Alignment philosophy influences trochlea recreation in total knee arthroplasty: a comparative study using image-based robotic technology

被引:23
|
作者
Shatrov, Jobe [1 ,2 ]
Coulin, Benoit [1 ]
Batailler, Cecile [1 ]
Servien, Elvire [1 ]
Walter, Bill [3 ,4 ]
Lustig, Sebastien [1 ]
机构
[1] Lyon Univ Hosp, Croix Rousse Hosp, FIFA Med Ctr Excellence, Orthopaed Surg & Sports Med Dept, Lyon, France
[2] Sydney Orthopaed Res Inst Landmark Orthopaed, Sydney, NSW, Australia
[3] Univ Sydney, Sydney, NSW, Australia
[4] Royal North Shore Hosp, Sydney, NSW, Australia
关键词
Total knee arthroplasty; Trochlea; Patellofemoral; Kinematic alignment; Functional alignment; Mechanical alignment; MALROTATION;
D O I
10.1007/s00264-022-05570-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose The ability of kinematic alignment (KA) to consistently restore trochlea anatomy in total knee arthroplasty (TKA) is unknown despite recreation of constitutional anatomy being its rationale for use. The purpose of this study was to assess if alignment choice in TKA effects the ability to restore the native trochlea groove. Methods One hundred and twenty-two consecutive patients undergoing robotic-assisted TKA using the MAKO image-based robotic platform had simulated femoral components placed according to kinematic, mechanical and functional alignment principals. Implant position and trochlea restoration between groups were compared. Restoration was assessed by shift (medial-lateral) and depth relative to the native groove from three consistent points; full extension (0 degrees), mid-flexion (30 degrees-40 degrees) and deep flexion (70 degrees-80 degrees). Results Three hundred and sixty-six alignment options were analysed. Femoral alignment was significantly different between groups. Of KA, 13.1% compared to 3.3% of FA plans were outside safe coronal boundaries. The trochlear groove was translated the most by MA compared to KA and FA (full extension, MA 7.84 +/- 1.99 mm lateral to the native groove, KA 6.40 +/- 2.43 mm and FA 6.88 +/- 1.74 mm, p <= 0.001). In full extension, FA most closely restored the trochlear groove depth in all three positions of flexion. Conclusion Alignment philosophy led to significant differences in trochlea groove recreation. A kinematically placed femoral component led to positioning considered unsafe in over 13% of cases. A functionally placed femoral component most closely restored trochlea depth in all three positions of flexion.
引用
收藏
页码:329 / 341
页数:13
相关论文
共 50 条
  • [1] Alignment philosophy influences trochlea recreation in total knee arthroplasty: a comparative study using image-based robotic technology
    Jobe Shatrov
    Benoit Coulin
    Cécile Batailler
    Elvire Servien
    Bill Walter
    Sebastien Lustig
    International Orthopaedics, 2023, 47 : 329 - 341
  • [2] Individualized alignment in total knee arthroplasty using image-based robotic assistance
    Calliess, Tilman
    Ettinger, Max
    Savov, Peter
    Karkosch, Roman
    Windhagen, Henning
    ORTHOPADE, 2018, 47 (10): : 871 - 879
  • [3] Kinematic alignment in total knee arthroplasty with image-based and image-independent robotic support
    Ettinger, M.
    Tucking, L-R
    Savov, P.
    ORTHOPADE, 2020, 49 (07): : 604 - 610
  • [4] Image-based robotic (ROSA® knee system) total knee arthroplasty with inverse kinematic alignment compared to conventional total knee arthroplasty
    Eijking, Henriette M.
    Dorling, Isobel M.
    van Haaren, Emil H.
    Hendrickx, Roel
    Nijenhuis, Thijs
    Schotanus, Martijn G. M.
    Bouwman, Lee
    Most, Jasper
    Boonen, Bert
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2025, 20 (01):
  • [5] Individualized alignment in total knee arthroplasty using image-based robotic assistance: Video article; [Individualisiertes Alignment in der Knieendoprothetik mit bildbasierter Roboterassistenz: Videobeitrag]
    Calliess T.
    Ettinger M.
    Savov P.
    Karkosch R.
    Windhagen H.
    Der Orthopäde, 2018, 47 (10): : 871 - 879
  • [6] Functional Alignment Philosophy in Total Knee Arthroplasty-Rationale and Technique for the Valgus Morphotype Using an Image Based Robotic Platform and Individualized Planning
    Shatrov, Jobe
    Foissey, Constant
    Kafelov, Moussa
    Batailler, Cecile
    Gunst, Stanislas
    Servien, Elvire
    Lustig, Sebastien
    JOURNAL OF PERSONALIZED MEDICINE, 2023, 13 (02):
  • [7] Image-based robot assisted bicompartmental knee arthroplasty versus total knee arthroplasty
    Thilak, Jai
    Rao, Srivatsa Nagaraja
    Mohan, Vipin
    Babu, Balu C. C.
    SICOT-J, 2022, 8
  • [8] Image-based robotic unicompartmental knee arthroplasty allowed to match the rotation of the tibial implant with the native kinematic knee alignment
    Clément Favroul
    Cécile Batailler
    Robin Canetti
    Jobe Shatrov
    Francesco Zambianchi
    Fabio Catani
    Elvire Servien
    Sébastien Lustig
    International Orthopaedics, 2023, 47 : 519 - 526
  • [9] Image-based robotic unicompartmental knee arthroplasty allowed to match the rotation of the tibial implant with the native kinematic knee alignment
    Favroul, Clement
    Batailler, Cecile
    Canetti, Robin
    Shatrov, Jobe
    Zambianchi, Francesco
    Catani, Fabio
    Servien, Elvire
    Lustig, Sebastien
    INTERNATIONAL ORTHOPAEDICS, 2023, 47 (02) : 519 - 526
  • [10] Image-based robotic total knee arthroplasty preserves the knee joint line level even in advanced fixed flexion deformities when combined with functional alignment principles: A retrospective comparative cohort study
    Pacchiarotti, Giacomo
    Todesca, Alessandro
    Avram, George Mihai
    Longo, Giovanni
    Paolicelli, Domenico
    Gumina, Stefano
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2025,