Semi-Automated Construction of Patient-Specific Aortic Valves from Computed Tomography Images

被引:3
|
作者
Lior, Dan [1 ,2 ]
Puelz, Charles [1 ,2 ]
Edwards, Colin [3 ]
Molossi, Silvana [1 ,2 ]
Griffith, Boyce E. [4 ,5 ,6 ,7 ,8 ,9 ]
Birla, Ravi K. [2 ,10 ]
Rusin, Craig G. [1 ,2 ]
机构
[1] Baylor Coll Med, Dept Pediat, Div Cardiol, Houston, TX 77030 USA
[2] Texas Childrens Hosp, Houston, TX 77030 USA
[3] Rice Univ, Dept Mech Engn, Houston, TX 77005 USA
[4] Univ N Carolina, Dept Math, Chapel Hill, NC 27515 USA
[5] Univ N Carolina, Dept Biomed Engn, Chapel Hill, NC 27515 USA
[6] Univ N Carolina, Dept Appl Phys Sci, Chapel Hill, NC 27515 USA
[7] Univ N Carolina, Carolina Ctr Interdisciplinary Appl Math, Chapel Hill, NC 27515 USA
[8] Univ N Carolina, Sch Med, Computat Med Program, Chapel Hill, NC 27515 USA
[9] Univ N Carolina, Sch Med, McAllister Heart Inst, Chapel Hill, NC 27515 USA
[10] Baylor Coll Med, Div Congenital Heart Surg, Dept Pediat Surg, Houston, TX 77030 USA
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
Aortic valve; Anatomical reconstruction; Fluid-structure interaction; Computed tomography; Immersed finite element; difference method; IMMERSED BOUNDARY MODEL; BLOOD-FLOW; GEOMETRY;
D O I
10.1007/s10439-022-03075-z
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper presents a semi-automatic method for the construction of volumetric models of the aortic valve using computed tomography angiography images. Although the aortic valve typically cannot be segmented directly from a computed tomography angiography image, the method described herein uses manually selected samples of an aortic segmentation derived from this image to inform the construction. These samples capture certain physiologic landmarks and are used to construct a volumetric valve model. As a demonstration of the capabilities of this method, valve models for 25 pediatric patients are created. A selected valve anatomy is used to perform fluid-structure interaction simulations using the immersed finite element/difference method with physiologic driving and loading conditions. Simulation results demonstrate this method creates a functional valve that opens and closes normally and generates pressure and flow waveforms that are similar to those observed clinically.
引用
收藏
页码:189 / 199
页数:11
相关论文
共 50 条
  • [31] Patient-Specific Model Based Segmentation of Lung Computed Tomographic Images
    Sweetlin, Dhalia
    Nehemiah, Khanna H.
    Kannan, A.
    JOURNAL OF INFORMATION SCIENCE AND ENGINEERING, 2016, 32 (05) : 1373 - 1394
  • [32] Patient-Specific Modeling of Heart Valves: From Image to Simulation
    Aggarwal, Ankush
    Aguilar, Vanessa S.
    Lee, Chung-Hao
    Ferrari, Giovanni
    Gorman, Joseph H.
    Gorman, Robert C.
    Sacks, Michael S.
    FUNCTIONAL IMAGING AND MODELING OF THE HEART, 2013, 7945 : 141 - 149
  • [33] Vessel suppressed chest Computed Tomography for semi-automated volumetric measurements of solid pulmonary nodules
    Milanese, Gianluca
    Eberhard, Matthias
    Martini, Katharina
    De Martini, Ilaria Vittoria
    Frauenfelder, Thomas
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 101 : 97 - 102
  • [34] Semi-automated Noninvasive Coronary Plaque Volumetry by 64-Row Multidetector Computed Tomography
    Kijima, Yoshiyuki
    Akutagawa, Osamu
    Sakai, Taku
    Kume, Kiyoshi
    Okura, Akira
    Hata, Takeshi
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (10) : A274 - A275
  • [35] High Precision Semi-Automated Vertebral Height Measurement Using Computed Tomography: a Phantom Study
    Tan, Sovira
    Yao, Jianhua
    Yao, Lawrence
    Ward, Michael M.
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 1554 - 1557
  • [36] Effect of varying computed tomography acquisition and reconstruction parameters on semi-automated clot volume quantification
    Kaufman, Audrey E.
    Pruzan, Alison N.
    Hsu, Ching
    Ramachandran, Sarayu
    Jacobi, Adam
    Fayad, Zahi A.
    Mani, Venkatesh
    WORLD JOURNAL OF RADIOLOGY, 2018, 10 (03): : 24 - 29
  • [37] Patient-Specific Simulation of Cardiac Blood Flow From High-Resolution Computed Tomography
    Lantz, Jonas
    Henriksson, Lilian
    Persson, Anders
    Karlsson, Matts
    Ebbers, Tino
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2016, 138 (12):
  • [38] Semi-automated machines for manufacturing construction materials from plastic waste
    Mohan, H. T.
    Vishnu, R. S.
    Gautham, G.
    Jagadish, G.
    Shambunni, K.
    Shyamlal, S.
    Jayanarayanan, K.
    Mini, K. M.
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-WASTE AND RESOURCE MANAGEMENT, 2023, 176 (02) : 32 - 43
  • [39] Development of cloud services for patient-specific simulations of blood flows through aortic valves
    Kaceniauskas, A.
    Pacevic, R.
    Starikovicius, V.
    Maknickas, A.
    Staskuniene, M.
    Davidavicius, G.
    ADVANCES IN ENGINEERING SOFTWARE, 2017, 103 : 57 - 64
  • [40] Organ localization: Toward prospective patient-specific organ dosimetry in computed tomography
    Segars, W. P.
    Rybicki, K.
    Norris, Hannah
    Frush, D.
    Samei, E.
    MEDICAL PHYSICS, 2014, 41 (12)