Semi-Automated Construction of Patient-Specific Aortic Valves from Computed Tomography Images

被引:3
|
作者
Lior, Dan [1 ,2 ]
Puelz, Charles [1 ,2 ]
Edwards, Colin [3 ]
Molossi, Silvana [1 ,2 ]
Griffith, Boyce E. [4 ,5 ,6 ,7 ,8 ,9 ]
Birla, Ravi K. [2 ,10 ]
Rusin, Craig G. [1 ,2 ]
机构
[1] Baylor Coll Med, Dept Pediat, Div Cardiol, Houston, TX 77030 USA
[2] Texas Childrens Hosp, Houston, TX 77030 USA
[3] Rice Univ, Dept Mech Engn, Houston, TX 77005 USA
[4] Univ N Carolina, Dept Math, Chapel Hill, NC 27515 USA
[5] Univ N Carolina, Dept Biomed Engn, Chapel Hill, NC 27515 USA
[6] Univ N Carolina, Dept Appl Phys Sci, Chapel Hill, NC 27515 USA
[7] Univ N Carolina, Carolina Ctr Interdisciplinary Appl Math, Chapel Hill, NC 27515 USA
[8] Univ N Carolina, Sch Med, Computat Med Program, Chapel Hill, NC 27515 USA
[9] Univ N Carolina, Sch Med, McAllister Heart Inst, Chapel Hill, NC 27515 USA
[10] Baylor Coll Med, Div Congenital Heart Surg, Dept Pediat Surg, Houston, TX 77030 USA
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
Aortic valve; Anatomical reconstruction; Fluid-structure interaction; Computed tomography; Immersed finite element; difference method; IMMERSED BOUNDARY MODEL; BLOOD-FLOW; GEOMETRY;
D O I
10.1007/s10439-022-03075-z
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper presents a semi-automatic method for the construction of volumetric models of the aortic valve using computed tomography angiography images. Although the aortic valve typically cannot be segmented directly from a computed tomography angiography image, the method described herein uses manually selected samples of an aortic segmentation derived from this image to inform the construction. These samples capture certain physiologic landmarks and are used to construct a volumetric valve model. As a demonstration of the capabilities of this method, valve models for 25 pediatric patients are created. A selected valve anatomy is used to perform fluid-structure interaction simulations using the immersed finite element/difference method with physiologic driving and loading conditions. Simulation results demonstrate this method creates a functional valve that opens and closes normally and generates pressure and flow waveforms that are similar to those observed clinically.
引用
收藏
页码:189 / 199
页数:11
相关论文
共 50 条
  • [21] Computed tomography landmark-based semi-automated mesh morphing and mapping techniques: Generation of patient specific models of the human pelvis without segmentation
    Salo, Zoryana
    Beek, Maarten
    Wright, David
    Whyne, Cari Marisa
    JOURNAL OF BIOMECHANICS, 2015, 48 (06) : 1125 - 1132
  • [22] SEMI-AUTOMATED PATIENT SPECIFIC HEXAHEDRAL MESH GENERATION OF ARTICULAR CARTILAGE
    Tadepalli, Srinivas C.
    Shivanna, Kiran H.
    Magnotta, Vincent A.
    Grosland, Nicole M.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2009, PT A AND B, 2009, : 1007 - 1008
  • [23] Semi-automated micro-computed tomography lung segmentation and analysis in mouse models
    Luisi, Jonathan D.
    Lin, Jonathan L.
    Ochoa, Lorenzo F.
    Mcauley, Ryan J.
    Tanner, Madison G.
    Alfarawati, Obada
    Wright, Casey W.
    Vargas, Gracie
    Motamedi, Massoud
    Ameredes, Bill T.
    METHODSX, 2023, 10
  • [24] Construction of gender-specific regression models for aortic length estimation based on computed tomography images
    Zemtsovskaja, Galina
    Pilt, Kristjan
    Samarin, Andrei
    Abina, Jelena
    Meigas, Kalju
    Viigimaa, Margus
    HEALTH AND TECHNOLOGY, 2020, 10 (03) : 679 - 687
  • [25] Construction of gender-specific regression models for aortic length estimation based on computed tomography images
    Galina Zemtsovskaja
    Kristjan Pilt
    Andrei Samarin
    Jelena Abina
    Kalju Meigas
    Margus Viigimaa
    Health and Technology, 2020, 10 : 679 - 687
  • [26] Semi-automated localization of dermal epidermal junction in optical coherence tomography images of skin
    Taghavikhalilbad, Adeleh
    Adabi, Saba
    Clayton, Anne
    Soltanizadeh, Hadi
    Mehregan, Darius
    Avanaki, Mohammad R. N.
    APPLIED OPTICS, 2017, 56 (11) : 3116 - 3121
  • [27] Semi-automated mapping of occluded arterial segments in acute large vessel stroke from computed tomography angiography
    Kannath, Santhosh Kumar
    Anzar, Ajimimol
    Sulaja, Jithin Sivan
    Rajan, Jayadevan Enakshy
    Sylaja, Pn
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2022, 31 (11):
  • [28] Patient-Specific Dosimetry for Pediatric X-Ray Computed Tomography
    Clark, J.
    Stabin, M.
    Pickens, D.
    Price, R.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [29] Patient-Specific Dosimetry for Pediatric X-Ray Computed Tomography
    Clark, J.
    Pickens, D.
    Stabin, M.
    Price, R.
    MEDICAL PHYSICS, 2010, 37 (06) : 3114 - +
  • [30] Semi-automated detection of high-risk carotid artery plaque features from computed tomography angiography
    Gupta, A.
    Al-Dasuqi, K.
    Kamel, H.
    Gialdini, G.
    Baradaran, H.
    Ma, X.
    Johnson, K.
    Paik, D.
    Rosol, M.
    Buckler, A.
    CEREBROVASCULAR DISEASES, 2017, 43