018, 131 : 125S - 125S
  • [8] The accuracy of continuous glucose monitoring system by the athlete with diabetes mellitus type 1
    Vokounova-Honsova, Sarka
    Navratil, Tomas
    Kohlikova, Eva
    [J]. MONATSHEFTE FUR CHEMIE, 2018, 149 (09): : 1659 - 1669
  • [9] Continuous glucose monitoring: A review of the evidence in type 1 and 2 diabetes mellitus
    Lin, Rose
    Brown, Fran
    James, Steven
    Jones, Jessica
    Ekinci, Elif
    [J]. DIABETIC MEDICINE, 2021, 38 (05)
  • [10] The accuracy of continuous glucose monitoring system by the athlete with diabetes mellitus type 1
    Šárka Vokounová-Honsová
    Tomáš Navrátil
    Eva Kohlíková
    [J]. Monatshefte für Chemie - Chemical Monthly, 2018, 149 : 1659 - 1669