Alignment philosophy influences trochlea recreation in total knee arthroplasty: a comparative study using image-based robotic technology

被引:23
|
作者
Shatrov, Jobe [1 ,2 ]
Coulin, Benoit [1 ]
Batailler, Cecile [1 ]
Servien, Elvire [1 ]
Walter, Bill [3 ,4 ]
Lustig, Sebastien [1 ]
机构
[1] Lyon Univ Hosp, Croix Rousse Hosp, FIFA Med Ctr Excellence, Orthopaed Surg & Sports Med Dept, Lyon, France
[2] Sydney Orthopaed Res Inst Landmark Orthopaed, Sydney, NSW, Australia
[3] Univ Sydney, Sydney, NSW, Australia
[4] Royal North Shore Hosp, Sydney, NSW, Australia
关键词
Total knee arthroplasty; Trochlea; Patellofemoral; Kinematic alignment; Functional alignment; Mechanical alignment; MALROTATION;
D O I
10.1007/s00264-022-05570-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose The ability of kinematic alignment (KA) to consistently restore trochlea anatomy in total knee arthroplasty (TKA) is unknown despite recreation of constitutional anatomy being its rationale for use. The purpose of this study was to assess if alignment choice in TKA effects the ability to restore the native trochlea groove. Methods One hundred and twenty-two consecutive patients undergoing robotic-assisted TKA using the MAKO image-based robotic platform had simulated femoral components placed according to kinematic, mechanical and functional alignment principals. Implant position and trochlea restoration between groups were compared. Restoration was assessed by shift (medial-lateral) and depth relative to the native groove from three consistent points; full extension (0 degrees), mid-flexion (30 degrees-40 degrees) and deep flexion (70 degrees-80 degrees). Results Three hundred and sixty-six alignment options were analysed. Femoral alignment was significantly different between groups. Of KA, 13.1% compared to 3.3% of FA plans were outside safe coronal boundaries. The trochlear groove was translated the most by MA compared to KA and FA (full extension, MA 7.84 +/- 1.99 mm lateral to the native groove, KA 6.40 +/- 2.43 mm and FA 6.88 +/- 1.74 mm, p <= 0.001). In full extension, FA most closely restored the trochlear groove depth in all three positions of flexion. Conclusion Alignment philosophy led to significant differences in trochlea groove recreation. A kinematically placed femoral component led to positioning considered unsafe in over 13% of cases. A functionally placed femoral component most closely restored trochlea depth in all three positions of flexion.
引用
收藏
页码:329 / 341
页数:13
相关论文
共 50 条
  • [41] An early clinical comparative study on total knee arthroplasty with kinematic alignment using specific instruments versus mechanical alignment in varus knees
    Wen, Liang
    Wang, Zhiwei
    Ma, Desi
    Zhao, Xiaoxiong
    FRONTIERS IN SURGERY, 2023, 9
  • [42] A new gap balancing technique with functional alignment in total knee arthroplasty using the MAKO robotic arm system: a preliminary study
    Tsai, Hung-Kang
    Bao, Zhengyuan
    Wu, Dengxian
    Han, Jing
    Jiang, Qing
    Xu, Zhihong
    BMC SURGERY, 2024, 24 (01)
  • [43] Correction to: No difference in outcomes and gait analysis between mechanical and kinematic knee alignment methods using robotic total knee arthroplasty
    Je-Hyoung Yeo
    Jong-Keun Seon
    Dong-Hyun Lee
    Eun-Kyoo Song
    Knee Surgery, Sports Traumatology, Arthroscopy, 2019, 27 : 2385 - 2385
  • [44] Is sequential bilateral robotic total knee arthroplasty a safe procedure? A matched comparative pilot study
    Batailler, Cecile
    Anderson, Mike B.
    Flecher, Xavier
    Ollivier, Matthieu
    Parratte, Sebastien
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (03) : 1599 - 1609
  • [45] Is sequential bilateral robotic total knee arthroplasty a safe procedure? A matched comparative pilot study
    Cécile Batailler
    Mike B. Anderson
    Xavier Flecher
    Matthieu Ollivier
    Sébastien Parratte
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 1599 - 1609
  • [46] Valgus stress knee radiographs accurately anticipate the bone resection in medial unicompartmental knee arthroplasty: Protocol validation using an image-based robotic system
    Gaggiotti, Stefano
    Foissey, Constant
    Rossi, Valentina
    Batailler, Cecile
    Gaggiotti, Gabriel
    Gaggiotti, Santino
    Servien, Elvire
    Lustig, Sebastien
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2025, 33 (01) : 286 - 295
  • [47] High return to sport rate in patients undergoing image-based robotic arm assisted unicompartmental knee arthroplasty
    Daffara, Valerio
    Zambianchi, Francesco
    Festa, Enrico
    Costantini, Riccardo Cuoghi
    Clemenza, Sebastiano
    Catani, Fabio
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (09) : 4037 - 4044
  • [48] A comparative study of the hemodynamic and clinical effects of using or not tourniquet in total knee arthroplasty
    Hung, Shih-Hsin
    Chiu, Fang-Yao
    Cheng, Ming-Fai
    JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2023, 86 (05) : 529 - 533
  • [49] A comparative study of early postoperative pain: robotic-assisted versus conventional total knee arthroplasty
    Chareancholvanich, Keerati
    Pornrattanamaneewong, Chaturong
    Udompanich, Ronnakit
    Awirotananon, Kit
    Narkbunnam, Rapeepat
    INTERNATIONAL ORTHOPAEDICS, 2025,
  • [50] Clinical and radiographic outcomes of Image-Based Computer-Assisted Total Knee Arthroplasty: An Evidence-based Evaluation
    Cheng, Tao
    Zhang, Gouyou
    Zhang, Xianlong
    SURGICAL INNOVATION, 2011, 18 (01) : 15 - 20