Semi-Automated Construction of Patient-Specific Aortic Valves from Computed Tomography Images

被引:3
|
作者
Lior, Dan [1 ,2 ]
Puelz, Charles [1 ,2 ]
Edwards, Colin [3 ]
Molossi, Silvana [1 ,2 ]
Griffith, Boyce E. [4 ,5 ,6 ,7 ,8 ,9 ]
Birla, Ravi K. [2 ,10 ]
Rusin, Craig G. [1 ,2 ]
机构
[1] Baylor Coll Med, Dept Pediat, Div Cardiol, Houston, TX 77030 USA
[2] Texas Childrens Hosp, Houston, TX 77030 USA
[3] Rice Univ, Dept Mech Engn, Houston, TX 77005 USA
[4] Univ N Carolina, Dept Math, Chapel Hill, NC 27515 USA
[5] Univ N Carolina, Dept Biomed Engn, Chapel Hill, NC 27515 USA
[6] Univ N Carolina, Dept Appl Phys Sci, Chapel Hill, NC 27515 USA
[7] Univ N Carolina, Carolina Ctr Interdisciplinary Appl Math, Chapel Hill, NC 27515 USA
[8] Univ N Carolina, Sch Med, Computat Med Program, Chapel Hill, NC 27515 USA
[9] Univ N Carolina, Sch Med, McAllister Heart Inst, Chapel Hill, NC 27515 USA
[10] Baylor Coll Med, Div Congenital Heart Surg, Dept Pediat Surg, Houston, TX 77030 USA
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
Aortic valve; Anatomical reconstruction; Fluid-structure interaction; Computed tomography; Immersed finite element; difference method; IMMERSED BOUNDARY MODEL; BLOOD-FLOW; GEOMETRY;
D O I
10.1007/s10439-022-03075-z
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper presents a semi-automatic method for the construction of volumetric models of the aortic valve using computed tomography angiography images. Although the aortic valve typically cannot be segmented directly from a computed tomography angiography image, the method described herein uses manually selected samples of an aortic segmentation derived from this image to inform the construction. These samples capture certain physiologic landmarks and are used to construct a volumetric valve model. As a demonstration of the capabilities of this method, valve models for 25 pediatric patients are created. A selected valve anatomy is used to perform fluid-structure interaction simulations using the immersed finite element/difference method with physiologic driving and loading conditions. Simulation results demonstrate this method creates a functional valve that opens and closes normally and generates pressure and flow waveforms that are similar to those observed clinically.
引用
收藏
页码:189 / 199
页数:11
相关论文
共 50 条
  • [1] Semi-Automated Construction of Patient-Specific Aortic Valves from Computed Tomography Images
    Dan Lior
    Charles Puelz
    Colin Edwards
    Silvana Molossi
    Boyce E. Griffith
    Ravi K. Birla
    Craig G. Rusin
    Annals of Biomedical Engineering, 2023, 51 : 189 - 199
  • [2] Semi-automated carotid lumen segmentation in computed tomography angiography images
    Hamid Reza Hemmati
    Mahdi Alizadeh
    Alireza Kamali-Asl
    Shapour Shirani
    TheJournalofBiomedicalResearch, 2017, 31 (06) : 548 - 558
  • [3] The semi-automated design & manufacture of patient-specific intervertebral disc implants
    de Beer, N.
    INNOVATIVE DEVELOPMENTS ON VIRTUAL AND PHYSICAL PROTOTYPING, 2012, : 131 - 138
  • [4] A semi-automated method for patient-specific computational flow modelling of left ventricles
    Vinh-Tan Nguyen
    Loon, Chong Jia
    Hoang Huy Nguyen
    Liang, Zhong
    Leo, Hwa Liang
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2015, 18 (04) : 401 - 413
  • [5] Semi-automated digital workflow to design and evaluate patient-specific mandibular reconstruction implants
    van Kootwijk, A.
    Moosabeiki, V
    Saldivar, M. Cruz
    Pahlavani, H.
    Leeflang, M. A.
    Niar, S. Kazemivand
    Pellikaan, P.
    Jonker, B. P.
    Ahmadi, S. M.
    Wolvius, E. B.
    Tumer, N.
    Mirzaali, M. J.
    Zhou, J.
    Zadpoor, A. A.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2022, 132
  • [6] Semi-Automated Patient-Specific Scalp EEG Seizure Detection with Unsupervised Machine Learning
    Smart, Otis
    Chen, Michael
    2015 IEEE CONFERENCE ON COMPUTATIONAL INTELLIGENCE IN BIOINFORMATICS AND COMPUTATIONAL BIOLOGY (CIBCB), 2015, : 54 - 60
  • [7] Numerical Simulation of Intravascular Ultrasound Images Based on Patient-Specific Computed Tomography
    van Aarle, Daniek A. C.
    Fasen, Floor
    Schmeitz, Harold A. W.
    de Bruijn, Frederik J.
    van Sambeek, Marc R. H. M.
    Schwab, Hans-Martin
    Lopata, Richard G. P.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2025, 72 (02) : 215 - 225
  • [8] Automated and semi-automated procedures in the assessment of Coronary Arterial Disease by Computed Tomography
    Ribeiro, M. M.
    Bate, I.
    Goncalves, N.
    O'Neill, J.
    Mauricio, J. C.
    COMPUTATIONAL MODELLING OF OBJECTS REPRESENTED IN IMAGES: FUNDAMENTALS, METHODS AND APPLICATIONS III, 2012, : 229 - 234
  • [9] Pulsatile hemodynamics in patient-specific thoracic aortic dissection models constructed from computed tomography angiography
    Ko, Jacky Ka Long
    Liu, Ryan Wen
    Ma, Diya
    Shi, Lin
    Yu, Simon Chun Ho
    Wang, Defeng
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2017, 25 (02) : 233 - 245
  • [10] A semi-automated approach for measuring splenic injury using computed tomography
    Danelson, Kerry A.
    Hoth, J. Jason
    Miller, Preston R.
    Stitzel, Joel D.
    Biomedical Sciences Instrumentation, Vol 43, 2007, 43 : 13 - 17