Experimental investigation of an integrated renovation solution combining diffuse ceiling ventilation and double skin façade

被引:1
|
作者
Zhang, Chen [1 ]
Larsen, Olena Kalyanova [1 ]
Hu, Yue [1 ]
Mikkelsen, Asbjorn Kaagaard [1 ]
Pedersen, Lotte Louise [1 ]
Nyborg, Victor Orsoe [1 ]
Larsen, Tine Steen [1 ]
机构
[1] Aalborg Univ, Dept Built Environm, DK-9220 Aalborg, Denmark
关键词
ENERGY PERFORMANCE; BUILDINGS; FACADES; SCHOOL;
D O I
10.1016/j.buildenv.2023.111000
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A novel renovation solution was proposed recently by integrating diffuse ceiling ventilation and double skin facade. This study presents an experimental investigation on the performance of the novel solution in a small-scale classroom. The aim of this study was to evaluate the potential in combining the diffuse ceiling ventilation mode. The performance of the novel solution was compared to a traditional renovation solution installed in an identical room. The results showed that the novel solution achieved comparable or even superior thermal comfort than traditional renovation solution. In winter, the DSF is able to recover the transmission loss through the glazing and capture the heat gain by solar radiation. The heat recovery rate can reach up to 1.2 when solar radiation was strong. In summer, the air ventilated the DSF cavity and served as an air curtain to remove part of the heat gain. Consequently, it reduces the heat gain to the room and maintains lower indoor temperature than the traditional solution. Benefit of the further activation of thermal mass, the novel solution can reduce the peak operative temperature and shift the peak hour to later of the days. Further research is needed to optimize the system's control strategies and integrate solar shading device in the control strategy.
引用
下载
收藏
页数:13
相关论文
共 24 条
  • [11] Exploring the potential of combining diffuse ceiling and double-skin facade for school renovations
    Schaffer, Markus
    Bugenings, Laura Annabelle
    Larsen, Olena Kalyanova
    Zhang, Chen
    BUILDING AND ENVIRONMENT, 2023, 235
  • [12] Integrated solution in an office room with diffuse ceiling ventilation and thermally activated building constructions
    Zhang, Chen
    Heiselberg, Per Kvols
    Pomianowski, Michal
    Yu, Tao
    Jensen, Rasmus Lund
    6TH INTERNATIONAL BUILDING PHYSICS CONFERENCE (IBPC 2015), 2015, 78 : 2808 - 2813
  • [14] Experimental study on the dynamic performance of a novel system combining natural ventilation with diffuse ceiling inlet and TABS
    Yu, Tao
    Heiselberg, Per
    Lei, Bo
    Zhang, Chen
    Pomianowski, Michal
    Jensen, Rasmus
    APPLIED ENERGY, 2016, 169 : 218 - 229
  • [15] Seasonal thermal performance of a macro-encapsulated phase change material blind integrated double skin façade system: An experimental study
    Li, Yilin
    Fu, Sipeng
    Li, Yidong
    Peng, Yuke
    Yang, Caiyi
    Tao, Wanting
    Wang, Haidong
    Energy and Buildings, 2024, 325
  • [16] Experimental investigations on thermal performance of spray cooling double skin fa?ade in hot humid climate region
    Wang, Yanjin
    He, Fangyi
    Lv, Zhihai
    Yang, Weibin
    Wang, Qian
    ENERGY AND BUILDINGS, 2022, 277
  • [17] Evaluation of thermal performance of an elementary school building with the experimental method: Double-skin façade system
    Zeybek, Ozlem
    Manioglu, Gulten
    Koclar Oral, Gul
    MEGARON, 2023, 18 (03): : 328 - 343
  • [19] Naturally ventilated folded double-skin façade (DSF) for PV integration - Geometry evaluation via thermal performance investigation
    Ahmadi, Javad
    Mahdavinejad, Mohammadjavad
    Larsen, Olena Kalyanova
    Zhang, Chen
    Asadi, Somayeh
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2023, 45
  • [20] Evaluation of a Kirigami-inspired double-skin adaptive façade for natural ventilation and solar harvesting to enhance indoor environment and energy performance
    Arauz, Rodrigo
    Filipov, Evgeni
    Fascetti, Alessandro
    Clifford, Dale T.
    Brigham, John C.
    Energy and Buildings, 2024, 324